8504 OPERATOR'S MANUAL – SECTION 6
6.4.1 Multiamp Safety Principles
Following these basic principles will help to ensure 
the safety of your equipment and personnel.
One Master Amplifier
Multi-amp configurations require one amplifier 
configured as a Master amplifier, and the second 
amplifier in the system configured as a Follower 
amplifier. 
Use Only 8504 Amplifiers
Use only AE Techron 8504 amplifers to construct 
a 8504 multiamp system. Do not combine different 
models of AE Techron amplifiers in the same sys-
tem or use amplifiers made by another manufac-
turer in a 8504 multiamp system. Such improper 
connections could damage the amplifiers. 
Use Proper Output Wiring
Select wire appropriate for your application, load 
and expected output. Parallel systems with a low-
impedance load running high-current, continuous-
duty applications may require 1/0 AWG or more. 
Please refer to an AWG wire sizes chart or the 
equivalent to determine the appropriate wire for 
your application.
Wire rating refers to the allowable voltage han-
dled by the wire. In configuring Push/Pull systems 
for increased voltage, make sure that the wire 
insulation on output wiring is appropriate for the 
expected output voltage. Wire length should also 
be limited to 20 feet to minimize voltage drop.
Never directly connect one amplifier's OUTPUT 
terminal to another amplifier's OUTPUT terminal, 
unless the Electronic Gain Matching option has 
96-8005353_02-17-2022
8504 Follower DIP Switch Settings
Parallel Configuration
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
8504 Master DIP Switch Settings
Parallel Configuration
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Figure 6.7 – Required DIP switch settings for parallel amplifiers
Information subject to change
been selected (see the Advanced Configuration
section of the product manual for more informa-
tion). The resulting circulating currents will waste 
power and may damage the amplifiers. 
6.4.2 Parallel Multi-amp Configuration
To configure and connect two amplifiers for opera-
tion in a parallel configuration, begin by designat-
ing one amplifier as the Master amplifier, and the 
other amplifier as a Follower amplifier. Consider 
placing a "Master" or "Follower" label on each am-
plifier's back panel to clarify the amplifier designa-
tion during setup and operation.
Testing Setup
The two amplifiers will be connected in a parallel 
configuration except for the OUTPUT terminals,
which will be left open.
Complete the following steps to configure and con-
nect the two amplifiers for gain testing.
1. Refer to Figure 6.7 to configure each am-
plifer's DIP switches for parallel operation. On 
the amplifier designated as Follower, set DIP
switch #7 in the DOWN (Follower) position.
On both amplifiers, set DIP switch #17 in the
UP (Electronic Gain Matching ON) position.
Note that other configuration settings con-
trolled by DIP switches can also be selected 
before operation. In an 8504 multi-amp system, 
all settings except for Control Configura-
tion (SW#7) and Electronic Gain Matching
(SW#17) are controlled by the Master ampli-
fier. For these additional configurations, setting 
of the DIP switches on the Follower amplifier is 
not required.
KEY FOR DIP SWITCH
SETTINGS:
REQUIRED
DEFAULT
OPTIONAL
NOT RECOMMENDED