AE Techron 8504 Operator's Manual page 23

Wide-bandwidth, high-power digital amplifier
Hide thumbs Also See for 8504:
Table of Contents

Advertisement

8504 OPERATOR'S MANUAL – SECTION 6
7. Check the accuracy between the oscilloscope 
channels by connecting channel two of the 
oscilloscope between the Master amplifier's 
Output connector and the GND bus bar. The 
measured output should be the same as the 
output recorded on channel one.
8. Move the channel two probes to connect be-
tween the Follower amplifier's Output connec-
tor and the GND bus bar. 
9. Observe the measured output on the two chan-
nels. Confirm that the signals are in phase and 
that the difference in measured output is less 
than 0.5V.
IMPORTANT: If the difference in output be-
tween the two amplifiers is greater than 0.5V,
DO NOT complete the system setup. Contact
AE Techron Technical Support for assistance.
Testing Using a Floating Digital Multimeter
1. Connect from a signal generator to the BNC 
or WECO signal input connector on the back 
panel of the Master amplifier. Note that if the 
WECO connector is used for signal input, DIP 
switch #1 on the Master amplifier should be 
placed in the DOWN (OFF) position and DIP 
switch #2 should be placed in the UP (ON) 
position. 
2. Turn down the level of your signal source.
3. Make sure the back panel breaker switch on 
both amplifiers is in the ON position, and then 
press the Standby-Run switch on each ampli-
fier's front panel to energizer the amplifiers. 
4. Wait for the green RUN LED to illuminate on 
the amplifier.
5. Connect the digital multimeter between the 
Master amplifier's Output connector and the 
GND bus bar. 
6. Adjust your signal source to input a 1 kHz,  2.5 
Vrms sinewave into the Master amplifier input. 
The measured output should be at or very near 
to 100 Vrms. Record the measured output.
7. Connect the digital multimeter between the 
Follower amplifier's Output connector and the 
GND bus bar. The measured output should be 
96-8005353_02-17-2022
at or very near to 100 Vrms. Record the mea-
sured output.
8. Set your multimeter to measure AC volts RMS 
at a low scale, then connect between the Mas-
ter Output connector and the Follower Output 
connector. The measured output should be 
less than 0.5V.
IMPORTANT: If the difference in output be-
tween the two outputs is greater than 0.5V, DO
NOT complete the system setup. Contact AE
Techron Technical Support for assistance.
Build Your Output Cables:
Build two cables for output wiring. 
1. Output Terminals: Use red, 8AWG cable 
to build a "Y" cable with legs of equal length 
(within 1/4-inch). IMPORTANT: The legs of
this output cable must be of equal length
for proper system operation. See Figure 6.9.
Terminate each of the two legs of the cable 
with 3/8-inch ring terminal ends to facilitate 
connection to the system's output connectors. 
Terminate the "Y" end into a spade lug, ring ter-
minal or other terminal suitable for the system 
output and adaptable to the connectors on the 
load. See Figure 6.10.
2. Ground Terminals: Use black, 4AWG cable to 
build a cable terminated at one end with a 3/8-
inch ring terminal to facilitate connector to the 
master amplifier's ground connector. Terminate 
the other end into a spade lug, ring terminal or 
other terminal suitabel for the system output 
and adaptaqble to the connectors on the load.
Figure 6.9 – Output cable for 8504 parallel systems