Technical Data - Siemens SITRANS F C MC2 Operating Instructions Manual

Coriolis flowmeters
Table of Contents

Advertisement

Technical data

Versions
Mm
Inch
Number of
measuring pipes
Inside pipe diameter 2 x mm
Pipe wall thickness
Mm
Mass flow
Kg/h
measuring range at
pressure drop of 2
bar at 1 g/cm
3
Density
Kg/dm
Fraction e.g. Brix
Brix
Temperature
Standard
Ex
Liquid pressure
PN
measuring pipe
Stainless steel (DIN
2413, 20〬C)
Materials, Wetted
Standard
parts
Hygienic
Enclosure
Enclosure material /
connection box
Process
connections
Electrical
connections
Cable length
m
Cable connection
Ex-version
ATEX 1443X
Weight approx
kg
Output
Table 9- 1
DN 20
SITRANS F C MC2
Operating Instructions, 10/2009, A5E02154544-02
20
25
¾
1
8.0
10.0
1
1
4600
7360
3
100
100
5 x 2 x o.35 mm
13
14
Display / frequency and pulse output MC2 sensors
5%
150 kg/h
40
50
65
2
2
16.0
22.0
29.0
1
1.5
1.5
21850
42600
87000
0.5-3.5
0-100
-50 to +180〬C
-20 to +180〬C
100
100
100
SS 1.4571 or Hastelloy C4
SS 1.4435 (316L)
IP67
1.4301 / aluminium
See Dimensions (Page 43)
Screw terminals, M20
Max. 300
twisted and screened in pairs, ext. Ø 12mm
2
II 2G EEx em [ib] IIC T6 (≤ DN 40 [1½"])
II 1/2 EEx em [ib] II C T6 (> DN 50 [2"])
18
34
47
50%
3000 kg/h
9
80
100
150
3
4
6
34.0
43.1
76.1
2.0
2.6
3.2
113400
192000
510000
100
40
40
58
91
260
100%
4600 kg/h
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans f c mc2 hygienic

Table of Contents