Troubleshooting

Message
BREAKDOWN IN
SENSOR A
BREAKDOWN IN
SENSOR B
SHORT CIRCUIT IN
SENSOR A
SHORT CIRCUIT IN
SENSOR B
DATE/TIME
[the setting flashes]
SETTING: LANGUAGE
– DATE/TIME – OPERA-
TIONAL MODE – SENSOR
OVERTEMP ALARM
[flashing display]
UNDERTEMP ALARM
[flashing display]
OVERHEATING
PROTECTION ACTIVE
Reason
The sensor installed on terminal blocks 5 and 6 is not
connected properly or is damaged.
The sensor installed on terminal blocks 6 and 7 is not
connected properly or is damaged.
The sensor installed on terminal blocks 5 and 6 is not
connected properly or is damaged.
The sensor installed on terminal blocks 6 and 7 is not
connected properly or is damaged.
If the sensor has to be replaced, you can order it from
Ebeco:
High temperature sensor:
Low temperature sensor:
The reserve power has run out if the thermostat
has been without power for more than 50 hours.
This means that the processor running the clock has
stopped and the date and time must be reset. All
other settings are saved in the memory.
Set the date and time so that the thermostat runs as
normal again.
If you forget in the startup menu to make any setting,
you have to go back to the menu and do this before
you can leave the startup mode.
This means that the actual value has exceeded the
set alarm temperature. The thermostat interrupts the
load but it works normally otherwise until the actual
value falls below the set alarm temperature or the
alarm temperature is set above the actual value.
This mean that the actual value has fallen below the
set alarm temperature. The thermostat interrupts the
load but it works normally otherwise until the actual
value rises above the set alarm temperature or the
alarm temperature is set below the actual value.
If the text appears in the display mode, it means that
the actual value in the floor has exceeded the set
temperature for overheating protection. The thermo-
stat interrupts the load but it works normally other-
wise until the actual value falls below the set alarm
temperature or the alarm temperature is set above
the actual value.