Page 2
4 Description 4.1 Gearmotor The BK-BKE gearmotor is designed and built by CAME CANCELLI AUTOMATICI S.p.A. and it meets the safety standards in force. Guaranteed 24 months if not tampered with. The case consists partly of cast aluminium, inside of which operates the non-reversible electromechanical gearmotor, and partly of a covering in ABS plastic inside of which is an electronic card and the transformer.
Page 3
4.3 Parts description GEARMOTOR UNIT 1 - Gearmotor 2 - Board cover support 3 - End-stop flaps 4 - ZBK-ZBKE basic control board 5 - Electric board front cover 6 - Release door 7 - Base plate 8 - Securing screws 9 - Plates for securing screws 10 - Nuts ACCESSORIES...
Page 4
5 Installation Only expert, qualified personnel must carry out the installation, in full compliance with the applicable law. 5.1 Preliminary checks Before actually installing the gate operator, your are required to: • Check that the leaf is rigid and compact and that the rollers are in good working order and properly greased; •...
Page 5
1- BK or BKE unit 6- Key-operated selector switch 2- Control board incorporated 7- Flashing light indicating door movement 3- Radio receiver 8- Antenna 4- Limit-switch tabs (only for the BK unit) 9- Safety photocells 5- Rack 10- Photocell column 11- Closure stop 5.4 Motor to base anchorage The following applications are only examples, as the space required for unit installation and the accessories vary de-...
Page 6
5.5 Unit installation During the initial phase of installation, the feet should protrude by 5-10 mm. in order to allow for alignment, anchorage of the rack and further adjustments. Perfect alignment with the guide rail is made possible by the (paten-ted) built-in regulation system, which consists of: - slots for horizontal adjustment;...
Page 7
5.7 Attaching the switch tabs (BK series) Position the limit-switch tabs (whose positions determine the limits of gate travel) on the rack. Note: do not allow the gate to strike the mechanical stops in the open or closed positions. 5.8 Manual release of the gearmotor To open the access door, insert the key A, push down and rotate clockwise.
6 Control board 6.1 Technical description The control board is powered with (120V a.c. or 230V a.c.) across terminals L and N and is protected by fuse on the main power line (see table). The control systems are powered by low voltage (24V) and protected by a 1A fuse. The total power consumption of the 24V accessories must not exceed 20W.
Page 9
6.3 Electrical connections Connection for gear motor, limit switch or encoder ZBKE (Condenser) Connection for the limit switch unit (BK series) Output for 230V (a.c.) Connection for motor con- encoder (BKE nection series) Modifications to the connection if installing the gear motor on the right side - Invert the phases of the gear motor (U;...
Page 10
Connections to the systems Stop button (N.C. contact) – Gate leaf stop- button with exclusion of automatic closing phase, resume motion by pressing the push button or remote control. Key selector and/or opening button (N.0. contact) – Opens the gate leaf. Key selector and/or partial opening button (N.0.
Page 11
Connections to safety devices (DIR photocell) Set power supply to 24V a.c./d.c. (N.C.) contact for “re-opening during closing” – Input for safety devices such as photocells, sensiti- ve safety edges and other devices compliant with EN 12978 standards. When the gate leaf is closing, ope- ning the contact triggers the inversion of the direction of movement until the gate leaf is fully open.
Page 12
6.4 Electrical connection for the check of the operating state of the photocells Each time an open or close command is given, the circuit board checks the efficiency of the safety devices (i.e. photocells). The flashing led indicator on the control panel indicates an anomaly of the photocells (Ref.
Page 13
6.7 Selecting functions (dip-switch) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 ON - Automatic Closing – the automatic closing timer is automatically triggered at the end of the opening phase. The adjustable set time of operation, is in any case subordinate to the operation of any safety accessories and is exclu- ded after a total “stop”...
Page 14
7 Programming of limit switches for ZBKE board 1) Close the engage door-panel and insert DIP switch 15 to the ON position, the led indicator of the radio code starts flashing. 2) Manually close the gate leaf, press the “CLOSE” button, the led indicator keeps flashing as long as button is kept pressed.
Page 15
8 Connection of two coupled gear motors with single control 1) Coordinate the direction of gear motors “A” and “B”, by changing the rotation of motor “B” (see con- nection for the gear motor and limit switches, p. 9). 2) Establish which motor, “A” or “B”...
Page 16
9 Installation procedure of the transmitter for remote control Input for the remote control’s antenna Possible second channel – For opening and closing of the gate output from the radio receiver leaf using the remote control. Con- (contact N.O.) Contact ou- nect the RG58 cable to the terminal of tput: 5A-24V (d.c.).
Page 17
9.2 Procedure for codifying the transmitter TOP SERIES T432M - T312M set the code to dip-switch C and channel to D (P1=CH1 and P2=CH2, default setting) T432S - T432SA - T434MA - T432NA - T434NA T434M - T314M see instructions on pack set code only P1 = CH1 P2 = CH2...
Page 18
TOP QUARTZ SERIES Standard encoding procedure T262M - T264M - T2622M - T302M - T304M - T3022M 1 assign a code (also on file) 2 connect encoding jumper J Press P1 or P2 in sequence in order to register the code;...
Page 20
9.3 Memorizing the code on the command board CH1 = Channel for direct commands to a function of the ratiomotor control unit (“open only” / “open-clo- se-invert direction” commands or the “open-stop-close-stop” command, depending on dip-switch 2 - 3 settings). 1) Keep the "CH1"...
Page 21
UNI EN ISO 14001 standard to ensure environmental protection. Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development of its operational and market strategies—simply by observing brief recommendations as regards disposal: DISPOSAL OF PACKAGING –...
Need help?
Do you have a question about the BK 800 and is the answer not in the manual?
Questions and answers