Example Measuring The Horizontal Angle Between Two Points - Kolida KTS-442UT Series Manual

Table of Contents

Advertisement

· To measure the included angle between two points, the horizontal angle can be set to 0 at any direction.
PROCEDURE
Operating Procedure
⑴ Press FNC on the first page of the "MEAS
Mode Screen".
Press 0SET, then 0SET flashes ON and OFF.
⑵ Press 0SET again, the horizontal angle of the
collimation direction is 0°00'00".

8.1.1 Example Measuring the Horizontal Angle between Two Points

PROCEDURE
Operating Procedure
⑴ Using the horizontal clamp and the horizontal
tangent screw, sight the backsight point. From the
MEAS mode, page 2 menu, press 0SET, 0SET
will flash, so press 0SET again, set the back sight
direction to 0.
34
Operation
FNC
+
0SET
0SET
(1)
Operation
0SET
+
0SET
Display
Meas.
ZA
92°36'25"
HAR
120°30'10"
SD
SHV
HSET
Meas.
ZA
92°36'25"
HAR
0°00'00"
OSET
CRD.
S-O
(2)
Display
Meas.
ZA
89°59'25"
HAR
0°00'00"
OSET
CRD.
S-O
PC
-30
PPM
0
5
P2
EDM
PC
-30
PPM
0
5
P2
REC.
PC
-30
PPM
0
3
P2
REC