Installation setup
Connecting the cable tube to the optical block
The cable tube contains 6 cables, each with his own connector.
Make sure to connect the side with the longest EHT cable (image 4.2) to the optical block.
There is an opening to mount the cable tube in on the right and left side of the block. The unused opening is closed with a protection
plate.
1
Loosen the fastener ring on the side off the cable tube with the longest EHT cable.
2
Put the cable tube connector through the opening, the cable tube can be connected on the right or the left side (image 4.2).
3
Tighten the fastener ring so that the cable tube is secured to the block.
3
Put the EHT cable through the opening at the back of the optical block, inside the projector make sure to guide the cable UNDER
the picture tube unit and connect this cable to the EHT connection on the EHT block (image 4.2).
4
Connect the RGB cables to the BNC connectors on the back of the optical block (image 4.2), the cables and connectors are marked
with their respective colors.
5
Connect the Signal and Data cables to the corresponding connectors on the back of the optical block (image 4.2).
Interchanging of the two 36 pin connectors is prevented by a build_in key in the female connectors.
(When these cables need to be unplugged, push the tabs on the sides of the connector and pull backwards)
6
Put the protection plates back in place.
Connecting the cable tube to the electric block
1
Loosen the fastener ring on the cable tube.
2
Put the cable tube connector through the opening, the cable tube can be connected on the right or the left side (image 4.2).
3
Tighten the fastener ring so that the cable tube is secured to the block.
3
Connect the EHT cable to the EHT connection on the back of the electric block (image 4.2).
4
Connect the RGB cables to the BNC connectors on the back of the electric block (image 4.2), the cables and connectors are marked
with their respective colors.
5
Connect the Signal and Data cables to the corresponding connectors on the back of the electric block (image 4.2).
6
Put the protection plate back in place.
1 EHT connector (longuest cable) to Optical Block
1' EHT connector to Electronic Block
2 RGB BNC connetors
3 Signal/Data connectors
J1: 36 pin plug with white wires
J2: 36 pin plug with green wires
J3: 24 pin plug with gray wires
R
G
B
2
R
image 4.2
Connecting the cable tube
4 - 2
Optical Block
1
J3
J2
J1
3
Electronic Block
G B
J3
J2
J1
2
1'
3
Cable Tube
3
2
2
1
5976397 SPLIT PACK REALITY 909 09112001
3
1'
1

Advertisement