Type Tests And Environmental Conditions; Type Tests And Environmental Conditions - Advantech SmartStart SL305 User Manual

Hide thumbs Also See for SmartStart SL305:
Table of Contents

Advertisement

7.4 Type Tests and Environmental Conditions

Phenomena
ESD
Radiated RF immu-
nity
Fast transient
Surge
RF conducted
Voltage dips, interrup-
tions
Dry heat
Cold
Damp heat
Temperature variation
Vibration
Shock
Isolation
Table 14: Type tests and environmental conditions
Test
Description
EN 61000-4-2
Enclosure
Enclosure
EN 61000-4-3
Enclosure
EN 61000-4-4
Power port
Ethernet port
RS485 port
I/O port
AC-DC
EN 61000-4-5
Ethernet port
Power port
AC-DC
EN 61000-4-6
All ports
AC-DC
EN 61000-4-11
AC-DC
EN 60068-2-2
Operation
Storage
EN 60068-2-1
Operation
Storage
EN 60068-2-30,
+55 C / +25 C, 6 h – 6 h, 2 cycles
test Db
EN 60068-2-14 Nb
-40 C / +75 C, 3 h / 3 h, 2 cycles, 3 K/min
EN 60068-2-64 ed. 2
Transport. box
DIN rail
direct mounting
EN 60068-2-27 ed. 2
half-sine, 15 g peak, 11 ms, 6 pulses per axis
Ethernet port
30
SmartStart SL305
Test levels
AC port
6 kV (crit. A)
DC port
8 kV (crit. A)
10 V/m, 80mHz - 6 GHz
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. A)
1 kV (crit. A), shielded cab.
0,5 kV (crit. A)
1 kV (crit. A) L-L
10 V (crit. A)
(0,15 – 80 MHz)
10 V (crit. A)
+75 C, 40 % rel. humidity,
16 hours
+85 C, 40 % rel. humidity,
16 hours
-40 C, 16 hours
-40 C, 16 hours
3 axis, 1 hour per axis
3 axis, 0.5 hour per axis
3 axis, 8 hours per axis
1.5 kV

Advertisement

Table of Contents
loading

Table of Contents