USE PROGRAM LOCK?
YES
NO
CHANGE PASSWORD?
YES
NO
ENTER NEW PASSWORD:
____
REENTER PASSWORD:
____

3.3.11 Language

SELECT OPTION: (<-->)
LANGUAGE
SELECT LANGUAGE (<-->)
ENGLISH

3.3.12 System IDs

SELECT OPTION: (<-->)
SYSTEM IDs
4700 SAMPLER
ID: ___________
HARDWARE: ___
SOFTWARE: _._

3.3.13 Run Diagnostics

3.3.14 Exit Configuration

2. Select YES to turn on the Program Lock feature or NO to
turn it off, then press Enter. If YES, the CHANGE PASS-
WORD option is displayed.
3. Select YES to change the password or NO to exit and leave
the password unchanged.
4. If YES was selected, enter a numeric password, up to four
characters, then press Enter.
5. Re-enter the password to confirm it. The sampler will alert
you if the passwords do not match and allow you to enter
them again.
Should you forget the password, contact Teledyne Isco's Cus-
tomer Service department for assistance.
Select this option to change the display language and display
units for length measurements.
1. Select the LANGUAGE option and press Enter.
2. Press the Next or Previous buttons to scroll through the
options. Press the Enter button when the desired option is
displayed. If you select a language other than English, the
sampler automatically displays length or distance units as
meters and returns to the SELECT OPTION <– –> screen.
If you select English, the sampler displays length or dis-
tance units as feet and returns to the SELECT OPTION <–
–> screen.
Select this option to view the system IDs. This function reports
the unique ID for the sampler, and its hardware and software
versions. These IDs are factory set.
1. Select the SYSTEM IDs option and press Enter.
2. The first line lists the Model Number. The second line lists
the unique ID for the sampler. Press Enter to continue.
3. This screen lists the version numbers of the installed hard-
ware and software. Press the Enter button to return to the
SELECT OPTION <– –> screen.
Select this option to enter the sampler diagnostics mode to test
the sampler memory, display, keypad, pump, distributor, and
various inputs and outputs.
For more information about this service-related feature, refer to
section 5.2.
Select this option to exit the configuration mode and return to
the Main Menu screen.