8504 OPERATOR'S MANUAL – SECTION 1

1 Introduction

Congratulations on your purchase of the 8504 
digital power amplifier. 8504 amplifiers are 350Vp, 
low-noise, DC-to-50-kHz switch -mode amplifiers. 
They are fast enough for DC automotive dropout 
testing and capable of AC voltages required for 
ISO 61000 and Aviation testing. Plus, they have 
low enough noise and distortion specifications to 
be the reference power source in power quality 
measurements.

1.1 Features

Wide Bandwidth and Flexible
The 8504 amplifier is capable of reproducing AC, 
DC and AC+DC waveforms into loads from a dead 
short to high impedance. It can be used to simu-
late a battery at 13.5 VDC or be an AC source with 
a L-N potential of up to 250 VAC. Rated current, 
for a given voltage, is available for all waveform 
types (AC, DC or AC+DC) at frequencies from DC 
to 50 kHz. Voltages from 0 to 250 VRMS are avail-
able with no changes in configuration.
Reuses Energy from Reactive Loads
The 8504 excels when it comes to driving reac-
tive loads. As frequencies increase, the effective-
impedance of the load becomes a much larger 
part of the total load to be driven (especially with 
inductive loads like coils).
However, when driving reactive loads, the 8504 is 
capable of receiving, reprocessing and returning 
to the load up to 5X its rated power. The result is a 
bench top system capable of 20 kVA+ output while 
drawing less than 4 kW of AC mains power!
96-8005353_02-17-2022
Figure 1.1 – 8504 Front Panel
Bandwidth
Voltage
Current
Distortion
Power
Apparent Power

1.2 Configuration Options

A key to everyday product usability is quick and 
easy product (re)configuration. The 8504 provides 
all key configuration controls on either the front 
or back panels of the unit. Configuration options 
available include:
Gain: Fixed or variable gain (0 to 40)
Current Limit: From 5% to rated limit (to 
protect fragile DUTs or where specified in the 
Standard)
DC Control: DC enabled or DC blocked and 
DC Servo (for driving transformer-coupled 
loads, coils)
Input: Balanced and/or unbalanced
Mode: Voltage source or current source
Output Impedance: Variable from 0 to 1 ohm 
(Voltage mode)
External Sense: Voltage drop compensation 
sense line
Information subject to change
Performance Overview
DC - 50 kHz
0 to 350 VDC
0 to 250 V
RMS
;
60 A
RMS
<0.2%
4 kW
20 kVA
5