Hainbuch HYDROK 32 Operating Instructions Manual page 82

Hydraulic stationary chuck
Table of Contents

Advertisement

HYDROK
Commissioning
82
NOTE
Damage to components caused by cooling lubri-
cants with sufficient levels of corrosion inhibitor!
The components made of steel materials must be
protected before the usual oxidation process.
Only ever use cooling lubricants with sufficient
levels of corrosion inhibitor.
NOTE
Damage to materials caused by contaminated /
unprocessed cooling lubricants!
For the product to function properly, in particular
for internal flushing with cooling lubricants and/or
when using tools with internal flushing, ensure
that the cooling lubricant is cleaned / processed,
and that it contains no particles measuring >100
microns [filtered with a mesh width of 100 mi-
crons].
NOTE
Damage to seals caused by using the wrong cool-
ant lubricants!
To clean the product, never use a cooling lubri-
cant that attacks and damages the sealing ele-
ments installed. Those installed sealing elements
can be made of NBR, Viton and PUR materials.
Never use cooling lubricants that contain ester or
a polar solvent.
NOTE
Damage to clamping elements caused by using
the wrong cooling lubricants!
Never use cooling lubricants that contain ester or
a polar solvent.
Order hotline +49 7144.907-333

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hydrok 42Hydrok 52Hydrok 65Hydrok 80Hydrok 100

Table of Contents