Unterminated Connect Cable - Teledyne 4700 Installation And Operation Manual

Refrigerated samplers
Hide thumbs Also See for 4700:
Table of Contents

Advertisement

b
Pin Wire Color
Signal Name
1
Black
12 VDC Power
2
White
Ground
3
Green
Flow Pulse
4
Blue
Serial Data
5
Orange
Event Mark
6
Red
Enable Pin
7
White/Black
12 VDC
8
Red/Black
Alarm 1
9
Red/White
Alarm 2
10
Orange/Black
Alarm 3
11
Green/Black
Alarm 4
12
Green/White
Analog 4-20 mA (+) Input
13
Blue/White
Analog 4-20 mA (–) Input
14
Blue/Black
Ground
15
Black/White
N/A
16
Bare
N/A
a. All voltage measurements are referenced to common ground on pins 2 and 14.
b. For color pairs, the first named color is the predominant color; the second named color is the spiral stripe around it.
c.
This pin is also used as the Serial Data Input for use with PC connections. Cable 69-4704-042 is recommended instead
for a serial data connection. See section 4.3.2.
d. Output from internal driver is current limited to 100 mA maximum. The output between the alarm pin and ground can drive
low-power alarm devices rated for 5 VDC. Control higher-power (>100 mA) devices, or devices with different voltage re-
quirements through a user-supplied relay. See section 3.3.8 to configure alarm conditions.
Table 2-3 Unterminated Connect Cable
Sampler
Input/Output
Output
N/A
Input
Output
Output
c
Input
Output
d
Output
d
Output
d
Output
d
Output
N/A
N/A
N/A
Isco 4700 Refrigerated Sampler
Section 2 Installation
a
Parameters/Comments
+12.5 VDC, 1 ampere maximum. Power for external
devices.
Common ground
25 millisecond (minimum) pulse, +5 to +15 VDC
For use with PC connections. Cable 69-4704-042 is
recommended. See section 4.3.2.
3 second, +12 VDC pulse at beginning of sample
collection
Ground this input (short to pin 2) to disable sampler
operation. Leave this input open (floating) to collect
samples.
+12.5 VDC, 1 ampere maximum. Power for external
devices.
Alarm Off = 0 VDC, Alarm On = +5 VDC
Alarm Off = 0 VDC, Alarm On = +5 VDC
Alarm Off = 0 VDC, Alarm On = +5 VDC
Alarm Off = 0 VDC, Alarm On = +5 VDC
Linear current loop signal representing minimum
flow rate at 4 mA, maximum flow rate at 20 mA.
This input is paired with pin 13.
See pin 12.
Common ground. Same as pin 2.
Not used
Not used
2-17

Advertisement

Table of Contents
loading

Table of Contents