Advertisement

Quick Links

STRENGTH
| CARDIO | FUNCTIONAL
AIR300
LEG EXTENSION PRO
MODEL 1133XX
OPERATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LEG EXTENSION PRO AIR300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Keiser LEG EXTENSION PRO AIR300

  • Page 1 STRENGTH | CARDIO | FUNCTIONAL AIR300 LEG EXTENSION PRO MODEL 1133XX OPERATION MANUAL...
  • Page 2: Table Of Contents

    Distribution and copying of this document, use and communication of its contents is not permitted without written authorization from Keiser Corporation. The content of this document is furnished for informational use only, may be subject to change without notice, and should not be construed as a commitment by Keiser Corporation.
  • Page 3: General Information

    Air300 Leg Extension Pro after reading this manual, our Keiser Customer Support team will be happy to assist by telephone at 1 559 256 8000 and via live chat at keiser.com/support (Monday—Friday, 9 am to 5 pm Pacific Time), or by email at service@keiser.com.
  • Page 4: Important Safety Information

    AIR300 LEG EXTENSION PRO OPERATION MANUAL IMPORTANT SAFETY INFORMATION It is the sole responsibility of the purchaser of Keiser Corporation 14. Never perform Power Test without a proper warm-up. This equipment to instruct all individuals, whether they are the end- high resistance/high-speed test should only be performed user or supervising personnel, on proper usage of the equipment.
  • Page 5 SAFETY AND NOTIFICATION LABELS 001133XX 888888-88888 SEAT SEAT Maintain and do not remove safety or notification labels for any reason. They contain important information. If unreadable or missing, contact Keiser Corporation for a replacement (see back cover for contact information).
  • Page 6: Technical Specifications

    • 1.5V D Alkaline Batteries (quantity 2, Keiser PN 966500) • 3V CR2032 Lithium Coin Cell Battery (quantity 1) Permanently attached, not serviceable. Contact Keiser Customer Support for service. KEISER CHIP SYSTEM • The eChip insertion slot receives the Keiser eChip (electronic memory chip) for data transfer and storage...
  • Page 7: Installation And Placement

    Keiser Small Air Compressor source to power the Compressor ON (allow the Compressor to build up to a minimum of 100 psi / 6.89 bar; Keiser Compressor and Keiser Air System not included, sold separately) Keiser 2. Connect the 1/4-inch Quick Disconnect (QD)
  • Page 8: Operation

    AIR300 LEG EXTENSION PRO OPERATION MANUAL OPERATION EQUIPMENT OVERVIEW Figure 5. Air300 Leg Extension Pro Power Display Processor Box Exercise Arms Seat Lever Leg Cushions Increase/Decrease (+/-) Thumb Buttons Anti-Slip Steps eChip Cylinders Seat Back Belts Seat Quick Disconnect (QD) with Tube Instruction Placard (not shown) Air Tanks...
  • Page 9: 09_Power Display

    AIR300 LEG EXTENSION PRO OPERATION MANUAL POWER DISPLAY SEAT SEAT When using the eChip, ensure that it is fully inserted into the slot as shown. Figure 6. Power Display Overview CAUTION Rate monitoring systems may be inaccurate. Over Use of the exercise Target program requires medical exercising may result in serious injury or death.
  • Page 10: 10_Display Features

    Keiser eChip software allows saved eChip data to be viewed, stored, and exported (.csv file format) for analysis. NOTE: Three user eChips (red color) come standard with your Air300 Leg Extension Pro. The Keiser USB Power Kit (a USB adapter to transfer data from your eChip to your computer and Time Set eChips to set the time zone/time on your Air300 Leg Extension Pro) is available.
  • Page 11: 11_Proper Operation Check

    Immediately replace damaged, worn, or broken parts. Do not use the Air300 Leg Extension Pro until all repairs have been completed and tested by a Keiser-certified technician. * “Lo-bA” = Batteries are low, replace immediately. If batteries are dead (depleted), the Power Display remains blank (see...
  • Page 12: 12_How To Use The Air300 Leg Extension Pro

    AIR300 LEG EXTENSION PRO OPERATION MANUAL HOW TO USE THE AIR300 LEG EXTENSION PRO Pull the Seat Back forward, or lift the lever to move backward, so your knees align with the machine pivot point. 2. Grasp the Handgrips and adjust the resistance with the Thumb Buttons. ADJUST EXERCISE Pivot Point...
  • Page 13 AIR300 LEG EXTENSION PRO OPERATION MANUAL HOW TO USE THE AIR300 LEG EXTENSION PRO (CONTINUED) CAUTION • Consult your physician before beginning any exercise • If you feel pain, faintness, or are unable to maintain program. good form, stop immediately. •...
  • Page 14: 14_Power Test

    TEST PROTOCOL — The Power Test (KEISER Six-Rep Test) is used to determine the resistance at which you achieve MAXIMUM POWER. The test consists of two sets: Three repetitions Three repetitions...
  • Page 15: Maintenance

    CAUTION: THE HIGHEST LEVEL OF EQUIPMENT SAFETY CAN ONLY BE ENSURED IF THE EQUIPMENT IS REGULARLY INSPECTED FOR DAMAGE AND WEAR. Immediately replace damaged, worn, or broken parts. Do not use the Air300 Leg Extension Pro until all repairs have been completed and tested by a Keiser-certified technician. •...
  • Page 16: 16_Battery Replacement

    AIR300 LEG EXTENSION PRO OPERATION MANUAL BATTERY REPLACEMENT Do not operate the equipment during battery replacement procedure. “Lo-bA” = Batteries are low, replace immediately. NOTE: If batteries are dead (depleted), the Power Display remains blank. To replace the batteries, refer to Figure 10 and follow the instructions below (no tools required).
  • Page 17: 17_Annual Maintenance

    THE AIR IN THE EQUIPMENT (“— ” THUMB BUTTON) BEFORE PERFORMING ROUTINE MAINTENANCE. Figure 11. Annual Routine Maintenance Illustration Contact Keiser Customer Support for replacement part(s) order, or for any matters regarding the safe operation of your Air300 Leg Extension Pro (see back cover for contact information).
  • Page 18: Regulatory And Compliance Notices

    AIR300 LEG EXTENSION PRO OPERATION MANUAL REGULATORY AND COMPLIANCE NOTICES Standards ISO/EN 20957-1 Accuracy Class A (High accuracy) and Usage Class S (Studio, commercial use); IEC/EN 60601-1 and IEC/EN 60601-1-2. Marks SAFETY NOTIFICATIONS Displayed watts testing parameters: “Current Power,” “Peak Power,” and “Percent of Peak Power” are not suitable for use in applications where the health and safety of a patient may be dependent on the accuracy of those parameters.
  • Page 19: 19_Electromagnetic Compatibility (Emc)

    Wear parts: After being replaced, wear parts must be disposed of according to country-specific waste laws. If you have any questions about equipment disposal, please contact your local dealer or Keiser Customer Support (see back cover for contact information).
  • Page 20: Warranty Statement

    View or print your Air300 Leg Extension Pro warranty online at keiser.com/support/warranty. If you have any questions about your warranty, please contact Keiser Customer Support at 1 559 256 8000 and via live chat at keiser.com/support (Monday—Friday, 9 am to 5 pm Pacific Time), or by email at service@keiser.com.

Table of Contents