HYDROK
Installation
6.
Screw in the product fixing screws and tighten them gen-
tly.
7.
Unfasten and remove any lifting gear that may have
been required.
8.
Remove the mounting aid on a vertically suspended
spindle if one was used.
9.
Check the position of the product relative to the position
of the test surface [ideally ≤ 0.01 mm] and, if necessary,
correct carefully with a plastic hammer.
10. Tighten the product fixing screws to the specified tight-
ening torque [see »Screw tightening torques« chapter].
11. Check face run-out on the test surface of the product
[ideally ≤ 0.01 mm].
If the face run-out is greater than the maximum permitted
value:
Order hotline +49 7144.907-333
71