  • Page 2 IMPORTANT UL-325 SAFETY INSTRUCTIONS AX3024U/ AX5024U It is extremely important that all parties involved in the installation and operation of the gate operator system read and understand the following warning instructions. WARNING – To reduce the risk of injury or death: 1.
  • Page 3 F. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.22m) above the ground to prevent a 2-1/4 inch (57.2mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
  • Page 4 CAME® to be defective, and is conditioned upon CAME® receiving notice of any such defect within the warranty period. Claims under this warranty may only be made by a purchaser of CAME®...
  • Page 5: Power Connection

    Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. CAME®‘s liability will be no more than the amount you paid for the product that is the subject of a claim.
  • Page 6: Legend Of Symbols

    * The electrolock must be installed onto the door-leaf. 3 Reference Standards The company CAME cancelli automatici is ISO 9001:2000 quality certified; it has also obtained the ISO 14001 environmental safeguarding certification. CAME engineers and manufactures all of its products in Italy.
  • Page 7: Technical Features

    4.2 Technical features 131 F GEARMOTOR AX3024U / AX5024U 131°F Control board power supply: 120V A.C. 50/60Hz -4°F Motor power supply: 24V D.C. -4 F Max draw.: 10A Power: 240W Adjustable thrust: 500 - 4500N Opening time (90°): adjustable Duty cycle: intensive user Protection rating: IP44 Operating temperature: -4ºF - 131ºF...
  • Page 8: Installation

    5 Installation Installation must be carried out by expert qualified personnel and in full compliance with current regulations. 5.1 Preliminary checks Before installing, do the following: • Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage.
  • Page 9: Standard Installation

    5.4 Standard installation 1) AXO operator 2) Control panel 3) Reception antenna 4) Flashing light 5) Selector switch 6) Photocells 7) Electric cable junction box 8) Mechanical gate stops 9) Photocell column 5.5 Installing the operator The following illustrations are only examples, given that the space available for anchoring the operator and accessories may vary from gate to gate.
  • Page 10 Warning: After establishing the best point to which you will secure the gate bracket, secure the bracket to the pillar and make sure the quotas shown in the table below are met. Note: By increasing measure B, the opening angle and gate speed are reduced, while the gearmotor thrust is increased. By increasing the measure A, the opening angle and gate speed are increases, while the gearmotor thrust is decreased.
  • Page 11 Weld the gate bracket to the gate leaf making sure the quotas shown in the table are met. Note: for AX5024U gearmotors, require an additional 10 mm shim between the gate and the bracket. Note: On non-metal gate leaves assemble and weld the two parts of the bracket and secure them with proper screws.
  • Page 12 Open the gate leaf and insert the pin into the gate bracket and secure it using a washer and nut. Gate bracket UNI6593 Ø8 washer Screw UNI5739 M8x10 Release the gearmotor (see paragraph on manual release), completely open the gate leaf, loosen the nuts of the opening mechanical stop and position it up against the attachment pin, then secure it.
  • Page 13: Connecting To The Control Panel

    5.6 Manual release of the gearmotor Slide open the small door that protects the release, insert the tri-lobed key and turn it. 5.7 Connecting to the control panel For the electrical connection procedures, use the junction box and branching boxes. Connecting the 24V d.c.
  • Page 14 5.8 Outward opening installation (non-issued) Supplementary bracket TABLE 1 TABLE 2 Opening Opening (in) (in) (in) (in) (in) (in) 90° 43.3 90° 5.11 5.11 31.5 Weld pillar bracket to the non-issued supplementary bracket, while gate is open, then secure the brackets to the pillar, making sure the “A”...
  • Page 15 Fully close the gate-leaf, place the mechanical stop against it with the pin attachment and fi x it in place. Attachment pin Opening mechanical stop Fully open the gate-leaf, place the mechanical stop against it with the pin attachment and fi x it in place. Attachment pin Closing mechanical stop Connect the gearmotors to the panel as shown in the diagram.
  • Page 16: Safety Instructions

    6 Safety instructions Important safety instructions This product must only be employed for its originally intended use. The automation installation using these gearmotors requires adequate safety systems on the gate leaves to detect any obstacles (e.g. sensitive edges), in compliance with UL325 standards and CSA C22.2 No.247 for both the US and Canada.
  • Page 17: Periodic Maintenance

    7 Maintenance 7.1 Periodic maintenance Periodic maintenance to be carried out by the end-user is as follows: wipe clean the glass surface of the photocells; check that the safety devices work properly; remove any obstructions. We suggest checking the state of lubrication and tightness of the anchoring screws on the operator. To check the efficiency of the safety devices, move an object in front of the photocells when gate is closing.
  • Page 18: Extraordinary Maintenance

    Periodic maintenance log for end-user (every 6 moths). Date Notes Signature 7.3 Extra-ordinary maintenance The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised firms. Note: Any extraordinary maintenance must be performed by specialised technicians. Extraordinary maintenance log Installer’s stamp Operator name...