Using the DSES safety system
The DSES WIRELESS system is available as standard, which means that the function is active
by default. Regular system checks and calibration are required to check it is in working
order.
When powering on,
check that all LEDs are
in working order
During use, the DSES can be inactive with the status LED red in 2 possible cases:
Momentary and deliberate stop:
0.3 s
Continuous and deliberate stop:
10 s
During use, the DSES status LED
is off
= DSES is active
The DSES is inactive for one cut and then
automatically reactivates:
The DSES is permanently disabled. To re-
enable it, a 10s long press on the settings
button is required.
DSES
ACTIVE
During use, the DSES status
LED is red
= DSES is inactive.
You are not protected.
You are not protected during the
single cut.
You are no longer protected.
DSES
INACTIVE