Combining Units And Options; Possible Options For The Outdoor Unit; Possible Options For The Indoor Unit - Daikin Altherma 3 R F Installer's Reference Manual

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

5
|
About the units and options

5.2 Combining units and options

5.2.1 Possible options for the outdoor unit

5.2.2 Possible options for the indoor unit

Installer reference guide
28
Code
E
European model
BV
Floor-standing indoor unit (refrigerant split) with integrated
tank
X
H=Heating only
X=Heating/cooling
16
Capacity class
S
Integrated tank material: Stainless steel
23
Integrated tank volume
DJ
Model series
6V
Backup heater model
INFORMATION
Certain options might NOT be available in your country.
None.
Multi-zoning wired controls
You can connect the following multi-zoning wired controls:
Multi-zoning base unit 230 V (EKWUFHTA1V3)
Digital thermostat 230 V (EKWCTRDI1V3)
Analogue thermostat 230 V (EKWCTRAN1V3)
Actuator 230 V (EKWCVATR1V3)
For installation instructions, see the installation manual of the control, and the
addendum book for optional equipment.
Room thermostat (EKRTWA, EKRTR1)
You can connect an optional room thermostat to the indoor unit. This thermostat
can either be wired (EKRTWA) or wireless (EKRTR1).
For installation instructions, see the installation manual of the room thermostat
and addendum book for optional equipment.
Remote sensor for wireless thermostat (EKRTETS)
You can use the remote indoor temperature sensor (EKRTETS) only in combination
with the wireless thermostat (EKRTR1).
For installation instructions, see the installation manual of the room thermostat
and the addendum book for optional equipment.
Description
ERLA11~16DAV3+W1 + EBVH/X11+16S18+23DJ
Daikin Altherma 3 R F
4P643602-1 – 2021.09

Advertisement

Table of Contents
loading