Pumps with motor sizes 7.5 - 45 kW
Valid for all types of sourced motors. Not valid for
Grundfos MG and MGE.
Lift the product by means of the lifting brackets on
the motor flange.

4. Installation requirements

4.1 Location

The product is intended for indoor use. If you install
the product outdoors, follow the requirements in the
section on outdoor installation.
Related information
4.1.1 Outdoor installation
4.1.1 Outdoor installation
When the pump is installed outdoors, we recommend
that you provide the motor with a rain cover. We also
recommend that you open one of the drain holes in
the motor flange.
Related information
4.1 Location

5. Mechanical installation

WARNING
Moving parts
Death or serious personal injury
Tighten the coupling screws to the cor-
rect torque.
Install the coupling guards securely to
the pump with the screws intended for
this purpose.
CAUTION
Hot surface
Minor or moderate personal injury
The product must be installed so that
persons cannot accidentally come into
contact with the hot surface of the mo-
tor.

5.1 Mounting the product

The pump is designed for tank mounting in vertical
position. For horizontal mounting, see the section on
MTR version H.
The pump is positioned in a hole cut into the tank and
is secured to the tank by four hexagon head screws
through the holes in the mounting flange.