8504 OPERATOR'S MANUAL – SECTION 6
8504 PUSH/PULL SYSTEM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Generator
G.  Replace the output terminal covers on both 
amplifiers and secure.
6.4.4 Multiamp System Start-up
Procedure
1. Turn down the level of your signal source.
2. Make sure the back panel breaker switch on 
both amplifiers is in the ON position.
3. Press the Standby-Run switch on both the 
Master and the Follower amplifier to energize 
the amplifiers. Energizing the Master amplifier 
first is recommended, although not absolutely 
required. 
4. Wait for the green RUN LEDs to illuminate on 
both amplifiers.
96-8005353_02-17-2022
8504 AMP #2 - FOLLOWER
8504 AMP #1 - MASTER
and/or
Signal
Figure 6.13 – 8504 Push/Pull system setup
Information subject to change
AMPLIFIER
OUTPUTS
OUTPUT
GND
AMPLIFIER
OUTPUTS
OUTPUT
GND
KEY FOR DIP SWITCH
SETTINGS:
REQUIRED
SYSTEM REQUIREMENTS:
DEFAULT
(2) 8504 amplifiers
OPTIONAL
(1) 8504 Multi-amp Kit (69-8005462)
NOT RECOMMENDED
5. Adjust the input signal level to achieve the 
desired output level.
6.4.5 Multiamp System Operation
In multiamp systems, the Master amplifier controls 
several operating functions for both amplifiers in 
the system, so the Follower amplifier is said to be 
"interlocked" with the Master amplifier. The func-
tions controlled by the Master amplifer include 
input signal, operating status, mode of operation 
(controlled-voltage or controlled-current operation) 
and amplifier compensation. 
Because the amplifiers in a multiamp system are 
interlocked, the main and fault status indicators of
both amplifiers in the system must be considered 
8504
AMPLIFIERS
NOTE: No ground
should be used on
either side of the
load with this
configuration.