How to remove the second RGB module ?
When removing the second RGB module, turn off the projector and unplug the power cord from the wall outlet.
1. Loosen the two bolts on each side of the projector (image 6.8).
2. Lift up the protection plate (image 6.8).
3. The second RGB module is located in the slot 4 of the main frame (image 6.8).
4. Press the module locks (A image 6.8) and lift up the module handles (B image 6.8) on both sides of the module.
5. Disconnect the mini-connector J3 (image 6.8) on the printed circuit board in slot 2, for easy handling, repeat step 4 to lift up this
printed circuit board.
(Remark: when an optional Limo Plus is installed, the mini-connector is connected to the Limo Plus print in slot 3).
6. Extract the module out of the main frame.
7. When finished, reconnect mini-connector J3, secure the printed circuit boards and put back the protection plate.
image 6.8
Removing the second RGB module
75 W Termination resistors
In case of chaining (loop-through) the projectors, the 75W line termination resistors must be removed from the second RGB Input
Module when the projector is NOT the last unit in the chain.
In case of a stand-alone projector, do not remove the resistors.
75 W resistors on the module
75 W resistors removed
Removing the termination resistors
1
Turn off the projector and unplug the projector power cord.
2
Remove the protection plate on top of the electric block.
3
Remove the RGB Input Module from the main frame.
4
Unsolder and remove the resistors.
Blue in green switch
Blue characters are difficult to read, therefore the blue text will be displayed as cyan so that the readability becomes better.
Switch in the ON position
Switch in the OFF position
Warning
Leaving the switch in the ON position will result in abnormal color balance of the projected image.
Force negative sync Switch
Switch in the ON position
Switch in the OFF position
5976397 SPLIT PACK REALITY 909 09112001
:
line terminated.
:
line not terminated.
:
Blue in Green active.
:
Blue in Green disabled.
:
the sync pulses must be negative.
:
the sync polarity will be automatically detected.
Source connections
B
Slot 4
A
Slot 3
Slot 2
J3
Slot 1
6 - 5