CAME ZCX10 Manual

CAME ZCX10 Manual

230v control board for c-bxe gearmotors
Hide thumbs Also See for ZCX10:

Advertisement

AUTOMATIC GATES
CBX
CONTROL BOARD FOR
CONTROL BOARD
ZCX10
LINE FUSE 3.15A
A
F C FA F
230V control board
for C-BXE gearmotors
ZCX10
CONTROL BOARD FUSE
ACCESSORIES FUSE
PROGRAMMING FUNCTION
1 A
1A
ESC
<
RSE
B G N D
+
E
-
1 0 1 1 1
2
�� 4
5
7
�� �
T S
>
ENTER
R700
AF
Documentazione
Tecnica
T69
rev. 0.4
03 /2006
©
CAME
CANCELLI AUTOMATICI
319T69-GB

Advertisement

Table of Contents
loading

Summary of Contents for CAME ZCX10

  • Page 1 Documentazione Tecnica AUTOMATIC GATES CONTROL BOARD FOR rev. 0.4 ZCX10 03 /2006 © CAME CANCELLI AUTOMATICI 319T69-GB CONTROL BOARD FUSE ACCESSORIES FUSE PROGRAMMING FUNCTION < > ENTER CONTROL BOARD ZCX10 LINE FUSE 3.15A B G N D R700 F C FA F 1 0 1 1 1 �...
  • Page 2: Legend Symbols

    2 Intended use and use limits 2.1 Intended use The ZCX10 electric board has been designed for the CBX E automation control of sectional-, sliding- and industrial swing gate movement. Any use other than the above, and installations with procedures different to those in the following technical manual, are forbidden.
  • Page 3: Board Description

    3.3 Board description CONTROL BOARD FUSE ACCESSORIES FUSE PROGRAMMING FUNCTION < > ENTER CONTROL BOARD ZCX10 LINE FUSE 3.15A B G N D R700 F C FA F 1 0 1 1 1 � �� 4 �� � Connector for R700 board...
  • Page 4: Installation

    3.4 Assembling hinge housing 15 mm~ Assemble the spring-type hinges, insert the hinges into the housing (on the) left or right as preferred) and secure with the screws and washers supplied they flow for rotating Snap the cover over the hinges, then close and secure it using the screws supplied 4 Installation 4 .1 Preliminary checks...
  • Page 5: Electrical Connections

    4.3 Electrical connections 230V power supply Single phase 230V A.C motor max capacity: 600 W Condenser 20µF 420V. 230V AC Output 25W max. (in movement) for flashing lamp Serial communication for PC connection, use bipolar shielded cable mod. RS235 B GND PC 40 o PC30 Personal RS232 cable...
  • Page 6 4.3 Electrical connections 10 11 CX CY TS (2.4) Close pushbutton Normally Open (N.O.) 10 11 CX CY TS (2.7) Stepper contact, Normally Open sequence CX CY TS 10 11 (10.5) Pilot light Opens 24V 3W 10 11 CX CY TS (10-11) output 24V A.C.
  • Page 7 4.3 Electrical connections DOC and DIR photoelectric cell TEST 10 2 TX C NC Tx 2 10 11 1 3p 3 CX CY TS 10 11 1 3p 3 CX CY TS (S1-GND) connection sensory TSP00 (trasponder) LT001 (creeping) N.B. to make to recognize the sensors to the card, needs to connect the special card of coding (R700).. R700 LT001 R700...
  • Page 8 - entering the menu PROGRAMMING FUNCTION PROGRAMMING FUNCTION - confirming and saving the default value < > ENTER The ESC button is used for: < WWW.CAME.IT > < > LANGUAGE LINGUA - quitting the menu - cancelling changes < >...
  • Page 9 5.3 Menu structure Press ENTER for 1 second ENTER ENTER Select Languag LANGUAGE ENTER > ENTER TIMING Italian ENTER < 10 sec > Operation Time > > < > Englisch ENTER Auto Clo Time < 10 sec > > > <...
  • Page 10 5.4 Menu items Language Language selection: select the language required. Select Languag. ENTER LANGUAGE ENTER > > Englisch French Italian > > > > Dutch Spanisch German Times Work time: Time of motor operation in the single opening/closing phase ENTER Operation Time TIMING ENTER...
  • Page 11 5.4 Menu items Person Present (Dead Man): Enables/disables person-present function. > ENTER Dead Man FUNCTIONS < > ENTER <ON > <OFF> Pres. during closing.(Dead man Clos): Enables/disables the ‘Person present during closing’ function. > ENTER Dead Man. Clos FUNCTIONS ENTER <ON >...
  • Page 12 5.4 Menu items Radio/Users New User: Creates new users > ENTER Add New User RADIO/USER To see detailed description Change User: For changing the functions associated to the user. Edit User RADIO/USER > ENTER To see detailed description Remove user: Removes a user from the system. Delete User ENTER >...
  • Page 13: Run Calibration

    INFO Version: Displays the Software version Number of manoeuvres: Displays the number of manoeuvres carried out.. Start-up Msg.: Sets the start-up message on the display. > ENTER Welcome Note INFO To see detailed description 5.5 Run calibration Perform a complete opening run Then confirm with ENTER.
  • Page 14: Adding Users

    CONTROL BOARD FUSE ACCESSORIES FUSE PROGRAMMING FUNCTION R700 CANCELLI AUTOMATICI < > ENTER CONTROL BOARD ZCX10 LINE FUSE 3.15A B G N D R700 F C FA F 1 0 1 1 1 � �� 4 �� � 5.7 Adding users.
  • Page 15 ENTER < > ENTER Move around as described above until you obtain the desired message,remembering that the maximum number of char- acters is 42 (16 per line). after finishing writing the message, press ENTER for at least 3 secs. WWW.CAME.IT...
  • Page 16: Electrical Characteristics

    Max no. of codes that can be saved: 250 Control systems Supports CAME 12/18/24 BIT radio and Rolling Code systems (the radio system requires the installation of an HF interface while for Rolling Code an HF43S is enough). And 125 Khz trasponder systems (TSP00).