Programming The Relay Module - ADEMCO VISTA-100 Installation Instructions Manual

Commercial fire and burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-100:
Table of Contents

Advertisement

Programming the Relay Module

– 56 –
www.PDF-Zoo.com
4204 RELAY MODULE
SWITCH
POSITION
OFF
ON
0
1
2
ON
3
ON
ON
4
ON
ON
5
ON
ON
4204
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
4-PIN CONSOLE PLUG
EITHER OR BOTH
CAN BE USED
TB1
13
14
15
Figure 12a: 4204 Relay Module
4204 RELAY MODULE
4204CF RELAY MODULE
SWITCH
POSITION
OFF
ON
0
1
2
ON
3
ON
ON
4
ON
ON
5
ON
ON
DIP SWITCH
FOR SETTING DEVICE
ADDRESS AND
ENABLING/DISABLING
TAMPER
COVER TAMPER (REED) SWITCH
4-PIN CONSOLE PLUG
EITHER OR BOTH
CAN BE USED
TB1
13
14
15
16
YEL
DATA IN
FROM CONTROL
BLK
(–) GROUND
GRN
DATA OUT
TO CONTROL
RED
(+) 12VDC; SUPPLIES POWER TO MODULE
CIRCUITRY (INCLUDING NOTIFICATION
APPLIANCE RELAY COILS). CURRENT DRAIN AT
12V IS: 25 mA + (80mA PER ACTIVE OUTPUT)
Figure 12b: 4204CF Relay Module
1. With at least one alpha keypad (6139/6139R) wired and set to a proper
address, temporarily apply power to the control.
2. Enter data field programming mode: (Installer Code + 8 0 0 0) .
3. From data field programming mode, press #93 to display the "ZONE
PROG?" prompt.
firealarmresources.com
4 2 0 4 A D D R E S S S E T T I N G S
("—" means "OFF")
2
3
4
5
6
7
8
9
10
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
RELAY
C
4
NC
TYPICAL
NO
(SHOWN "OFF")
C
RELAY
3
NC
NO
C
RELAY
2
NC
NO
C
RELAY
1
NC
16
NO
YEL
DATA IN
TB2
FROM CONTROL
BLK
(–) GROUND
GRN
DATA OUT
TO CONTROL
RED
(+) 12V
4 2 0 4 C F A D D R E S S S E T T I N G S
("—" means "OFF")
2
3
4
5
6
7
8
9
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
NC
NOTIFICATION
APPLIANCE B
NC
2K EOLR
+
#610-7
POLARIZED
NC
NOTIFICATION
APPLIANCES
NC
NOTIFICATION
APPLIANCE A
2K EOLR
+
#610-7
NC
+
}
POWER FOR
POWER FOR
NC
NOTIFICATION APPLIANCE A,
NOTIFICATION APPLIANCE A,
NOTIFICATION APPLIANCE B
NOTIFICATION APPLIANCE B,
8-28 VDC OR VFW. UP TO 2.4A
TB2
DEPENDING ON BELL CURRENT
8–30VDC OR VFW. UP TO 2.4A DEPENDING
ON BELL CURRENT.
NOTIFICATION APPLIANCE AND
CONSOLE DATA OUTPUTS ARE
POWER LIMITED
11
12
13
14
15
ON
ON
ON
ON
ON
10
11
12
13
14
15
ON
ON
ON
ON
ON
ON
ON
- ALARM POLARITY
SHOWN
- EACH OUTPUT
PROVIDES
STYLE Y
SUPERVISION
- EACH OUTPUT
RATED 1.2A MAX
- USE
NOTIFICATION
APPLIANCES
COMPATIBLE
WITH
NOTIFICATION
APPLIANCE
POWER SUPPLY
VOLTAGE
RATING

Hide quick links: