Horizontal Termination
DuraVent manufactures a vent kit for horizontal that allows for terminating horizontally when installed in a
masonry fireplace (not for use with ZC fireplaces). The DuraVent kit (46DVA-HCL33 and 46DVA HCL34)
is approved for use with Travis Industries gas inserts.
These kits can be purchased from your Travis Industries dealer.
For inserts that use 3" exhaust and 3" intake
For inserts that use 4" exhaust and 3" intake
Refer to the kit manufacturer's instructions for details and requirements for installation. In addition to the
manufacturer's requirements, the following requirements must be met:
The termination center MUST be
a minimum of 5' from the base of
insert.
The termination center MUST
NOT be more than 8' from the
base of the insert.
The radius of any bends in the
flexible venting MUST NOT be
less than a 4" radius
All portions of the venting MUST
have at least a 1/4" rise per 12" of
horizontal run
© Travis Industries
Finalizing the Installation
Application
DuraVent Part #
46DVA-HCL33
46DVA-HCL34
r
4"
Radius
4" Min
5/20/2021 - 1558
Min. 5'
Max. 8'