Intended use and settings Intended use The ZC3C control panel is engineered to command industrial sliding gate operators of the C-BX and F4000 series, 230 V powered. Every installation and use other than that specified in this manual is forbidden.
Dimensions, centre distances and anchoring holes CAME APRE CHIUDE 215 mm 165 mm 240 mm 8 Main components 1 Connecting terminals 2 5 A line fuse 3 1 A accessories fuse 4 24 V power on LED warning light 5 Working time adjuster trimmer...
Installation Preliminary checks Before beginning to install, the following is necessary: Make sure that the point where the electrical panel is anchored is free from any impacts, and that the surface is solid and that proper tools and materials are used (i.e. screws, wall plugs, etc.). Set up a suitable omnipolar cut-off device, with distances greater than 3 mm between contacts, with sectioned power source •...
5) Snap the cover onto the hinges. 6) After adjusting and setting, secure the cover using the issued screws. CAME APRE CHIUDE Electrical connections Gearmotor Single Phase 230 V AC motor C-BX F4000 Limit switches installed: FA-F = Limit switch opens (contact N0);...
Page 6
Lighting and warning devices Cycle /Courtesy lamp Contact rated for: 230 V - 60 W Max.): Cycle lamp_lights up the parking area and stays on from the moment the sliding gate starts opening unitl it is fully closed 16 OFF - 17 ON (including the automatic closing time).
Page 7
Contact (N.C.) for “re-opening during the closing” Input for safety devices like photocells, sensitive edges and other devices that comply with EN 12978 regulations. While (С1) the door is closing, opening the contact will invert movement until it is fully openend. (Contact (N.C.) for “reclose while opening”...
Activating the radio command Antenna Possible second channel output of the Connect RG58 antenna cable to the B1 B2 radio receiver (N.O.) contact apposite terminals. Contact rated for: 5 A-24 V D.C. Trasmettitori ATOMO see instruction sheet in AF43SR radiofrequency AT01 •...
Page 11
Plug in the radio-frequency card onto the electronic board AFTER CUTTING OFF THE MAIN POWER SUPPLY (and disconnecting the emergency batteries). N.B.: The electronic board recognises the radio-frequency card only when it is powered up. + AUT.CL. - + AUT.CL. - + PAR.OP.
On its premises, CAME S.p.A. implements an Environmental Management System certified in compliance with the UNI EN ISO 14001 standard to ensure environmental protection. Please help us to safeguard the environment. At CAME we believe this to be one of the fundamentals in its market operations and development strategies. Just follow these short disposal instructions: DISPOSING OF THE PACKAGING The components of the packaging (i.e.