Example Measuring Horizontal Angle Between Two Points - Kolida Total Station KTS-462R10L Manual

Table of Contents

Advertisement

PROCEDURE
Operating Procedure
1) Press 0SET on the first page of the "MEAS
Mode Screen".
It asks "0SET H Angle?"
2) Press F3 YES, the horizontal angle of the
collimation direction is set to 0°00'00".
8.1.1 Example Measuring the Horizontal Angle between Two Points
PROCEDURE
Operating Procedure
1) Using the horizontal clamp and the horizontal
tangent screw, sight the backsight point. From the
MEAS mode, page 1 menu, press 0SET, then press
YES , set the back sight direction to 0.
2) Sight the foresight point, the displayed (HAR)
value is the included angle between 2 points.
Operation
0SET
Press F3
YES
(1)
Operation
0SET
Sight
Foresight
Point
www.kolidainstrument.com
MEAS(1/3)
0SET H Angle?
MEAS(1/3)
SHV
S
H
V
VA
HAR
DIST
D/C
(2)
MEAS(1/3)
SHV
S
H
+
V
F3
VA
HAR
DIST
D/C
MEAS(1/3)
SHV
S
H
V
VA
HAR
DIST
D/C
Display
YES NO
273°18'15"
0°00'00"
0SET
HSET
Display
0°00'00"
0°00'00"
0SET
HSET
0°00'00"
60°00'21"
0SET
HSET
31