OUTPUT CONTROL (4204 Relay Module/X-l
O Devices)
General
Information
The 4140XMPT2 suppotts up to 16 relay outputs. These outputs may consist of
relay outputs from the 4204 output relay module (4 relay outputs per module) or
X-1 O device
outputs.
Outputs
can be activated
and deactivated
by
s
predetermined events such as turning on lights in the event of an alarm condition
artdor closing a fire door in the event of a fire alarm condition. Refer to the
PROGRAMMING GUIDE for instructions on programming relay options.
There are many different uses for relays, some of which are shown at the end of
this section.
4204
Relay Module
The 4204 Relay Module has 4 form C (normally open and normally closed
contacts) relays. Each relay can be used independently for different functions.
The 4204 is wired to the control's console terminals 6-9. Use standard 4-
conductor twisted cable (for long wire runs) or the connector supplied with the
4204. Each 4204 should be home run back to the panel, The maximum wire run
length from the panel to the 4204 must not exceed:
Wire Guage
Maximum Length
#22
125 feet
#20
200 feet
#18
300 feet
#16
500 feet
The 4204's DIP switch must be set for a device address and that address must be
enabled in the control's Device Programming mode. (Note that some early units
have only 4 DIP switches,)
Program the output relays using the control's *93 Menu Mode. Refer to the
PROGRAMMING GUIDE for details,
4300
Transformer
&
When using X-1O devices, the 4300 transformer must be used Instead of the
X-1 O Devices
1361
transformer shown on the Summary of Connections diagram. The 4300
provides AC power to the panel and rela~s signals from the p=nel through the
premises AC wiring to X-1Odevices.
*
Run a 3-conductor cable between the 4300 interface and the panel. Splice this
cable to a 4142TR cable as shown in the diagram below. Note that the white and
yellow wires of the 4142TR must be spliced together.
X-1O devices plug into standard AC outlets and can be used to perform various
functions. Be sure to set the proper house and unit IDs when using X-1Odevices.
UL NOTE: X-1O devices and the 4300 are not UL Listed for fire or burglaty
functions and are intended for home automation.
DO TRANSFORMEWINTERFAC
OJI
u
ml
ml
ml
-1
40
-2
:
Datn C.xn
Ii
56
I
I
I
J8 CONNECTOR
~
4142TR CASLE