Disclaimer Hand Held Products, Inc. d/b/a HHP (“HHP”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Hand Held Products to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of Hand Held Products.
Statement of Agency Compliance The IT2020/IT5620 system meets or exceeds the requirements of all applicable standards organizations for safe operation. However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency guidelines that follow. Please read these guidelines carefully before using your IT2020/IT5620 system.
Page 4
The user may find the following booklet helpful: “Something About Interference.” This is available at FCC local regional offices. Hand Held Products, Inc. is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Hand Held Products, Inc.
Page 5
Hand Held Products shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive. Regulatory Approvals for Bluetooth Radio Devices...
Page 6
UL and cUL Statement UL listed UL1950 and CSA 22.2 No.950. cUL listed UL1950 and CSA 22.2 No 950. TÜV Statement TÜV or GS marked to EN60950 and EN60825-1. C-Tick Statement Conforms to AS/NZS 3548. C-Tick number: N10410. Mexico Certified Patents Please refer to the IT5620 packaging for patent information.
Cordless System: Main Components... 1-3 About the Battery... 1-3 Proper Disposal of the Battery ... 1-4 Base Charge Mode... 1-5 Linking Scanner to Base... 1-6 Unlinking the Scanner... 1-6 Link Modes... 1-6 Locked Link Mode... 1-7 Open Link Mode ... 1-7 Out-of-Range Alarm...
Page 10
Connecting the Base with USB... 1-18 IBM SurePos ... 1-19 USB PC or Macintosh Keyboard... 1-19 USB HID ... 1-20 USB Com Port Emulation ... 1-20 Connecting the Base with Serial Wedge... 1-21 Chapter 2 - Terminal Interfaces Terminal ID... 2-1 Supported Terminals ...
Page 12
Chapter 5 - Data Formatting Data Format Editor Introduction... 5-1 To Add a Data Format ... 5-1 Other Programming Selections... 5-2 Data Format Editor Commands... 5-2 Data Format Editor ... 5-4 Data Formatter... 5-5 Alternate Data Formats... 5-5 Chapter 6 - Symbologies Introduction ...
Page 14
Keyboard Function Relationships ... 7-1 Supported Interface Keys... 7-3 Chapter 8 - Utilities To Add a Test Code I.D. Prefix to All Symbologies ... 8-1 Reset Scanner ... 8-1 Show Software Revision ... 8-1 Show Data Format... 8-1 Resetting the Standard Product Defaults... 8-2...
Page 15
IMAGETEAM 5620 Product Specifications ...11-1 IMAGETEAM 2020 Product Specifications ...11-2 IMAGETEAM 5620 Depth of Field ...11-3 Chapter 12 - Maintenance Maintenance ...12-1 Cleaning the Scanner’s Window...12-1 Inspecting Cords and Connectors ...12-1 Replacing the IT2020 Interface Cable: ...12-2 Troubleshooting Base...12-2 Chapter 13 - Customer Support Obtaining Factory Service...13-1...
Page 16
Appendix A Symbology Chart ... A-1 ASCII Conversion Chart (Code Page 1252) ... A-2 Code Page Mapping of Printed Bar Codes ... A-4 viii...
The IMAGETEAM 5620 cordless scanning system consists of one IT2020 base and one IT5620 Cordless Linear Imager. The IT5620 marks a new performance level for hand held scanners. The IT5620 is powered by Hand Held Products’ Adaptus Imaging Technology. The performance of Adaptus technology delivers aggressive read rates and depths of field on 1D codes.
Base: Keyboard wedge, TTL level 232, TTL level 232 serial wedge, IBM 4683, wand emulation, USB keyboard, USB HID, USB retail (IBM SurePOS) 2020-CB Base with charger only (no host interfaces) 5620SR0C0 Cordless Linear Scanner 1 - 2 IMAGETEAM™ 2020/5620 System Manual...
About the Battery Use only the Li-ion battery packs provided by Hand Held Products. The use of any battery pack not sold by Hand Held Products will void your warranty and may result in damage to your unit. Power is supplied to the cordless scanner by a rechargeable battery that is integrated in the scanner handle.
Replace it after the battery is unable to hold an adequate charge. • If you are not sure if the battery or charger is working properly, send it to Hand Held Products or an authorized Hand Held Products service center for inspection.
Using a slow charge rate draws less current (power) from the input power source when the battery is mostly discharged. Scan the appropriate bar code for your application. Default = Automatic . * Automatic Low Charge Rate IMAGETEAM™ 2020/5620 System Manual Condition 1 Condition 2 Fast Charge Slow Charge...
LED lights, the scanner has not linked to the base. Unlinking the Scanner If the base has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked. Once the previous scanner is unlinked, it will no longer communicate with the base.
"Unlinking the Scanner" on page 1-6.) If you need to replace a broken or lost scanner that is linked to a base, scan the Override Locked Scanner bar code below and place that scanner in the base. The locked link will be overridden; the broken or lost scanner’s link with the base will be removed, and the new scanner will be linked.
Out-of-Range Alarm Duration If your scanner is out range of the base, an alarm sounds from both your base and scanner. To activate the alarm options for the scanner or the base and to set the alarm duration, scan the appropriate bar code below and then set the time-out duration (from 0-3000 seconds) by scanning digits on the inside the back cover, then scanning Save.
Scan the bar codes below to turn data accumulation (batch) mode on and off. If data accumulation mode is on, bar code data is stored when the scanner is out of range of the base and transmitted once the scanner is back in range.
Basic Operation of the Cordless System Cordless Base The cordless base provides the link between the cordless scanner and the host system. The base contains an interface assembly and an RF communication module. The RF communication module performs the data exchange between the cordless scanner and the interface assembly.
Whenever the scanner can’t communicate with the base for a few seconds, it is out of range. If the scanner is out of range and you scan a bar code, the scanner issues a triple beep indicating no communication with the base.
The cordless scanner provides immediate feedback in the form of a “good read” indication (a green LED on the scanner and an audible beep) after a bar code is scanned correctly and the base has acknowledged receiving the data. This is possible since the cordless system provides two-way communication between the scanner and the base.
Page 29
The scanner’s battery is not charged when in this mode. Using the 9-volt, external power supply allows the scanner’s battery to be charged, and no power is drawn from the host.
Reading Techniques The scanner has a view finder that projects a bright red aiming beam that corresponds to its horizontal field of view. The aiming line should be centered horizontally over the bar code; it will not read if the aiming line is in any other direction.
Laptop Direct Connect For most laptops, scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the integral keyboard. The following Laptop Direct Connect bar code selects terminal ID 03, programs a carriage return (CR) suffix and turns on Emulate External Keyboard...
Idle State to high. (If you want to change the terminal ID only , without changing any other imager settings, please refer to Terminal ID on page 2-1.) Wand Emulation (Code 39 Format) Wand Emulation Same Code 1 - 16 IMAGETEAM™ 2020/5620 System Manual...
* Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-1, and IBM 4683 Port 17 Interfaces **Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface IMAGETEAM™ 2020/5620 System Manual IBM 4683 Port 5B Interface IBM 4683 Port 17 Interface...
The scanner’s battery is not charged when in this mode. Using the 9-volt, external power supply allows the scanner’s battery to be charged, and no power is drawn from the host.
IBM SurePos Scan one of the following “Plug and Play” codes to program the IT5620 for IBM SurePos (USB Hand Held scanner) or IBM SurePos (USB Tabletop scanner). Note: After scanning one of these codes, you must power cycle the cash register.
Scan the following code to program the IT5620 to emulate a regular RS-232- based Com Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Hand Held Products website (www.handheld.com The driver will use the next available Com Port number. Apple® Macintosh computers recognize the imager as a USB CDC class device and automatically uses a class driver.
6. Plug the power supply barrel connector to the base, and plug the power supply into the AC source. 7. Once the base has been fully connected, power up the computer. IMAGETEAM™ 2020/5620 System Manual on page 2-7 to set the baud rate 1 - 21...
Page 38
2-1. Make sure that all of the communication parameters match on all of the connected devices. Choosing Both sends scanned data to P1 and P2. Default = P1. * P1 Both P1 and P2 1 - 22 IMAGETEAM™ 2020/5620 System Manual...
Terminal ID bar code below, then scan the numeric bar code(s) from the Programming Chart inside the back cover of this manual to program the scanner for your terminal ID. Scan Save to save your selection. For example, an IBM AT terminal has a Terminal ID of 003. You would scan the...
Page 41
* Default for IT2020-5. **It is best to use the Plug and Play bar codes, beginning on interfaces, rather than scanning the terminal ID listed in this table. IMAGETEAM™ 2020/5620 System Manual Model(s) 078, 078A, 79, 80, 191, 196, 1191,1192, 1471, 1472, 1476,...
Please refer to Hand Held Products’ website (www.handheld.com) for complete keyboard country support information and applicable interfaces. If you need to program a keyboard for a country other than one listed above, scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) for the appropriate country from the inside back cover, then the Save bar code.
Relationships, page 7-1 for CTRL+ ASCII Values. Default = Off Control + ASCII Mode On * Control + ASCII Mode Off Turbo Mode: The scanner sends characters to a terminal faster. If the terminal drops characters, do not use Turbo Mode. Default = Off Turbo Mode On...
4. Plug the power supply barrel connector to the base, and plug the power supply into the AC source. 5. Once the base has been fully connected, power up the computer. IMAGETEAM™ 2020/5620 System Manual * Automatic Direct Connect Mode Off...
38,400 baud, parity–none, 8 data bits, 1 stop bit, and adds a suffix of a CR LF. RS-232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the same baud rate as the scanner.
These applications require that the host maintain control over the response indicators emitted from the source scanner. Turning the Host ACK selection on, configures the cordless system scanners to respond to commands from the host system.
• Scanner is suspended until 1) a valid escape string is received from the host system (via the base) or 2) the scanner “times out.” • Once condition 1 or 2 above has been met, the scanner is ready to scan again, and the process repeats.
Page 50
<ESC> 5 One beep at medium volume <ESC> 6 One beep at high volume <ESC> 7 Indicate as successful decode and communication to host. <ESC> 8 Indicate as unsuccessful decode and communication to host. 2 - 12 IMAGETEAM™ 2020/5620 System Manual...
Code 128. The Code 39 Format bar code below sets the terminal ID to 61, and the Same Code Format bar code sets the terminal ID to 64. Code 39 Format Same Code Format IMAGETEAM™ 2020/5620 System Manual 2 - 13...
Default = 25 inches/second. Wand Emulation Polarity The Polarity can be sent as standard with black bars high, or reversed with white bars high. Default = Black High. * Black High 2 - 14 IMAGETEAM™ 2020/5620 System Manual * 25 White High...
The idle describes the state of the scanner when no data is being transmitted. When in Wand Emulation mode, you must set the scanner’s idle state to match the idle state for the device to which the scanner is connected. Default = Idle High .
The check character is the character which when Exclusive-OR’d with every preceding character of the message yields a result of 0x00 (00H). Default = Off. Wand Emulation Overall Checksum On * Wand Emulation Overall Checksum Off 2 - 16 IMAGETEAM™ 2020/5620 System Manual...
Default = On. * Beeper - Good Read On Beeper - Good Read Off Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read. Default = Medium. * Medium High IMAGETEAM™...
Low (1600 Hz) * Medium (3250 Hz) High (4200 Hz) Beeper Duration – Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read. Default = Normal. * Normal Beep Short Beep LED –...
Default = One. Number of Pulses Good Read Delay This sets the minimum amount of time before the scanner can read another bar code. Default = 0 ms (No Delay. ) * No Delay...
"Trigger Commands" on page 10-4). When in manual trigger mode, the scanner scans until a bar code is read, or until the trigger is released. When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent.
Whenever the trigger is enabled, the “scanner power time-out timer” is reset. If the scanner is placed in the IT2020-5 cradle and the battery is in the process of being charged, the scanner will not go into power down mode.
Reread Delay This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads at POS (point of sale).
Use the centering feature to narrow the scanner’s field of view so the scanner reads only the bar code you want. When centering is turned on, the scanner only reads codes that intersect or are contained within the centering window you set up.
Output Sequence Overview Require Output Sequence When turned off, the bar code data will be output to the host as the scanner decodes it. When turned on, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device.
When it’s On/Not Required , the scanner will attempt to get the output data to conform to an edited sequence, but if it cannot, the scanner transmits all output data to the host device as is.
Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below. Note: Code 93 must be enabled to use this example.
Page 65
C - Code 93 sample length (11) plus CR suffix (1) = 12 start character match for Code 93, 43h = “C” termination string for third code IMAGETEAM™ 2020/5620 System Manual page 3-10, but assume a <CR> suffix and 3 - 11...
* Multiple Symbols Off No Read With No Read turned On , the scanner sends an “NR” to the host if you pull and release the trigger without reading a code (e.g., bad bar code). If No Read is turned Off , the “NR” will not be sent to the host.
• Enter prefixes and suffixes in the order in which you want them to appear on the output. • When setting up for specific symbologies (as opposed to all symbologies), the specific symbology ID value counts as an added prefix or suffix character. IMAGETEAM™ 2020/5620 System Manual Scanned Data Suffix variable length...
ASCII Conversion Chart (Code Page Programming Chart Programming Chart inside the back cover of this ASCII Conversion Chart (Code Page Programming Chart inside the back cover of this IMAGETEAM™ 2020/5620 System Manual (page 4-3). inside the back inside the back...
This action first clears all current suffixes, then programs a carriage return suffix for all symbologies. Prefix Selections Add Prefix Clear All Prefixes IMAGETEAM™ 2020/5620 System Manual Programming Chart Add CR Suffix All Symbologies inside the back...
Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys...
To remove this delay, scan the Delay Length bar code, and set the number of steps to 0. Scan the SAVE bar code using the back cover of this manual. IMAGETEAM™ 2020/5620 System Manual inside the back cover of this manual. Prefix...
Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output.
2-2), Code I.D. (refer to the inside the back cover of this manual inside the back cover of this manual ASCII Conversion Chart (Code Page 1252) IMAGETEAM™ 2020/5620 System Manual inside the back cover of Program- (page 5-2). Scan the sym-...
Page 75
(xx stands for the hex value for an ASCII code, see FC Disables suppress filter and clear all suppressed characters. Syntax = FC. IMAGETEAM™ 2020/5620 System Manual ASCII Conversion Chart (Code Page ASCII Conversion Chart (Code Page 1252) ASCII Conversion Chart (Code Page 1252) on page A-2.
Enter Data Format Clear One Data Format Save 5 - 4 ...zz where nn is the total count of both defines replacement characters, continuing IMAGETEAM™ 2020/5620 System Manual defines charac- on page A-2.) * Default Data Format Clear All Data Formats Discard...
1, 2, or 3. An alternate format is initiated by scanning one of the 3 alternate format bar codes below. The scanner will scan the next bar code, formatting the data with the selected alternate format, then revert immediately to the primary format.
Page 78
5 - 6 IMAGETEAM™ 2020/5620 System Manual...
• EAN/JAN All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology.
If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data.
No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate and Transmit , the scanner will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data.
Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted. Default = On.
Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit IMAGETEAM™ 2020/5620 System Manual 6 - 5...
Code 39 bar codes printed with a check character, but will not transmit the check character with the scanned data. When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data.
(excluding the start and stop symbols), and does not immediately transmit the data. The scanner stores the data in the order in which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space.
Character pairs /P through /Y decode as 0 through 9. Full ASCII On 6 - 8 SPACE 0 < %G L %H M > IMAGETEAM™ 2020/5620 System Manual ‘ %W p %M m %N n %O o DEL %T * Full ASCII Off...
< Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 * On Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. IMAGETEAM™ 2020/5620 System Manual 6 - 9...
Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data.
A-4, and scan the value and the SAVE bar code from the Programming Chart inside the back cover of this manual. The data characters should then appear properly. Code 93 Code Page IMAGETEAM™ 2020/5620 System Manual 6 - 11...
6-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length IATA Code 2 of 5 <Default All Code IATA 2 of 5 Settings> 6 - 12 IMAGETEAM™ 2020/5620 System Manual...
= 1-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Matrix 2 of 5 <Default All Matrix 2 of 5 Settings> Matrix 2 of 5 * Off IMAGETEAM™ 2020/5620 System Manual 6 - 13...
* Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits. One Check Digit * Two Check Digits 6 - 14 IMAGETEAM™ 2020/5620 System Manual...
6 - 16 Maximum Message Length on page A-4, and scan the value and the SAVE inside the back cover of this manual. The Code 128 Code Page IMAGETEAM™ 2020/5620 System Manual * Off Message Code Page...
* Off Telepen Output Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2).
* On UPC A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On 6 - 18 IMAGETEAM™ 2020/5620 System Manual...
2 Digit Addenda On 5 Digit Addenda On UPC A Addenda Required When Addenda Required is set to on, the scanner will only read UPC A bar codes that have addenda. Default = Not Required. Required IMAGETEAM™ 2020/5620 System Manual...
* On UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. Default = On. * On UPC E <Default All UPC E Settings> 6 - 20 IMAGETEAM™ 2020/5620 System Manual...
UPC E Expand expands the UPC E code to the 12 digit, UPC A format. Default = Off. * Off UPC E0 and UPC E1 Addenda Required When Addenda Required is set to on, the scanner will only read UPC E bar codes that have addenda. Default = Not Required. Required * Not Required IMAGETEAM™...
The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On 6 - 22 IMAGETEAM™ 2020/5620 System Manual...
This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On IMAGETEAM™ 2020/5620 System Manual * 2 Digit Addenda Off * 5 Digit Addenda Off...
2 Digit Addenda On 5 Digit Addenda On EAN/JAN 13 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 13 bar codes that have addenda. Default = Not Required. Required EAN/JAN 13 Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda.
* On EAN/JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On IMAGETEAM™ 2020/5620 System Manual 6 - 25...
2 Digit Addenda On 5 Digit Addenda On EAN/JAN 8 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 8 bar codes that have addenda. Default = Not Required. Required EAN/JAN 8 Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda.
MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate and Transmit , the scanner will only read MSI bar codes printed with the specified type check character, and will transmit this character at the end of the scanned data.
6-2 for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length 6 - 28 Maximum Message Length Maximum Message Length IMAGETEAM™ 2020/5620 System Manual Message * Off Message...
UCC/EAN-128 or RSS+Composite symbol. EAN•UCC data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, UCC/EAN-128, and EAN•UCC RSS and Composites. If UCC/EAN-128 Emulation is selected, the AIM Symbology 6 - 30 IMAGETEAM™ 2020/5620 System Manual...
Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/5620 System Manual 6 - 31...
Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length PosiCode <Default All PosiCode Settings> 6 - 32 IMAGETEAM™ 2020/5620 System Manual...
Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/5620 System Manual 6 - 33...
Scan the bar codes below to change the message length. Refer to Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048. Minimum Message Length 6 - 34 Maximum Message Length IMAGETEAM™ 2020/5620 System Manual * Off * Off Message...
Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81. Minimum Message Length Maximum Message Length 6 - 36 IMAGETEAM™ 2020/5620 System Manual...
Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-6 enable Control + ASCII mode. Function Code HEX/ASCII Value IMAGETEAM™...
Page 116
The following chart indicates the equivalents of these five characters for different countries. Country United States Belgium Scandinavia France Germany Italy Switzerland United Kingdom Denmark Norway Spain 7 - 2 Codes < < Ã < ¢ IMAGETEAM™ 2020/5620 System Manual...
Reserved Delete CR/Enter Insert Escape Home Print Back Space Back Tab * IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models) IMAGETEAM™ 2020/5620 System Manual IBM XTs and IBM, DDC, Memorex Compatibles Telex, Harris* Supported Keys Supported Keys Reserved Reserved CR/Enter...
Page 118
Enter New Line Tab/Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab IMAGETEAM™ 2020/5620 System Manual Memorex Telex (88)** Supported Keys Reserved Enter PF10 PF11 PF12 Reserved Reserved New Line Field Forward Field Forward...
Page 119
Supported Interface Keys ASCII IMAGETEAM™ 2020/5620 System Manual Esprit 200, 400 Esprit 200, 400 ANSI ASCII Supported Keys Supported Keys Reserved Reserved New Line New Line New Line New Line New Line New Line Escape Escape Insert Insert Back Space...
Page 120
Supported Interface Keys Apple Mac/iMac ASCII Supported Keys Reserved Enter/Numpad Enter CAPS ALT make ALT break CNTRL make CNTRL break RETURN APPLE make APPLE break RETURN Ins Help Home Prnt Scrn BACKSPACE LSHIFT TAB BACKSPACE 7 - 6 IMAGETEAM™ 2020/5620 System Manual...
For instructions on how to reset your scanner, refer to (page 8-1). Reset Scanner Scanning the following bar code clears temporary settings in the scanner and returns scanner to normal operation. Scanning this bar code also causes the scanner to re-link the radio.
Resetting the Standard Product Defaults If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want the standard product default settings restored, scan the Standard Product Default Settings bar code below. Menu Commands settings for each of the commands (indicated by an asterisk (*) on the programming pages).
Visual Menu 2003 Introduction Visual Menu 2003 provides the ability to configure a scanning device by connecting the scanner to the com port of a PC. Visual Menu 2003 allows you to download upgrades to a scanner’s firmware, change programmed parameters, and create and print programming bar codes.
Page 124
8. To start Visual Menu 2003, from the Start Menu click on Programs, Visual Menu 2003, Visual Menu 2003. Note: If you wish, you can create a shortcut to the Visual Menu 2003 executable on your desktop. 9 - 2 IMAGETEAM™ 2020/5620 User’s Guide...
(*) can be used :*:. Note: Since the base stores all work group settings and transfers to them to scanner once they are linked, changes are typically done to the base and not to the scanner. A 3 character case-insensitive field that identifies the desired menu command group.
Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields. 10 - 2 IMAGETEAM™ 2020/5620 System Manual...
(CBRENA) is 1, or on. Example #3: What is the device’s current setting for Codabar Coding Enable? Enter: cbrena?. Response: CBRENA1[ACK] This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on. IMAGETEAM™ 2020/5620 System Manual 10 - 3...
Activate:SYN T CR Deactivate:SYN U CR The scanner scans until a bar code has been read, until the deactivate com- mand is sent, or until the serial time-out has been reached (see (Serial Trigger Mode)
Link Modes Out-of-Range Alarm Alarm Sound Type Data Accumulation Mode Factory Default Settings Terminal Interfaces Terminal ID Program Keyboard Country IMAGETEAM™ 2020/5620 System Manual Setting * Indicates default *Automatic Full Charge Rate Low Charge Rate Battery Charge Off Unlink Scanner...
Page 130
Auto Direct Conn. On RS-232 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS *38400 BPS 57600 BPS 115200 BPS IMAGETEAM™ 2020/5620 System Manual Serial Command Page # Indicates a numeric entry KBDSTY0 KBDSTY1 KBDSTY2 KBDSTY6 KBDSTY5 KBDCAS0...
*Normal Beep Short Beep Range 1 - 9 *No Delay Short Delay (500 ms) Medium Delay (1000 ms) Long Delay (1500 ms) Range 0 - 30,000 ms IMAGETEAM™ 2020/5620 System Manual Serial Command Page # Indicates a numeric entry WNDDLY0 2-15...
Page 133
Output Sequence Editor Require Output Sequence Multiple Symbols No Read Video Reverse Prefix/Suffix Selections Add CR Suffix to All Symbologies IMAGETEAM™ 2020/5620 System Manual Setting * Indicates default *Manual Trigger Read Time-Out (0 - 300,000 ms) *0 Scanner Power Time-Out...
Clear One Data Format Clear All Data Formats *On, but Not Required On, Required All Symbologies Off All Symbologies On Default All Codabar Settings *Don’t Transmit Transmit IMAGETEAM™ 2020/5620 System Manual Serial Command Page # Indicates a numeric entry PREBK2## PRECL2 PRECA2 SUFBK2##...
Page 135
Code 32 Pharmaceutical (PARAF) Code 39 Full ASCII Interleaved 2 of 5 Interleaved 2 of 5 Interleaved 2 of 5 Check Digit IMAGETEAM™ 2020/5620 System Manual Setting * Indicates default *No Check Char. Validate, But Don’t Transmit Validate, and Transmit *Off...
Page 136
Maximum (1 - 80) *80 Default All Code 11 Settings *Off 1 Check Digit *2 Check Digits Minimum (1 - 80) *4 Maximum (1 - 80) *80 IMAGETEAM™ 2020/5620 System Manual Serial Command Page # Indicates a numeric entry I25MIN## 6-10...
Page 137
UPC A UPC A UPC A Check Digit UPC A Number System UPC A 2 Digit Addenda UPC A 5 Digit Addenda IMAGETEAM™ 2020/5620 System Manual Setting * Indicates default Default All Code 128 Settings *Off Minimum (0 - 80) *0...
Page 138
*Not Required Required Default All UPC E Settings *Off *Off *Off *Not Required Required Default All EAN/ JAN 13 Settings *Off *Off IMAGETEAM™ 2020/5620 System Manual Serial Command Page # Indicates a numeric entry UPAARQ0 6-19 UPAARQ1 6-19 UPAADS0 6-20 UPAADS1...
Page 140
Maximum (2 - 80) *80 Default All Korea Post Code Settings *Off Minimum (2 - 80) *4 Maximum (2 - 80) *48 Default All PosiCode Settings IMAGETEAM™ 2020/5620 System Manual Serial Command Page # Indicates a numeric entry PLSMIN## 6-28...
Page 141
Code 16K Code 16K Code 16K Code 49 Code 49 Code 49 IMAGETEAM™ 2020/5620 System Manual Setting * Indicates default A and B On A and B and Limited A On *A and B and Limited B On Minimum (2 - 80) *4...
Page 142
10 - 18 IMAGETEAM™ 2020/5620 System Manual...
-40° F to +140° F (-40° C to +60° C) Up to 95% non-condensing Operational after 50 drops from 3.3 feet (1 m) to concrete Withstands 5G peak from 22 to 300 Hz 15 kV to any external surface IP43 IMAGETEAM™ 2020/5620 System Manual 400mA 750mA 150mA...
7.5 mil Code 39 10 mil Code 39 13 mil Code 39 15 mil Code 39 20 mil Code 39 55 mil Code 39 IMAGETEAM™ 2020/5620 System Manual Maximum Near Field 1 in (2.5 cm) 4 in (10 cm) 2 in (5 cm) 1 in (2.5 cm)
Reading performance may degrade if the scanner’s window is not clean. If the window is visibly dirty, or if the scanner isn’t operating well, clean the window with a soft cloth or lens tissue dampened with water (or a mild detergent-water solution or alcohol).
• The host system power is on (if external power isn’t used). Is the green LED on? If the green LED isn’t illuminated, check that: • The scanner is correctly placed in the base. 12 - 2 IMAGETEAM™ 2020/5620 System Manual End Cap...
Page 153
Refer to information. Does the scanner read the bar code incorrectly? If the scanner reads a bar code, but the data is not displayed correctly on the host screen: • The base may not be programmed for the appropriate terminal interface.
Page 154
Resetting the Standard Product Defaults on page 10-4. Troubleshooting the Cordless System The scanner must be linked to the base for the system to work properly. "Linking Scanner to Base" on page 1-6. 12 - 4 IMAGETEAM™ 2020/5620 System Manual...
Hand Held Products provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, return the unit to Hand Held Products (postage paid) with a copy of the dated purchase record attached. Contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product.
(C) static electricity or electro-static discharge, (D) operation under conditions beyond the specified operating parameters, or (E) repair or service of the product by anyone other than Hand Held Products or its authorized representatives. This warranty shall extend from the time of shipment for the duration published by Hand Held Products for the product at the time of purchase ("Warranty...
Page 157
Held Products determines to its satisfaction that the product is defective due to defects in materials or workmanship, Hand Held Products, at its sole option, will either repair or replace the product without charge, except for return shipping to Hand Held Products.
Page 158
13 - 4 IMAGETEAM™ 2020/5620 System Manual...
Note: Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Refer to Data Editing beginning on page 4-1 and page 5-1 for information about using Code ID and AIM ID. IMAGETEAM™ 2020/5620 System Manual Symbology Korea Post Matrix 2 of 5 No Read ]K m...
ASCII Conversion Chart (Code Page 1252 Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings. Char A - 2 Char “ & ‘ < > IMAGETEAM™ 2020/5620 System Manual Char Char ‘...
Automatic National Replacement Characters Swedish Replacement Characters French/Belgium Replacement Charac- ters French/Belgium Replacement Charac- ters German Replacement Characters Italian Replacement Characters Swiss Replacement Characters British Replacement Characters Danish Replacement Characters Norwegian Replacement Characters Spanish Replacement Characters IMAGETEAM™ 2020/5620 System Manual...
Programming Chart Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save. Discard Save...
Page 168
HHP, Inc. 700 Visions Drive P.O. Box 208 Skaneateles Falls, NY 13153-0208 5620-SM Rev B 11/04...