Hand Held Products 2020 System Manual

Hand Held Products 2020 System Manual

Area imager cordless system
Hide thumbs Also See for 2020:
Table of Contents

Advertisement

IMAGETEAM™ 2020/4620
Area Imager Cordless System
System Manual

Advertisement

Table of Contents
loading

Summary of Contents for Hand Held Products 2020

  • Page 1 IMAGETEAM™ 2020/4620 Area Imager Cordless System ™ System Manual...
  • Page 2 Hand Held Products. Hand Held Products shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material.
  • Page 3: Statement Of Agency Compliance

    Statement of Agency Compliance The IT2020-5B/IT4620 system meets or exceeds the requirements of all applicable standards organizations for safe operation. However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency guidelines that follow. Please read these guidelines carefully before using your IT2020-5B/IT4620 system.
  • Page 4 The user may find the following booklet helpful: “Something About Interference.” This is available at FCC local regional offices. Hand Held Products, Inc. is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Hand Held Products, Inc.
  • Page 5 Nijverheidsweg 9 5627 BT Eindhoven The Netherlands Hand Held Products shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive.
  • Page 6 Bluetooth Qualified Product Bluetooth Qualified Body approved as a Bluetooth Class II radio. UL and cUL Statement UL listed UL1950 and CSA 22.2 No.950. cUL listed UL1950 and CSA 22.2 No 950. LED Safety Statement This device has been tested in accordance with EN60825-1 LED safety, and has been certified to be under the limits of a Class 1 LED device.
  • Page 7 Required Safety Labels IT4620 www.handheld.com...
  • Page 8 IT2020-5B...
  • Page 9: Table Of Contents

    Table of Contents Chapter 1 - Getting Started About This Manual ... 1-1 Unpacking the System ... 1-2 IT4620 Models... 1-2 Cordless System: Main Components... 1-2 About the Battery... 1-3 Proper Disposal of the Battery... 1-4 Connecting the Base When Powered by Host (Keyboard Wedge)...
  • Page 10 Programming the Interface - Terminal ID Method... 2-8 Supported Terminals... 2-9 Keyboard Country ... 2-11 Keyboard Style ... 2-13 Keyboard Modifiers... 2-14 RS-232 Baud Rate... 2-16 RS-232 Word Length: Data Bits, Stop Bits, and Parity2-17 RS-232 Receiver Time-Out... 2-18 RS-232 Handshaking ... 2-18 Host ACK Selection...
  • Page 11 Single Imager Operation ... 3-5 Locked Link Mode - Single Imager ... 3-5 Open Link Mode - Single Imager... 3-6 Override Locked Imager ... 3-6 Multiple Imager Operation ... 3-6 Imager Name... 3-7 Imager Report ... 3-8 Application Work Groups... 3-8 Application Work Group Selection...
  • Page 12 Presentation Mode ... 4-6 Presentation LED Behavior after Decode ... 4-7 Presentation Sensitivity... 4-7 Hands Free Time-Out ... 4-7 Reread Delay ... 4-8 User-Specified Reread Delay ... 4-8 LED Power Level ... 4-9 Illumination Lights ... 4-9 Aimer Delay... 4-10 User-Specified Aimer Delay ...
  • Page 13 Data Format Editor Introduction... 6-1 To Add a Data Format... 6-1 Other Programming Selections ... 6-2 Data Format Editor Commands... 6-2 Data Format Editor... 6-5 Data Formatter... 6-5 Alternate Data Formats ... 6-6 Chapter 7 - Symbologies All Symbologies ... 7-2 Message Length Description...
  • Page 14 Code 11 ... 7-16 Check Digits Required ... 7-16 Code 11 Message Length ... 7-16 Code 128 ... 7-17 ISBT 128 Concatenation ... 7-17 Code 128 Message Length ... 7-18 Code 128 Code Page ... 7-18 Telepen ... 7-18 Telepen Output... 7-19 Telepen Message Length...
  • Page 15 EAN/JAN-8 ... 7-27 EAN/JAN-8 Check Digit... 7-27 EAN/JAN-8 Addenda... 7-28 EAN/JAN-8 Addenda Required... 7-28 EAN/JAN-8 Addenda Separator ... 7-28 MSI ... 7-29 MSI Check Character ... 7-29 MSI Message Length... 7-30 Plessey Code ... 7-30 Plessey Message Length... 7-30 RSS-14 ... 7-31 RSS Limited ...
  • Page 16 EAN•UCC Emulation ... 7-40 TCIF Linked Code 39 (TLC39) ... 7-40 Postal Codes ... 7-41 Postnet ... 7-41 Planet Code ... 7-42 British Post ... 7-42 Canadian Post... 7-42 Kix (Netherlands) Post... 7-43 Australian Post ... 7-43 Japanese Post... 7-43 China Post ...
  • Page 17 U.S. Currency Font ... 9-3 MICR E13 B Font ... 9-3 SEMI Font ... 9-4 OCR Templates... 9-4 Creating an OCR Template ... 9-5 Stringing Together Multiple Formats (Creating “Or” Statements) ... 9-7 OCR User-Defined Variables ... 9-7 Reading Multi-Row OCR... 9-8 OCR Check Character...
  • Page 18 Imaging Default Commands ... 12-22 Image Snap ... 12-22 Image Snap (continued) ... 12-23 OCR Selections ... 12-25 Chapter 13 - Product Specifications IT4620 Product Specifications ... 13-1 IMAGETEAM 2020-5B Product Specifications... 13-2 Chapter 14 - Maintenance Repairs ... 14-1...
  • Page 19 Maintenance... 14-1 Cleaning the Imager’s Window... 14-1 Inspecting Cords and Connectors... 14-1 Replacing the IT2020-5B Interface Cable: ... 14-2 Troubleshooting Base ... 14-2 Chapter 15 - Customer Support Product Service and Repair... 15-1 Technical Assistance... 15-2 Limited Warranty ... 15-3 Appendix A Symbology Chart ...
  • Page 21: Chapter 1 - Getting Started

    IT4620 Cordless Area Imager. Up to seven imagers may be linked to one base. The IT4620 marks a new performance level for hand held area imagers. The IT4620 hand held area imager is powered by Hand Held Products Adaptus Imaging Technology.
  • Page 22: Unpacking The System

    IBM 4683, wand emulation, USB keyboard, USB HID, USB retail (IBM SurePOS) 4620SR0C1B Cordless Area Imager - Green aimer 4620SF0C1B Cordless Area Imager - Green aimer Cordless System: Main Components 1 - 2 Battery Contained in Handle IMAGETEAM™ 2020/4620 System Manual...
  • Page 23: About The Battery

    About the Battery Use only the Li-ion battery packs provided by Hand Held Products. The use of any battery pack not sold by Hand Held Products will void your warranty and may result in damage to your unit. Power is supplied to the cordless imager by a rechargeable battery that is integrated in the imager handle.
  • Page 24: Proper Disposal Of The Battery

    Do not incinerate the battery or dispose of the battery with general waste materials. You may send batteries to Hand Held Products (postage paid). The shipper is responsible for complying with all federal, state, and local laws and regulations related to the packing, labeling, manifesting, and shipping of spent batteries.
  • Page 25: Connecting The Base With Usb

    3. Verify the base operation by scanning a bar code from the in the back of this manual. For additional USB programming and technical information, refer to the Hand Held Products “USB Application Note,” available at IMAGETEAM™ 2020/4620 System Manual "Keyboard Wedge Sample Symbols Sample Symbols www.handheld.com...
  • Page 26: Connecting The Base With Rs-232 Serial Port

    5. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 6. Once the imager has been fully connected, power up the computer. 1 - 6 IMAGETEAM™ 2020/4620 System Manual...
  • Page 27: Connecting The Base With Serial Wedge

    6. Plug the power supply barrel connector to the base, and plug the power supply into the AC source. 7. Once the base has been fully connected, power up the computer. IMAGETEAM™ 2020/4620 System Manual on page 2-16 to set the baud rate and communications 1 - 7...
  • Page 28: Linking Imager To Base

    LED lights, the imager has successfully linked to the base. If you receive a triple error beep and the red LED lights, the imager has not linked to the base. 1 - 8 IT4620 Imager IT2020-5B Cordless Base IMAGETEAM™ 2020/4620 System Manual...
  • Page 29: Communication Between The Cordless System And The Host

    (ACK) from the base unit. If it cannot be determined that the data has been properly sent to the base, the imager issues an error indication. You must then check to see if the scanned data was received by the host system. IMAGETEAM™ 2020/4620 System Manual 3) Base sends data to host...
  • Page 30: Reading Techniques

    If the code being scanned is highly reflective (e.g., laminated), it may be necessary to tilt the code up 15° to 18° to prevent unwanted reflection. 1 - 10 IMAGETEAM™ 2020/4620 System Manual...
  • Page 31: Chapter 2 - Programming The Interface

    The following Laptop Direct Connect bar code selects terminal ID 03, programs a carriage return (CR) suffix and turns on Emulate External Keyboard IMAGETEAM™ 2020/4620 System Manual IBM PC AT and Compatibles with CR suffix...
  • Page 32: Rs-232

    Idle State to high. (If you want to change the terminal ID only , without changing any other imager settings, please refer to Wand Emulation Plug & Play (Code 39 Format) 2 - 2 RS-232 Interface Introduction IMAGETEAM™ 2020/4620 System Manual on page 2-1.) Wand Emulation Plug & Play Same Code...
  • Page 33: Ibm 4683 Ports 5B, 9B, And 17 Interface

    * Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-1, and IBM 4683 Port 17 Interfaces **Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface IMAGETEAM™ 2020/4620 System Manual Symbology EAN 8...
  • Page 34: Ibm Surepos

    Symbology EAN 8 EAN 13 UPC A UPC E Code 39 Interleaved 2 of 5 Code 128 IMAGETEAM™ 2020/4620 System Manual IBM SurePos (USB Tabletop Imager) Interface Suffix 00 0A 0B 00 0D 0B 00 18 0B USB Keyboard (Mac)
  • Page 35: Usb Hid

    Scan the following code to program the IT4620 to emulate a regular RS-232- based Com Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Hand Held Products website (www.handheld.com). The driver will use the next available Com Port number. Apple® Macintosh computers recognize the imager as a USB CDC class device and automatically uses a class driver.
  • Page 36: Serial Wedge

    2-1. Make sure that all of the communication parameters match on all of the connected devices. Choosing Both sends scanned data to P1 and P2. Default = P1. * P1 Both P1 and P2 2 - 6 IMAGETEAM™ 2020/4620 System Manual...
  • Page 37: Resetting The Standard Product Default Settings: Current Application Work Group

    The following bar code defaults all of the work groups to the factory settings. Standard Product Default Settings: Menu Commands settings for each of the commands (indicated by an asterisk (*) on the programming pages). IMAGETEAM™ 2020/4620 System Manual starting on page 12-6 Standard Product Default Settings: Current Application Group...
  • Page 38: Programming The Interface - Terminal Id Method

    Terminal ID bar code, scan the digits, and the Save code again. Note: The default interface is Keyboard Wedge (Term ID = 003). Terminal ID Save Note: After scanning one of these codes, you must power cycle your computer. 2 - 8 IMAGETEAM™ 2020/4620 System Manual...
  • Page 39: Supported Terminals

    IBM Thinkpad I/O 122 key Lee Data Olivetti Olivetti RS-232 TTL Serial Wedge Silicon Graphics IMAGETEAM™ 2020/4620 System Manual Model(s) 3496, 3497, 122 key 3496, 3497, 102 key VT510, 520, 525 (PC style) VT510, 520, 525 (DEC style LK411) 200, 400...
  • Page 40 Data Entry Keyboard 078, 078A, 79, 80, 191, 196, 1191,1192, 1471, 1472, 1476, 1477, 1483 078, 078A, 79, 80, 191, 196, 1191,1192, 1471, 1472, 1476, 1477, 1482, 1483 IMAGETEAM™ 2020/4620 System Manual Terminal 124** 125** 131** page 2-1 to program these...
  • Page 41: Keyboard Country

    United States: @ | $ # { } [ ] = / ‘ \ < > ~ * United States Belgium Brazil Canada (French) Czechoslovakia Denmark Finland (Sweden) France Germany/Austria Greece Hungary Israel (Hebrew) IMAGETEAM™ 2020/4620 System Manual 2 - 11...
  • Page 42 Keyboard Country (continued) Italy Netherlands (Dutch) Poland Romania Spain Switzerland (German) 2 - 12 IMAGETEAM™ 2020/4620 System Manual Latin America Norway Portugal Russia Slovakia Sweden...
  • Page 43: Keyboard Style

    Caps Lock on or off (AT and PS/2 only). This selection can only be used with systems that have an LED which notes the Caps Lock status. Automatic Caps Lock IMAGETEAM™ 2020/4620 System Manual 2 - 13...
  • Page 44: Keyboard Function Relationships

    * Control + ASCII Mode Off Turbo Mode: The imager sends characters to a terminal faster. If the terminal drops characters, do not use Turbo Mode. Default = Off Turbo Mode On * Turbo Mode Off 2 - 14 IMAGETEAM™ 2020/4620 System Manual...
  • Page 45 Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off Automatic Direct Connect Mode On * Automatic Direct Connect Mode Off IMAGETEAM™ 2020/4620 System Manual 2 - 15...
  • Page 46: Rs-232 Baud Rate

    Baud Rate sends the data from the imager to the terminal at the specified rate. The host terminal must be set for the same baud rate as the imager. Default = 115,200. 1200 4800 19200 57,600 2 - 16 IMAGETEAM™ 2020/4620 System Manual 2400 9600 38400 * 115,200...
  • Page 47: Word Length: Data Bits, Stop Bits, And Parity2-17

    7 Data, 2 Stop Parity None 8 Data, 1 Stop, Parity Even 8 Data, 1 Stop, Parity Odd IMAGETEAM™ 2020/4620 System Manual 7 Data, 1 Stop, Parity None 7 Data, 2 Stop, Parity Even 7 Data, 2 Stop, Parity Odd...
  • Page 48: Rs-232 Receiver Time-Out

    XON character (DC1, hex 11). Data transmission continues where it left off when XOFF was sent. Default = RTS/CTS, XON/XOFF and ACK/NAK Off . RTS/CTS On * RTS/CTS Off XON/XOFF On * XON/OFF Off ACK/NAK On * ACK/NAK Off 2 - 18 IMAGETEAM™ 2020/4620 System Manual...
  • Page 49: Host Ack Selection

    10 seconds. If a time out occurs, the operator should check the host system to understand why a response to the imager was not received. IMAGETEAM™ 2020/4620 System Manual (page 2-20).
  • Page 50: Host Ack Enable

    Host ACK Enable Host ACK On * Host ACK Off 2 - 20 IMAGETEAM™ 2020/4620 System Manual...
  • Page 51: Wand Emulation

    The Same Code Format transmits UPC, EAN, Code 128 and Interleaved 2 of 5 without any changes, but converts all other symbologies to Code 39. 2D symbologies are converted to Code 128. IMAGETEAM™ 2020/4620 System Manual on page 2-2 for further information. 2 - 21...
  • Page 52: Wand Emulation Data Block Size

    Code Format bar code sets the terminal ID to 64. Default = Code 39 Format. Code 39 Format Same Code Format Wand Emulation Data Block Size This transmits the data in smaller blocks to prevent buffer overflow. Default = 40. * 40 2 - 22 IMAGETEAM™ 2020/4620 System Manual...
  • Page 53: Wand Emulation Delay Between Blocks

    The check character is the character which when Exclusive-OR’d with every preceding character of the message yields a result of 0x00 (00H). Default = Off. Wand Emulation Overall Checksum On * Wand Emulation Overall Checksum Off IMAGETEAM™ 2020/4620 System Manual 2 - 23...
  • Page 54: Wand Emulation Transmission Rate

    Default = 25 inches/second. Wand Emulation Polarity The Polarity can be sent as standard with black bars high, or reversed with white bars high. Default = Black High. * Black High 2 - 24 IMAGETEAM™ 2020/4620 System Manual * 25 White High...
  • Page 55: Wand Emulation Idle

    When in Wand Emulation mode, you must set the imager’s idle state to match the idle state for the device to which the imager is connected. Default = Idle High . * Idle High Idle Low IMAGETEAM™ 2020/4620 System Manual 2 - 25...
  • Page 56 2 - 26 IMAGETEAM™ 2020/4620 System Manual...
  • Page 57: Chapter 3 - Basic System Operation

    (parameter menuing, visual indicator support, low battery indication), and data translation required for the host system. The RF communication module performs the data exchange between the imager and the base. IMAGETEAM™ 2020/4620 System Manual 3 - 1...
  • Page 58: System Conditions

    Once the radio connection is made, the imager produces a series of beeps while the data is being transferred to the base. 3 - 2 IMAGETEAM™ 2020/4620 System Manual...
  • Page 59: Base Charge Mode

    Imager inserted into base >80% charged 30% to 80% charged <30% charged Note: Charging only occurs with external power applied to the IT2020-5B or 12 volt Host power. IMAGETEAM™ 2020/4620 System Manual Condition 1 Condition 2 Fast Charge Slow Charge Fast Charge...
  • Page 60: Beeper And Led Sequences And Meaning

    Blink LED for long duration, pulsing indefinitely Blink LED for short duration in multiple pulses. Occurs while transferring data to/from the RF module or the Host port. Blink LED once (occurs approx. every 30 seconds) IMAGETEAM™ 2020/4620 System Manual Cause Battery low Successful communication or linking...
  • Page 61: Imager Modes

    * Locked Link Mode (Single Imager) To use a different imager, you need to unlink the original imager by scanning the Unlink Imager bar code. (See "Imager Modes" on page 3-5.) IMAGETEAM™ 2020/4620 System Manual 3 - 5...
  • Page 62: Open Link Mode - Single Imager

    You cannot join an eighth imager until you unlink one of the 7 imagers or take an imager out of range. 3 - 6 Open Link Mode (Single Imager) Override Locked Imager (Single Imager) Multiple Imager Operation IMAGETEAM™ 2020/4620 System Manual...
  • Page 63: Imager Name

    If you wanted set up your imagers with names 0001-0007, you may scan the bar codes below. Scan the Reset bar code after each name change and wait for the scanner to re-link to the base before scanning the next bar code to name the next imager.
  • Page 64: Imager Report

    Programming Chart scan Save. Then scan the Reset bar code and wait for the scanner to re-link to the base before scanning the next bar code. Repeat that process for imager number 2 , 3, 4 etc.
  • Page 65: Application Work Group Selection

    You may then program the settings (e.g., beeper volume, prefix/suffix, data formatter) that your application requires. * Group 0 Group 2 Group 4 Group 6 IMAGETEAM™ 2020/4620 System Manual Group 1 Group 3 Group 5 3 - 9...
  • Page 66: Resetting The Standard Product Default Settings: All Application Work Groups

    3 - 10 All Application Groups starting on page 12-6 starting on page 12-6 list the factory default settings for Standard Product Default Settings: Current Application Group IMAGETEAM™ 2020/4620 System Manual list the standard product default "Imager Modes"...
  • Page 67: Using The Imager With Bluetooth Devices

    To change the PIN, scan the bar code below and then scan the appropriate numeric bar codes from the Programming Chart inside the back cover of this manual. Scan Save to save your selection. Bluetooth PIN IMAGETEAM™ 2020/4620 System Manual 3 - 11...
  • Page 68: Out-Of-Range Alarm

    (0-7) bar code and the Save bar code on the inside the back cover of this manual. Default = 0. Set the sound type to fit your application. Base Alarm Type 3 - 12 Imager Alarm Duration Imager Alarm Type IMAGETEAM™ 2020/4620 System Manual Programming Chart Programming Chart...
  • Page 69: Data Accumulation Mode

    Data Accumulation Mode On * Data Accumulation Mode Off IMAGETEAM™ 2020/4620 System Manual 3 - 13...
  • Page 70 3 - 14 IMAGETEAM™ 2020/4620 System Manual...
  • Page 71: Chapter 4 - Output

    Beeper - Good Read Off Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the imager emits on a good read. Default = Medium. * Medium High IMAGETEAM™ 2020/4620 System Manual 4 - 1...
  • Page 72: Beeper Pitch - Good Read

    LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On. * LED - Good Read On LED - Good Read Off 4 - 2 IMAGETEAM™ 2020/4620 System Manual...
  • Page 73: Number Of Beeps - Good Read

    If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save . User-Specified Good Read Delay IMAGETEAM™ 2020/4620 System Manual 4 - 3...
  • Page 74: Serial Trigger Modes

    After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by scanning digits on the Programming Chart inside the back cover, then scanning Save. Default = 300,000 ms. Read Time-Out 4 - 4 IMAGETEAM™ 2020/4620 System Manual...
  • Page 75 There will be a set of power up beeps and a delay of up to a few seconds for the radio to join. The imager will then be ready to use. IMAGETEAM™ 2020/4620 System Manual 200 seconds 900 seconds...
  • Page 76: Scan Stand Mode

    LEDs on at the configured power level (Default High) and attempts to find and decode bar codes in its field of view. Scan Stand Symbol Presentation Mode This programs the imager to work in Presentation Mode. Presentation Mode 4 - 6 IMAGETEAM™ 2020/4620 System Manual...
  • Page 77: Presentation Led Behavior After Decode

    Scan the Hands Free Time-Out bar code, then scan the time-out duration (from 0-300,000 milliseconds) from the inside back cover, and Save . Default = 5,000 Hands Free Time-Out IMAGETEAM™ 2020/4620 System Manual 4 - 7...
  • Page 78: Reread Delay

    (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save . 4 - 8 Presentation Mode User-Specified Reread Delay IMAGETEAM™ 2020/4620 System Manual (see page 4-6). * Medium (750 ms) Extra Long (2000 ms) Extra Long (2000 ms)
  • Page 79: Led Power Level

    Lights Off bar code. Note: This setting does not affect the aimer light. The aiming light can be set using Aimer Mode * Lights On IMAGETEAM™ 2020/4620 System Manual Aimer Delay (page 4-11). on page 4-10), the Low (50%) Lights Off...
  • Page 80: Aimer Delay

    If you want to set your own length for the duration of the delay, scan the bar code below, then set the time-out by scanning digits (0 - 4,000 ms) from the Programming Chart inside the back cover of this manual, then scan Save. Delay Duration 4 - 10 IMAGETEAM™ 2020/4620 System Manual...
  • Page 81: Aimer Mode

    In the example below, the gray area is the full imager field of view and the white area is the centering window. Bar Code 1 will not be read, while Bar Code 2 will Bar Code 1 Bar Code 2 IMAGETEAM™ 2020/4620 System Manual * Concurrent Aimer Delay, page 4-10, for...
  • Page 82 Scan Save . Default Centering = 40% for Top and Left, 60% for Bottom and Right. Centering On Top of Centering Window Left of Centering Window 4 - 12 Bottom Default Center IMAGETEAM™ 2020/4620 System Manual 100% * Centering Off Bottom of Centering Window Right of Centering Window...
  • Page 83: Decode Search Mode

    This mode is not omnidirectional, but does quickly read linear and stacked bar codes. Advanced Linear Decoding cannot read 2D, OCR, or Postal symbols. Note: This search mode is the default setting for the IT4620 point-and-shoot PDF imager. Advanced Linear Decoding IMAGETEAM™ 2020/4620 System Manual 4 - 13...
  • Page 84: Output Sequence Overview

    Other Programming Selections • Discard This exits without saving any Output Sequence changes. 4 - 14 Multiple on page A-1, find the symbology to which you want Codes, page A-6, find the Hex IMAGETEAM™ 2020/4620 System Manual Symbols, page 4-17).
  • Page 85: Output Sequence Example

    9999 code length that must match for Code 93, 9999 = all lengths start character match for Code 93, 43h = “C” termination string for third code IMAGETEAM™ 2020/4620 System Manual A - Code 39 B - Code 128 C - Code 93...
  • Page 86: Output Sequence Editor

    When it’s On/Not Required , the imager will attempt to get the output data to conform to an edited sequence, but if it cannot, the imager transmits all output data to the host device as is. 4 - 16 page 4-15, but assume a <CR> suffix and IMAGETEAM™ 2020/4620 System Manual Default Sequence...
  • Page 87: Multiple Symbols

    With No Read turned On , the imager notifies you if a code cannot be read. If using a Quick*View Scan Data Window, an “NR” appears when a code cannot be read. If No Read is turned Off , the “NR” will not appear. * Off IMAGETEAM™ 2020/4620 System Manual 4 - 17...
  • Page 88: Print Weight

    Video Reverse must be disabled to read the menu bar codes and then re-enabled after menuing is completed. Note: Images downloaded from the unit will not be reversed. This is a setting for decoding only. * Off 4 - 18 IMAGETEAM™ 2020/4620 System Manual...
  • Page 89: Working Orientation

    Default = Upright. Upright: Rotate Clockwise 90°: Upside Down: Rotate Counterclockwise 90°: * Upright Rotate Clockwise 90° Upside Down Rotate Counterclockwise 90° IMAGETEAM™ 2020/4620 System Manual 4 - 19...
  • Page 90 4 - 20 IMAGETEAM™ 2020/4620 System Manual...
  • Page 91: Chapter 5 - Data Editing

    • Enter prefixes and suffixes in the order in which you want them to appear on the output. • When setting up for specific symbologies (as opposed to all symbologies), the specific symbology ID value counts as an added prefix or suffix character. IMAGETEAM™ 2020/4620 System Manual Scanned Data Suffix variable length 1-11 alpha numeric &...
  • Page 92: To Add A Prefix Or Suffix

    Code Page Mapping of Printed Bar Programming Chart Programming Chart inside the back cover of this Code Page Mapping of Printed Bar Programming Chart inside the back cover of this IMAGETEAM™ 2020/4620 System Manual (page 5-4). inside the back inside the back...
  • Page 93: To Clear One Or All Prefixes Or Suffixes

    Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies. IMAGETEAM™ 2020/4620 System Manual Programming Chart Add CR Suffix...
  • Page 94: Supported Interface Keys

    10-3. When the imager is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable. * Enable 5 - 4 Supported Interface Keys IMAGETEAM™ 2020/4620 System Manual Clear One Prefix Clear One Suffix starting on Disable...
  • Page 95: Intercharacter, Interfunction, And Intermessage Delays

    To remove this delay, scan the Intercharacter Delay bar code, then set the number of steps to 0. Scan the SAVE bar code using the Programming Chart inside the back cover of this manual. Note: Intercharacter delays are not supported in USB serial emulation. IMAGETEAM™ 2020/4620 System Manual 5 - 5...
  • Page 96: User Specified Intercharacter Delay

    To remove this delay, scan the Interfunction Delay bar code, then set the number of steps to 0. Scan the SAVE bar code using the Programming Chart inside the back cover of this manual. 5 - 6 IMAGETEAM™ 2020/4620 System Manual...
  • Page 97: Intermessage Delay

    To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 0. Scan the SAVE bar code using the Programming Chart inside the back cover of this manual. IMAGETEAM™ 2020/4620 System Manual 5 - 7...
  • Page 98 5 - 8 IMAGETEAM™ 2020/4620 System Manual...
  • Page 99: Chapter 6 - Data Formatting

    ID (you must enter 3 dig- its). For example, scan 0 0 3 for an AT wedge. IMAGETEAM™ 2020/4620 System Manual (page inside the back cover of this manual. If you are pro-...
  • Page 100: Other Programming Selections

    2-9), and the bar code data length for inside the back cover of this manual inside the back cover of this manual Code Page Mapping of Printed Bar Codes IMAGETEAM™ 2020/4620 System Manual inside the back cover of this Program- (page 6-2). Scan the symbols...
  • Page 101 (xx stands for the hex value for an ASCII code, see FC Disables suppress filter and clear all suppressed characters. Syntax = FC. IMAGETEAM™ 2020/4620 System Manual Code Page Mapping of Printed Bar Code Page Mapping of Printed Bar Codes Code Page Mapping of Printed Bar Codes on page A-6.
  • Page 102 ED Check to make sure there is a non-numeric ASCII character at the current cursor position. If character is numeric, format is aborted. Syntax = ED . 6 - 4 ...zz where nn is the total count of both defines replacement characters, continuing IMAGETEAM™ 2020/4620 System Manual defines charac- on page A-6.)
  • Page 103: Data Format Editor

    Data Formatter Off When Data Formatter is required, all input data must conform to an edited format or the imager does not transmit the input data to the host device. Data Format On, Format Required IMAGETEAM™ 2020/4620 System Manual 6 - 5...
  • Page 104: Alternate Data Formats

    The imager will scan the next bar code, formatting the data with the selected alternate format, then revert immediately to the primary format. Alternate Data Format 1 Alternate Data Format 2 Alternate Data Format 3 6 - 6 IMAGETEAM™ 2020/4620 System Manual...
  • Page 105 Code 93 • Data Matrix • EAN/JAN-13 • EAN/JAN-8 • EAN•UCC Composite Codes • IATA Code 2 of 5 IMAGETEAM™ 2020/4620 System Manual • Interleaved 2 of 5 • Japanese Post • Kix (Netherlands) Post • Korea Post • Matrix 2 of 5 •...
  • Page 106: All Symbologies

    The minimum and maximum lengths and the defaults are included with the respective symbologies. 7 - 2 All Symbologies Off Max. length = 20 Max. length = 15 IMAGETEAM™ 2020/4620 System Manual Programming Chart...
  • Page 107: Codabar

    Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit . Transmit * Don’t Transmit IMAGETEAM™ 2020/4620 System Manual 7 - 3...
  • Page 108: Codabar Check Character

    Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit 7 - 4 IMAGETEAM™ 2020/4620 System Manual...
  • Page 109: Codabar Concatenation

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual 7 - 5...
  • Page 110: Code 39

    Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit 7 - 6 IMAGETEAM™ 2020/4620 System Manual...
  • Page 111: Code 39 Check Character

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-48. Minimum Default = 0, Maximum Default = 48. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual 7 - 7...
  • Page 112: Code 39 Append

    Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as PARAF. Note: Trioptic Code (page Pharmaceutical codes. 7 - 8 7-34) must be turned off while scanning Code 32 IMAGETEAM™ 2020/4620 System Manual * Off * Off...
  • Page 113: Full Ascii

    SUB $Z ESC %A Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9. Full ASCII On IMAGETEAM™ 2020/4620 System Manual SPACE 0 < %G L %H M >...
  • Page 114: Code 39 Code Page

    The data characters should then appear properly. Code 39 Code Page Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 * On 7 - 10 IMAGETEAM™ 2020/4620 System Manual...
  • Page 115: Check Digit

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual 7 - 11...
  • Page 116: Code 93

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length 7 - 12 IMAGETEAM™ 2020/4620 System Manual...
  • Page 117: Code 93 Code Page

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual 7 - 13...
  • Page 118: Iata Code 2 Of 5

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length 7 - 14 IMAGETEAM™ 2020/4620 System Manual...
  • Page 119: Matrix 2 Of 5

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual 7 - 15...
  • Page 120: Check Digits Required

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length 7 - 16 IMAGETEAM™ 2020/4620 System Manual...
  • Page 121: Isbt 128 Concatenation

    3) a variation of Code 128 that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below to turn concatenation on or off. Default =Off. * Off IMAGETEAM™ 2020/4620 System Manual 7 - 17...
  • Page 122: Code 128 Message Length

    A-6), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Code 128 Code Page Telepen <Default All Telepen Settings> Telepen * Off 7 - 18 IMAGETEAM™ 2020/4620 System Manual...
  • Page 123: Telepen Output

    (page 7-2) for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. Minimum Message Length Maximum Message Length UPC-A <Default All UPC-A Settings> UPC-A * On IMAGETEAM™ 2020/4620 System Manual 7 - 19...
  • Page 124: Upc-A Check Digit

    This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On 5 Digit Addenda On 7 - 20 * 2 Digit Addenda Off * 5 Digit Addenda Off IMAGETEAM™ 2020/4620 System Manual...
  • Page 125: Upc-A Addenda Required

    When turned off, there is no space. Default = On. * On UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. Default = On. * On IMAGETEAM™ 2020/4620 System Manual 7 - 21...
  • Page 126: Upc-E0

    UPC-E0 selection. If you need to read codes that lead with the 1 number system, (page 7-24). Default = On. UPC-E1 * UPC-E0 On UPC-E0 Off UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. * Off 7 - 22 IMAGETEAM™ 2020/4620 System Manual...
  • Page 127: Upc-E0 Addenda Required

    Default = On. * On UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On IMAGETEAM™ 2020/4620 System Manual * Not Required 7 - 23...
  • Page 128: Upc-E0 Number System

    (page 7-22). If you need to read codes that lead with the 1 number system, use the UPC-E1 selection. Default = Off. UPC-E1 On 7 - 24 * 2 Digit Addenda Off * 5 Digit Addenda Off IMAGETEAM™ 2020/4620 System Manual * UPC-E1 Off...
  • Page 129: Ean/Jan-13

    EAN/JAN-13 * On EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On IMAGETEAM™ 2020/4620 System Manual 7 - 25...
  • Page 130: Ean/Jan-13 Addenda

    Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code 7 - 26 * 2 Digit Addenda Off * 5 Digit Addenda Off IMAGETEAM™ 2020/4620 System Manual * Not Required (page 7-21).
  • Page 131: Isbn Translate

    EAN/JAN-8 * On EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On IMAGETEAM™ 2020/4620 System Manual 7 - 27...
  • Page 132: Ean/Jan-8 Addenda

    When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. * On 7 - 28 * 2 Digit Addenda Off * 5 Digit Addenda Off IMAGETEAM™ 2020/4620 System Manual * Not Required...
  • Page 133: Msi

    MSI bar codes printed with the specified type check character, but will not transmit the check character with the scanned data. * Validate Type 10, but Don’t Transmit Validate Type 10 and Transmit IMAGETEAM™ 2020/4620 System Manual 7 - 29...
  • Page 134: Msi Message Length

    Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length 7 - 30 Maximum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual Message * Off Message...
  • Page 135: Rss-14

    RSS-14 < Default All RSS-14 Settings > RSS-14 * On RSS Limited < Default All RSS Limited Settings > RSS Limited * On IMAGETEAM™ 2020/4620 System Manual 7 - 31...
  • Page 136: Rss Expanded

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74. Minimum Message Length Maximum Message Length 7 - 32 IMAGETEAM™ 2020/4620 System Manual...
  • Page 137: Posicode

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual 7 - 33...
  • Page 138: Trioptic Code

    Note: If you are going to scan Code 32 Pharmaceutical codes Trioptic Code must be off. Trioptic Code is used for labeling magnetic storage media. Codablock F <Default All Codablock F Settings> Codablock F 7 - 34 IMAGETEAM™ 2020/4620 System Manual (page 7-8), * Off * Off...
  • Page 139: Codablock F Message Length

    Scan the bar codes below to change the message length. Refer to Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-160. Minimum Default = 1, Maximum Default = 160. Minimum Message Length IMAGETEAM™ 2020/4620 System Manual Message Maximum Message Length * Off Message...
  • Page 140: Code 49

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81. Minimum Message Length Maximum Message Length 7 - 36 IMAGETEAM™ 2020/4620 System Manual...
  • Page 141: Pdf417

    Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. Minimum Message Length Maximum Message Length MicroPDF417 < Default All MicroPDF417 Settings > IMAGETEAM™ 2020/4620 System Manual 7 - 37...
  • Page 142: Micropdf417 Message Length

    Linear codes are combined with a unique 2D composite component to form a new class called EAN•UCC Composite symbology. EAN•UCC Composite symbologies allow for the co-existence of symbologies already in use. 7 - 38 Maximum Message Length IMAGETEAM™ 2020/4620 System Manual * Off Message * Off...
  • Page 143: Upc/Ean Version

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2435. Minimum Default = 1, Maximum Default = 2435. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual 7 - 39...
  • Page 144: Ean Ucc Emulation

    Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected. The linear component may be decoded as Code 39 even if TLC39 is off. 7 - 40 IMAGETEAM™ 2020/4620 System Manual 128 Emulation * Off...
  • Page 145: Postal Codes

    Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data. Transmit Check Digit IMAGETEAM™ 2020/4620 System Manual * Off * Don’t Transmit Check Digit 7 - 41...
  • Page 146: Planet Code

    This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data. Transmit Check Digit British Post Canadian Post 7 - 42 * Don’t Transmit Check Digit IMAGETEAM™ 2020/4620 System Manual * Off * Off * Off...
  • Page 147: Kix (Netherlands) Post

    Note: Kix code can misread when scanned sideways or upside down. Use Working Orientation, page 4-19, if your Kix codes will not usually be presented upright to the imager. Australian Post Japanese Post IMAGETEAM™ 2020/4620 System Manual * Off * Off * Off 7 - 43...
  • Page 148: China Post

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length 7 - 44 IMAGETEAM™ 2020/4620 System Manual...
  • Page 149: Korea Post

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual 7 - 45...
  • Page 150: Qr Code

    Scan the bar codes below to change the message length. Refer to Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-3500. Minimum Default = 1, Maximum Default = 3500. Minimum Message Length 7 - 46 Maximum Message Length IMAGETEAM™ 2020/4620 System Manual * Off Message...
  • Page 151: Data Matrix

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-1500. Minimum Default = 1, Maximum Default = 1500. Minimum Message Length Maximum Message Length IMAGETEAM™ 2020/4620 System Manual 7 - 47...
  • Page 152: Maxicode

    Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150. Minimum Message Length Maximum Message Length 7 - 48 IMAGETEAM™ 2020/4620 System Manual...
  • Page 153: Aztec Code

    Select Enable Runes if you are scanning Aztec runes, which are the smallest type of Aztec Code symbol with the ability to encode a very short license plate message. Enable Runes * Disable Runes IMAGETEAM™ 2020/4620 System Manual 7 - 49...
  • Page 154 7 - 50 IMAGETEAM™ 2020/4620 System Manual...
  • Page 155: Chapter 8 - Imaging Commands

    E - Exposure: This allows you to set the exposure time. Units are 127 microseconds. Exposure is used in Manual Style only. (Default = 7874) Range: 0 - 7874 IMAGETEAM™ 2020/4620 System Manual on page 12-22). When the serial default IMGSNP2G1B...
  • Page 156: Image Ship - Imgshp

    An image is taken whenever the trigger of the IT4620 is pressed, or when the Image Snap (IMGSNP) command is processed. The last image is always stored in memory. You may “ship” the image by using the IMGSHP command. 8 - 2 IMAGETEAM™ 2020/4620 System Manual...
  • Page 157: Imgshp Modifiers

    Uncompressed binary (upper left to lower right, 1 pixel/bit, 0 padded end of line) Uncompressed grayscale (upper left to lower right, bitmap format) JPEG image (default) BMP format (lower right to upper left, uncompressed) IMAGETEAM™ 2020/4620 System Manual IMGSHP8F75K26U 8 - 3...
  • Page 158 The optimal setting for text images is 50K. Gamma correction off (default) Apply gamma correction for brightening typical document image Apply gamma correction factor n ( n = 1-255) 8 - 4 IMAGETEAM™ 2020/4620 System Manual...
  • Page 159 The smaller number of pixels shipped, the smaller the image. However, after a certain point, the image becomes unusable. ship every pixel (default) ship every 2nd pixel, both horizontally and vertically (default) ship every 3rd pixel, both horizontally and vertically IMAGETEAM™ 2020/4620 System Manual 8 - 5...
  • Page 160 This modifier ships the histogram for an image. Don’t ship histogram (default) Ship histogram 8 - 6 page IMGSNP1P0L168W90%32D page 8-6). This filter also works well when IMAGETEAM™ 2020/4620 System Manual 8-4), with the imager in a...
  • Page 161: Intelligent Signature Capture - Imgbox

    IMGBOX40S0X70Y190W100H1R0F IMGBOX Modifiers D - Pixel Depth: Indicates the number of bits per pixel in the transmitted image. 8 bits per pixel, grayscale image 1 bit per pixel, black and white image IMAGETEAM™ 2020/4620 System Manual 0123456789 8 - 7...
  • Page 162 A setting of 100 results in no adjustment to the image. (Default = 50K) Gamma correction off Apply gamma correction for brightening typical document image Apply gamma correction factor n ( n = 1-255) 8 - 8 IMAGETEAM™ 2020/4620 System Manual...
  • Page 163: Rf Default Imaging Device

    Refer to containing the port, work group, imager name, and address for each imager. Refer to "Imager Name" IMAGETEAM™ 2020/4620 System Manual "Quick*View" "Imager Report" on page 11-2 to generate a report on page 3-7 set a unique name for each imager.
  • Page 164 8 - 10 IMAGETEAM™ 2020/4620 System Manual...
  • Page 165: Chapter 9 - Ocr Programming

    “template,” or character string that defines the length and content of OCR strings that will be read with your imager. Note: Setting the template and check character options are essential for OCR reading. IMAGETEAM™ 2020/4620 System Manual 9 - 1...
  • Page 166: Ocr Fonts

    If you have created an OCR template, character combinations that fit the template can be scanned (see Creating an OCR Template, page 9-5). 9 - 2 < Default All OCR Settings > OCR-A On OCR-B On IMAGETEAM™ 2020/4620 System Manual...
  • Page 167: U.s. Currency Font

    T the amount character is output as A the on us character is output as O the dash character is output as D IMAGETEAM™ 2020/4620 System Manual Template, page 9-5). U.S. Currency On Template, page 9-5).
  • Page 168: Semi Font

    You can create a template for a single format, you can string together several formats, and you can create a template for a user-defined variable. These choices are described in detail below. 9 - 4 IMAGETEAM™ 2020/4620 System Manual...
  • Page 169: Creating An Ocr Template

    Use the Sample Codes in the back of this manual) to scan the characters for your template. Example: You need to read any combination of eight digits. The template would IMAGETEAM™ 2020/4620 System Manual (page 9-2). (page 9-14).
  • Page 170 9-14). Scan the d from the (page on the inside back cover (the hex characters for “space,” 551 ABC 983 IMAGETEAM™ 2020/4620 System Manual Codes, page A-6, find the Hex OCR Programming page 9-15. This would let you...
  • Page 171: Stringing Together Multiple Formats (Creating "Or" Statements)

    14). The letters g and h can then be used in an OCR template to define the variable you specified. Example: You need a variable to represent the letters “A,” “B,” or “C.” The template for this variable would be: IMAGETEAM™ 2020/4620 System Manual ddddddddtddddlldd 9-14). Scan the d from the (page 9-15).
  • Page 172: Reading Multi-Row Ocr

    9-14). Scan 414243 from the (the hex characters for “A,” “B,” and “C”). Scan Save 9-15). This will let you read either A or B or C in any ddddddggg 654321ABC 654321BAC 654321CCC 12345678 ABCDEFGH OCRTMP"dddddddd". OCRTMP"llllllll". OCRTMP"ddddddddrllllllll". IMAGETEAM™ 2020/4620 System Manual...
  • Page 173: Ocr Check Character

    0123456 OCR Modulo 10 Check Character Scan this symbol to program the OCR template for a simple modulo 10 checksum of the digits 0 through 9. IMAGETEAM™ 2020/4620 System Manual 12345678 ABCDEFGH ABCD1234. dddddddc...
  • Page 174: Ocr Modulo 36 Check Character

    2. Enter the characters in order. For each character, look up the corresponding hex value from the 9 - 10 OCR Modulo 36 Check Character 0123456789X dddddddc 6512351X Enter OCR Check Character Code Page Mapping of Printed Bar Codes IMAGETEAM™ 2020/4620 System Manual on page A-6.
  • Page 175: Weighting Options

    (0 x 3 + 1 x 1 + 2 x 3 + 3 x 1 + 4 x 3 + 5 x 1 + 6 x 3 + 5 x 1) modulo 10 = 0 Since the result is zero, the message is considered to be valid, so the reader outputs the message: 0123456 IMAGETEAM™ 2020/4620 System Manual on the inside the back cover of this manual to page...
  • Page 176 = (0 + 2 + 2 + (1 + 6) + 4 + (1 + 0) + 4) modulo 10 Since the result is zero, the message is considered to be valid, so the reader outputs the message: 012845 9 - 12 2-1-2-1 Weighted Modulo 10 Check Character ddddddc 0128454 IMAGETEAM™ 2020/4620 System Manual...
  • Page 177: Ocr Isbn Application Example

    (represented by a backslash). 4. Scan the symbol below to set up three templates to handle the ISBN num- ber, the three digit price field, and the four digit price field. IMAGETEAM™ 2020/4620 System Manual bar code on page 9-2.
  • Page 178: Ocr Template Codes

    One or more two-digit numbers and Save are required after reading this programming symbol. Refer to the cover of this manual. 9 - 14 † Programming Chart IMAGETEAM™ 2020/4620 System Manual Enter User-Defined † Variable “g” on the inside the back...
  • Page 179: Exit Selections

    Exit Selections Save OCR Template Discard OCR Template IMAGETEAM™ 2020/4620 System Manual 9 - 15...
  • Page 180 9 - 16 IMAGETEAM™ 2020/4620 System Manual...
  • Page 181: Chapter 10 - Interface Keys

    The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the imager. Refer to page 2-14 enable Control + ASCII mode. Function Code HEX/ASCII Value IMAGETEAM™ 2020/4620 System Manual Full ASCII “CTRL” + 10 - 1...
  • Page 182 The following chart indicates the equivalents of these five characters for different countries. Country United States Belgium Scandinavia France Germany Italy Switzerland United Kingdom Denmark Norway Spain 10 - 2 Codes < < Ã < ¢ IMAGETEAM™ 2020/4620 System Manual...
  • Page 183: Supported Interface Keys

    Reserved Delete CR/Enter Insert Escape Home Print Back Space Back Tab * IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models) IMAGETEAM™ 2020/4620 System Manual IBM XTs and IBM, DDC, Memorex Compatibles Telex, Harris* Supported Keys Supported Keys Reserved Reserved CR/Enter...
  • Page 184 Enter New Line Tab/Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab IMAGETEAM™ 2020/4620 System Manual Memorex Telex (88)** Supported Keys Reserved Enter PF10 PF11 PF12 Reserved Reserved New Line Field Forward Field Forward...
  • Page 185 Supported Interface Keys ASCII IMAGETEAM™ 2020/4620 System Manual Esprit 200, 400 Esprit 200, 400 ANSI ASCII Supported Keys Supported Keys Reserved Reserved New Line New Line New Line New Line New Line New Line Escape Escape Insert Insert Back Space...
  • Page 186 Supported Interface Keys Apple Mac/iMac ASCII Supported Keys Reserved Enter/Numpad Enter CAPS ALT make ALT break CNTRL make CNTRL break RETURN APPLE make APPLE break RETURN Ins Help Home Prnt Scrn BACKSPACE LSHIFT TAB BACKSPACE 10 - 6 IMAGETEAM™ 2020/4620 System Manual...
  • Page 187: Chapter 11 - Utilities

    Scan the bar code below to output the current software revision, unit serial number, and other product information for both the imager and base. Show Revision Show Data Format Scan the bar code below to show current data format settings. Data Format Settings IMAGETEAM™ 2020/4620 System Manual 11 - 1...
  • Page 188: Imager Report

    3-5 for additional information. 11 - 2 "Menu Command Syntax" Imager Report Imager Address Base Address starting on page 12-6 Standard Product Default Settings: Current Application Group IMAGETEAM™ 2020/4620 System Manual on page 12-1. list the factory default settings for "Imager Modes"...
  • Page 189: Resetting The Standard Product Default Settings: All Application Work Groups

    * Off Visual Menu 2003 Visual Menu 2003 provides the ability to configure a Hand Held Products imaging device by connecting the imager to the COM port of a PC. Visual Menu 2003 allows you to download updates to an imager’s firmware, change programmed parameters, and create and print programming bar codes.
  • Page 190: Installing Visual Menu 2003 From The Web

    Resetting the Standard Product Default Settings: Current Application Work Group Installing Visual Menu 2003 from the Web 1. Access the Hand Held Products web site at www.handheld.com. 11 - 4 Visual Menu 2003 on page 11-2. IMAGETEAM™ 2020/4620 System Manual...
  • Page 191: Quick*View

    IMAGETEAM 4620. Bar code information and images are displayed in the Quick*View window. Installing Quick*View from the Web 1. Access the Hand Held Products web site at www.handheld.com. 2. Click on Search and enter Quick*View. 3. Click on Search. 4. Click on the entry for Software. Select Quick*View Software Utility.
  • Page 192 Note: If you have a unit capable of keyboard wedge mode, scan the bar code below and the unit will communicate in RS-232 mode, allowing it to work with Quick*View. To convert the imager back to keyboard wedge communication, cycle the power. 11 - 6 Quick*View IMAGETEAM™ 2020/4620 System Manual...
  • Page 193: Chapter 12 - Serial Programming Commands

    A 3 character case-insensitive field that identifies the desired menu command within the tag group. For example, the SubTag for the RS-232 baud rate is BAD. Data The new value for a menu setting, identified by the Tag and Sub- Tag. IMAGETEAM™ 2020/4620 System Manual 12 - 1...
  • Page 194: Query Commands

    (,) and only the SubTag and Data fields of the additional command are issued. If the additional command requires a different Tag field, the command is separated from previous commands by a semicolon (;). 12 - 2 IMAGETEAM™ 2020/4620 System Manual...
  • Page 195: Responses

    (CBRENA) is 1, or on. Example #3: What is the device’s current setting for Codabar Coding Enable? Enter: cbrena?. Response: CBRENA1[ACK] This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on. IMAGETEAM™ 2020/4620 System Manual 12 - 3...
  • Page 196: Trigger Commands

    The imager scans until a bar code has been read, until the deactivate command is sent, or until the serial time-out has been reached (see "Read Time-Out (Serial Trigger Mode)" on page 4-4 for a description, and the serial command on page 12-10). 12 - 4 IMAGETEAM™ 2020/4620 System Manual...
  • Page 197: Resetting The Standard Product Default Settings: Current Application Work Group

    Standard Product Default Settings: Menu Commands settings for each of the commands (indicated by an asterisk (*) on the programming pages). IMAGETEAM™ 2020/4620 System Manual starting on page 12-6 list the factory default settings for Standard Product Default Settings: Current Application Group...
  • Page 198: Menu Commands

    Latin America Netherlands (Dutch) Norway Poland Portugal Romania Russia Slovakia Spain Sweden Switzerland (German) Turkey F Turkey Q U.K. IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry TERMID### KBDCTY0 2-11 KBDCTY1 2-11 KBDCTY16 2-11 KBDCTY18 2-11...
  • Page 199 Selection Keyboard Style Keyboard Modifiers Baud Rate Word Length: Data Bits, Stop Bits, and Parity IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default *Regular Caps Lock Shift Lock Automatic Caps Lock Emulate External Keyboard *Control + ASCII Off Control + ASCII On...
  • Page 200 *ACK/NAK Off ACK/NAK On Same Code Format Code 39 Format *50ms 150ms 500ms *Off *Black High White High Idle Low *Idle High IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry 232LPT### 2-18 232CTS0 2-18 232CTS2 2-18...
  • Page 201: Basic System Operation

    Work Group Standard Product Defaults: All Application Work Groups Non-Base Bluetooth Connection Bluetooth PIN Code Out-of-Range Alarm IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default *Automatic Full Charge Rate Low Charge Rate Battery Charge Off Unlink Imager *Locked Link Mode...
  • Page 202: Output Selections

    Medium Delay (1000 ms) Long Delay (1500 ms) Range 0 - 30,000 ms *Manual/Serial Trigger Read Time-Out (0 - 300,000 ms) *300,000 Imager Power Time-Out Timer (0-7200 seconds) *3600 IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry BASORW 3-12...
  • Page 203 Reread Delay User-Specified Reread Delay LED Power Level Illumination Lights Aimer Delay User-Specified Aimer Delay Aimer Mode IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default Scan Stand Mode Scan Stand Symbol Presentation Mode LEDs Off *LEDs On Range 0-20 (*1)
  • Page 204: Prefix/Suffix Selections

    On/Not Required *Off *Off *Off Set Print Weight (1-7) *Default (4) *Off *Upright ° Rotate Clockwise 90 Upside Down Rotate Counterclockwise 90 IMAGETEAM™ 2020/4620 System Manual Serial Command # Indicates a numeric entry DECWIN1 DECWIN0 DECLFT DECRGT DECTOP DECBOT DECMOD0...
  • Page 205: Data Formatter Selections

    Data Formatter Selections Data Format Editor Data Formatter Alternate Data Formats Symbologies All Symbologies Codabar Codabar IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default Add Prefix Clear One Prefix Clear All Prefixes Add Suffix Clear One Suffix Clear All Suffixes...
  • Page 206 Transmit Minimum (0 - 48) *0 Maximum (0 - 48) *48 *Off *Off *Off Code 39 Code Page Default All Interleaved 2 of 5 Settings IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry CBRSSX0 CBRSSX1 CBRCK20...
  • Page 207 Length Matrix 2 of 5 Matrix 2 of 5 Matrix 2 of 5 Message Length Code 11 Code 11 IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default *No Check Char. Validate, But Don’t Transmit Validate, and Transmit Minimum (2 - 80) *4...
  • Page 208 Settings *Off *AIM Telepen Output Original Telepen Output Minimum (1 - 60) *1 Maximum (1 - 60) *60 Default All UPC-A Settings *Off *Off IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry C11CK20 7-16 C11CK21 7-16...
  • Page 209 Required UPC-E0 Addenda Sepa- rator UPC-E0 Check Digit UPC-E0 Number System UPC-E0 Addenda UPC-E1 EAN/JAN-13 EAN/JAN-13 EAN/JAN-13 Check Digit IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default *Not Required Required Default All UPC-E Settings *Off Required *Not Required 2 Digit Addenda On...
  • Page 210 *Off *Validate Type 10, but Don’t Transmit Validate Type 10 and Transmit Minimum (4 - 48) *4 Maximum (4 - 48) *48 Default All Plessey Settings IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry E13AD21 7-26...
  • Page 211 Length PosiCode PosiCode PosiCode Msg. Length Trioptic Code Codablock F Codablock F Codablock F Msg. Length IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default *Off Minimum (4 - 48) *4 Maximum (4 - 48) *48 Default All RSS-14 Settings Default All RSS-14...
  • Page 212 Minimum (1-2435) *1 Maximum (1-2435) *2435 RSS Emulation EAN • UCC-128 Emulation • *EAN UCC Emulation Off *Off *Off Transmit *Don’t Transmit IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry 16KDFT 7-35 16KENA0 7-35 16KENA1 7-35...
  • Page 213 China Post Msg. Length Korea Post Korea Post Korea Post Msg. Length QR Code QR Code QR Code Msg. Length Data Matrix Data Matrix IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default *Off Transmit *Don’t Transmit *Off *Off *Off *Off...
  • Page 214: Imaging Default Commands

    Imaging Style - Manual Beeper On *Beeper Off Exposure *Gain - None Gain - Medium Gain - Heavy Gain - Maximum Delta for Acceptance (0-255) IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry IDMMIN 7-47 IDMMAX...
  • Page 215: Image Snap (Continued)

    Selection Image Snap (continued) IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default *LED State - Off LED State - On *Wait for Trigger Off Wait for Trigger On Update Tries (0-10) *6 Target White Value (0-255) *125 Target Set Point Percentage...
  • Page 216 JPEG Image Quality (0-100) *Gamma Correction Off Gamma Correction On (1-255) Image Crop - Left (0-640) *0 Image Crop - Right (0-640) *639 Image Crop - Top (0-480) *0 IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry IMGINF0...
  • Page 217: Ocr Selections

    Selection Image Ship (continued) OCR Selections IMAGETEAM™ 2020/4620 System Manual Setting * Indicates default Image Crop - Bottom (0-480) *479 Image Crop - Margin (1-238) Protocol - None (raw) Protocol - None (default USB) Protocol - Hmodem Protocol - Hmodem Com-...
  • Page 218 OCR User-Defined Check Char. 3-1-3-1 Weighted Mod. 10 Check Char. 2-1-2-1 Weighted Mod. 10 Check Char. Enter OCR Template Enter User-Defined Variable g Enter User-Defined Variable h IMAGETEAM™ 2020/4620 System Manual Serial Command Page # Indicates a numeric entry “OCRCHK01234 56789” “OCRCHK01234...
  • Page 219: Chapter 13 - Product Specifications

    Data Range Temperature Ranges: Operating Battery Charge Storage* Humidity Mechanical Drop Vibration IMAGETEAM™ 2020/4620 System Manual Specification 6.2 inches (15.7 cm) 5.3 inches (13.5 cm) 3.2 inches (8.1 cm) 9.2 ounces (260.8 g) 626nm +30nm 526nm +30nm VGA, 640x480. Binary, TIFF, or JPEG output.
  • Page 220: Imageteam 2020-5B Product Specifications

    ESD Sensitivity MTBF Sealant Rating *Storage outside of this temperature range could be detrimental to battery life. IMAGETEAM 2020-5B Product Specifications Parameter Dimensions (Typical): Height Length Width Weight Voltage: DC Barrel Host Port Current Draw: 5 Volt Host 9 Volt DC Barrel...
  • Page 221: Standard Cable Pinouts

    Standard Cable Pinouts Keyboard Wedge IMAGETEAM™ 2020/4620 System Manual 13 - 3...
  • Page 222 Standard Cable Pinouts Wand Emulation 13 - 4 IMAGETEAM™ 2020/4620 System Manual...
  • Page 223 Standard Cable Pinouts Serial Output IMAGETEAM™ 2020/4620 System Manual 13 - 5...
  • Page 224 Standard Cable Pinouts 13 - 6 IMAGETEAM™ 2020/4620 System Manual...
  • Page 225: Chapter 14 - Maintenance

    Inspect the base’s interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with imager operation. Contact your Hand Held Products distributor for information about cable replacement. Cable replacement instructions are on IMAGETEAM™...
  • Page 226: Replacing The It2020-5B Interface Cable

    • The power cable is connected properly and there is power at the power source. • The host system power is on (if external power isn’t used). Is the green LED on? 14 - 2 IMAGETEAM™ 2020/4620 System Manual End Cap...
  • Page 227 For example, you scan “12345” and the host displays “A12345B.” Reprogram the base with the proper symbology selections. See The imager won’t read your bar code at all. IMAGETEAM™ 2020/4620 System Manual (See "Base Charge Mode" on page on page 5-1 for further information.
  • Page 228 Verify that your bar code symbology is enabled (see 2. If the imager still can’t read the sample bar codes, scan page 7-2. 14 - 4 IMAGETEAM™ 2020/4620 System Manual Chapter All Symbologies...
  • Page 229: Chapter 15 - Customer Support

    Hand Held Products provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, return the unit to Hand Held Products (postage paid) with a copy of the dated purchase record attached. Contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product.
  • Page 230: Technical Assistance

    Technical Assistance If you need assistance installing or troubleshooting your imager, please call your Distributor or the nearest Hand Held Products technical support office: North America/Canada: Telephone: (800) 782-4263, option 4 (8 a.m. to 6 p.m. EST) Fax number: (315) 685-4960 E-mail: natechsupport@handheld.com...
  • Page 231: Limited Warranty

    (C) static electricity or electro-static discharge, (D) operation under conditions beyond the specified operating parameters, or (E) repair or service of the product by anyone other than Hand Held Products or its authorized representatives. This warranty shall extend from the time of shipment for the duration published by Hand Held Products for the product at the time of purchase ("Warranty...
  • Page 232 These warranties are nontransferable. The limited duration of the warranty for the IT2020-5B and IT4620 is for three (3) years. The limited duration of the warranty for the imager battery is for one (1) year. 15 - 4 IMAGETEAM™ 2020/4620 System Manual...
  • Page 233: Symbology Chart

    Coupon Code Interleaved 2 of 5 Japanese Post KIX (Netherlands) Post Korea Post Matrix 2 of 5 MaxiCode IMAGETEAM™ 2020/4620 System Manual Possible AIM ID Modifiers ( m ) ]z m 0-9, A-C ]F m ]O m 0, 1, 4, 5, 6...
  • Page 234: Hand Held

    ]p m 0, 1, 2 ]Q m ]e m ]R m 0, 1, 3 0, 1, 3 ]B m 0, 1, 2, 4 IMAGETEAM™ 2020/4620 System Manual Hand Held Products Code ID (hex) R (0x52) g (0x67) (0x9C) O (0x4F)
  • Page 235 Note: Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Refer to Data Editing beginning on page 5-1 and page 6-1 for information about using Code ID and AIM ID. IMAGETEAM™ 2020/4620 System Manual Data Formatting beginning on A - 3...
  • Page 236: Ascii Conversion Chart (Code Page 1252)

    ASCII Conversion Chart (Code Page 1252 Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings. Char A - 4 Char “ & ‘ < > IMAGETEAM™ 2020/4620 System Manual Char Char ‘...
  • Page 237 Š ‹ Œ Ž ‘ ’ “ ” • – — ˜ ™ š › œ ž Ÿ IMAGETEAM™ 2020/4620 System Manual Dec. Char Dec. ¡ ¢ £ ¤ ¥ ¦ § ¨ © ª « ¬ ® ¯ °...
  • Page 238: Code Page Mapping Of Printed Bar Codes

    Description Automatic National Replacement Charac- ters Swedish Replacement Characters French/Belgium Replacement Characters French/Belgium Replacement Characters German Replacement Characters Italian Replacement Characters Swiss Replacement Characters British Replacement Characters Danish Replacement Characters Norwegian Replacement Characters Spanish Replacement Characters IMAGETEAM™ 2020/4620 System Manual...
  • Page 242 Sample Symbols UPC-A Interleaved 2 of 5 0 123456 7890 Code 128 1234567890 EAN-13 Code 128 Code 39 9 780330 290951 Codabar BC321 Code 93 A13579B Code 2 of 5 123456-9$ 123456...
  • Page 243 Sample Symbols Matrix 2 of 5 RSS-14 6543210 PDF417 (01)00123456789012 Postnet Car Registration Zip Code Code 49 Data Matrix 1234567890 QR Code Test Symbol Numbers...
  • Page 244 Sample Symbols Aztec Micro PDF417 Package Label MaxiCode Test Message OCR-A with Modulo 10 check character Test Message OCR-A with Modulo 36 check character...
  • Page 245: Ocr Programming Chart

    OCR Programming Chart Discard Save...
  • Page 246: Programming Chart

    Programming Chart...
  • Page 247 Programming Chart Save Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again. Discard...
  • Page 248 Hand Held Products, Inc. 700 Visions Drive P.O. Box 208 Skaneateles Falls, NY 13153-0208 4620B-SM Rev A 4/05...

This manual is also suitable for:

Imageteam 4620Imageteam 2020It2020-5bIt4620

Table of Contents