System Configuration; About Control Systems - Daikin VAM-J8 Series Manual

Heat reclaim ventilation unit
Hide thumbs Also See for VAM-J8 Series:
Table of Contents

Advertisement

16
|

System configuration

16 System configuration
Table of Contents

16.1 About control systems

Independent system control system
Basic method to operate the VAM unit.
Available functions in case of an independent system control system:
Ventilation mode changeover: automatic or manual
Air flow rate changeover: high/low
Air flow rate mode changeover: normal mode/fresh-up mode: initial setting required
Malfunction display
Linked operation control system
Linked operation with air conditioner by controller for air conditioner. Maximum 16 units.
The VAM unit can also be operated independently by the controller for the air conditioner, even if the air
conditioner is NOT in operation. The VAM unit CANNOT be operated independently when the duct is
connected directly to the air conditioner.
Available functions in case of a linked operation control system:
Ventilation mode changeover: automatic or manual
Air flow rate changeover: high/low
Air flow rate mode changeover: normal mode/fresh-up mode: initial setting required
Precool/preheat operation: initial setting required
Nighttime free cooling operation: initial setting required
Malfunction display
For an overview of settings, see
"17.2 Field
settings" [
Unified ON/OFF controller: Maximum 16 groups of units.
Schedule timer: 1 schedule timer can control the weekly schedule of 128 units.
Central controller: Up to 64 groups of units can be controlled individually by 1 central controller.
Available functions in case of a central control system:
Ventilation mode changeover: automatic or manual
Air flow rate changeover: high/low
Air flow rate mode changeover: normal mode/fresh-up mode (field setting required when controller for heat
reclaim ventilation unit is NOT used)
Air flow rate mode changeover: normal mode/fresh-up mode (when controller for VAM unit is installed)
Precool/preheat operation: initial setting required
Nighttime free cooling operation: initial setting required
Malfunction display
For an overview of settings, see
"17.2 Field
settings" [
Installer and user reference guide
64
16.1
About control systems............................................................................................................................................................
16.2
Independent system...............................................................................................................................................................
16.3
Linked operation control system............................................................................................................................................
16.4
Central control system ...........................................................................................................................................................
16.5
EKVDX option ..........................................................................................................................................................................
4
 72].
Central control system
4
 72].
a Controller
b Heat reclaim ventilation unit (VAM)
c Air conditioner
d Unified ON/OFF controller, Schedule timer, Central controller
Central
Unified ON/OFF
Schedule timer
controller
controller
Central
Unified ON/OFF
Schedule timer
controller
controller
c
a
Central
Unified ON/OFF
Schedule timer
controller
controller
c
a
b
Controller for
Controller for air
Operation/stop
VAM
conditioner
b
a
Controller for
Controller for air
Operation/stop
VAM
conditioner
b
b
Controller for
Controller for air
Operation/stop
VAM
conditioner
c
d
a
b
a
VAM350~2000J8VEB
Heat reclaim ventilation unit
4P664012-1 – 2021.08
64
65
65
66
67