Charging Voltage; Charging Current - Hama 136686 Operating Instructions Manual

Automatic battery charger
Hide thumbs Also See for 136686:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
6.6 Recover 12 volt
Warning – Only for 12-volt lead-acid batteries
• Use the Recover mode solely for 12-volt lead-acid batteries
(liquid electrolyte, gel, maintenance-free (MF), AGM) that
are already aged and no longer fully functional!
• New and fully functional 12-volt batteries can be damaged
through the Recover mode.
• In Recover mode, there may be increased escape of
explosive gases from the battery. Avoid sparks, heat and
fire in close proximity, and run the Recover mode only in
well-ventilated spaces.
• Never use the Recover mode for 6-volt batteries! As a
faultless 6-volt battery can also be detected as a deeply
discharged 12-volt battery, the 12-V Recover mode can be
inadvertently set. These batteries are overcharged with the
high charging voltage and damaged.
• Never use the Recover mode for 12.8-volt 4-cell LiFePO
batteries! These batteries are overcharged with the high
charging voltage and damaged.
Depending on the degree of ageing and chemical degradation,
this charging programme CAN regenerate a deeply discharged
lead-acid battery to a certain extent.
• Press and hold the MODE selection button (1) as described
in Point 6.5, to select the Recover 12 V charging programme.
• If the battery is too damaged and cannot be recovered (no
increase in voltage to 12 V within 3 hours), the fault symbol (F)
flashes and the charger ends the Recover programme (Standby).
• Promptly obtain a replacement battery from a specialist retailer.
7. Care and Maintenance
Note
Disconnect the device from the power supply before cleaning
it or if it is not going to be used for a long period of time.
• Only clean this product with a slightly damp, lint-free cloth
and do not use aggressive cleaning agents.
• Make sure that water does not get into the product.
8. Warranty Disclaimer
Hama GmbH & Co KG assumes no liability and provides no
warranty for damage resulting from improper installation/
mounting, improper use of the product or from failure to
observe the operating instructions and/or safety notes.
9. Technical Data
Supply voltage
Output
Rated output voltage
Rated output current

Charging voltage

Charging current

4
Battery types
IP rating
220–240 V ~ 50 /60 Hz 0.6A
56 W
6V DC / 12V DC / 12.8V DC
0.9 A / 4.0 A / 3.0A
6-V battery: 2–7.3 V /
12-V battery: 7–14.6 V
Lithium battery (12.8-V 4-cell
LiFePO
): 11.6–14.5 V
4
0.9 A ± 10 %, 4.0 A ± 10 %,
3.0 A ± 10 %
6-V lead-acid battery
12 Ah – 120 Ah
12-V lead-acid battery
1.2 Ah – 120 Ah
Lithium battery (12.8-V 4-cell
LiFePO
) 8–50 Ah
4
IP65 (protection against dust
and water spray)
5