Maintenance and Troubleshooting

FrameSaver 9120 Access Unit

5-2
Label
Indication
1
OK
Power and
Operational
Status
ALM
Operational
Alarm ( Fail )
1
When an ISDN BRI DBM is installed, if the OK LED comes on during power recycling,
then goes off, the ISDN BRI DBM has probably failed.
May 1998
Color
What It Means
Green
ON – Access unit has power and is
operational.
OFF – Access unit is in a power-up self-test,
or there is a failure.
Blinking ON and OFF ( Rate: 1 Hz ) –
Software is being downloaded.
Red
ON – Access unit has just been reset, or an
error or fault has been detected.
Error/fault/alarm conditions:
Out of Frame ( OOF )
Loss of Signal (LOS)
Alarm Indication Signal (AIS)
Exceeded Error Rate (EER)
Yellow Alarm Signal
Device Fail
DBM Card Failed
Memory Failed
T1 Failed
CPU Failed
ISDN Network Failed
LMI Down
DLCI Down
Network Communication Link Down
CTS Down to device
DTR Down to device
Download Failed
Primary or Secondary Clock Failed
OFF – No failures have been detected.