ADLINK Technology EOS-JNX-I User Manual page 13

Edge ai vision inference system
Table of Contents

Advertisement

Model
DC Input
Fail Reset
PoE Switch
Dimensions
Weight
Mounting
Operating
Temperature
Storage
Temperature
Humidity
Vibration
Shock
ESD
EMC
Safety
Models in this manual are investigated to IEC TR 62102 as
ES1 and SELV circuits and only connected to PoE without
routing to the outside plant, including campus environments..
WARNING:
Avertissement: Les modèles de ce manuel sont étudiés selon
IEC TR 62102 en tant que circuits ES1 et SELV et uniquement
connectés à PoE sans routage vers l'installation extérieure, y
compris les environnements de campus.
Introduction
EOS-JNX-I
Power
Reset and Recovery buttons
PoE initial mode setup
Mechanical
187.5(W) x 149.5(D) x 55.25(H) mm
supports wall mount & DIN rail mount
Environmental
Standard: -20°C to 50°C (w/ 0.6m/s airflow)
PoE full load and Xavier NX @ max. 20W: max. 50°C
PoE full load and Xavier NX @ max. 15W: max. 60°C
PoE full load and Xavier NX @ max. 10W: max. 70°C
40% to 95% (non-condensing)
Operating: 5-500 Hz, 5 Grms, 3 axes
Operating: 11ms duration, 30G, half sine, 3 axes
Contact +/- 4kV, Air +/- 8kV
CE and FCC Class A (EN61000-6-4/6-2)
UL(62368) and CB
Table 1-1: Specifications
EOS-JNX-G
DC 12 to 24V
1.85 kg
-40°C to 85°C
EOS-JNX Series
3