3.
While keeping the trigger pressed, place the bottom of the hook in direct contact with
the tips of the fingers on the hand opposite the one holding the pruning shears, whether
wearing an INFACO conductor glove or not depending on your work configuration.
4.
Move over the entire surface of the hand and/or glove in this way (palm of the hand
and the five fingers, inside and outside) while keeping the trigger pressed to check the
different conductivity levels of your hand, whether gloved or not, using the bar graph:
Conductivity
level
LED and
Bar graph
5.
When the entire surface has been checked, release the trigger at the area of
minimum conductivity while maintaining contact between the hook and the gloved
or ungloved hand. The calibration is complete. The pruning shears switch back to
standby mode.
Never carry out an operation check by trying to cut the glove, follow the
procedure described above. The risk would be to damage your glove.
DSES check and calibration
Excellent
Good
Acceptable
Low
Insufficient
25