Calibration And Setup - NOYAFA NF-868 Instruction Manual

Multipurpose lcd display cable test & inspection instrument
Hide thumbs Also See for NF-868:
Table of Contents

Advertisement

Your wiring expert

Calibration and setup

After powering the main tester and entering the main test menu, press "UP",
"DOWN" key to move cursor
press "ENTER" key to perform calibration and setup function. The following
interface will be shown:
Type selection:
1). Type: twisted-pair cable
Set 5E, 6E type twisted pair cable: when cursor
press "ENTER" key till twisted-pair type is shown, and move the cursor
to"Back" item, press "ENTER" key to return to the main menu.
2). Type: telephone cable
Set telephone cable: when cursor "
key till telephone cable type is shown, and move the cursor "
press "ENTER" key to return to the main menu.
3).Type: USB cable
Set USB cable: when cursor "
USB cable type is shown, and move the cursor "
"ENTER" key to return to the main menu.
4). Type: BNC coaxial cable
Set BNC coaxial cable: when cursor "
key till BNC coaxial cable type is shown, and move the cursor "
item, press "ENTER" key to return to the main menu.
"
"
to "Parameter configuration" item, and then
Type: PAIR(8)
U n i t : M e t e r
C a l i b r a t i o n
R e t u r n
" moves to "Type" item, press "ENTER"
" moves to "Type" item, press "ENTER" key till
" moves to "Type" item, press "ENTER"
-18-
"
"
moves to "Type" item,
" to "Back" item,
" to "Back" item, press
" to "Back"
"
"