contents Warnings before use Setting up System operation check System shutdown Additional functions DSES fault indication Very important...
Page 3
The supplied hard-wired safety system requires special pruning shear settings to operate. IT IS THEREFORE ESSENTIAL to contact an approved INFACO dealer to set up this option. Using the pruning shear with this safety system will disable the WIRELESS safety...
Warnings before use It is mandatory for users to wear a conductor glove (INFACO brand) on the hand not holding the pruning shear. The conductor glove sends data to the electronics to open the pruning shear blades if it comes into contact with the cutting head.
Page 6
CONNECTIONS Place the battery on the vest Pass the cables inside the straps: • pass the tab cable • pass the pruning shear socket cable • pull out the entire cable lengths...
Page 7
Connect the battery socket cable to the battery Turn the vest around and pass the tab cable through the strap loop.
Page 8
CARRYING Once the installation is complete: • Put on the vest • Close the front belt • Adjust the straps for comfort...
Page 9
1. Put on the arm-band 3. Attach the tab to the glove hook and loop attachment 2. Put on the glove...
Page 10
CORRECT TAB LOCATION: 1. Put on the glove 2. Attach the tab 3. Wrap the elastic around the wrist passing over first, then under 4. Attach the hook and loop...
System operation check Check that the DSES system is operational each time the device is started and after a half-day. To do that: Power on the pruning shear by pressing the ON / OFF button: ON/OFF Button Pruning shear power supply socket Or put the pruning shears on standby:...
Page 12
After one second, press the trigger and keep it pressed, the DSES check mode is activated. The DSES LED flashes, the power LED turns steady red. While keeping the trigger pressed, put the bottom of the hook in direct contact with the conductor glove fingertips.
Page 13
Check the cutting head cleanliness. Dirt can alter both the conductivity and the correct operation of the safety system. INFACO cannot be held liable for failures caused by gloves in poor condition. Release the trigger, the test is complete.
System shutdown The safety system can be temporarily or permanently disabled using the procedure below: • Momentary and deliberate stop: The DSES is inactive for one cut and then 0.3 s automatically reactivates: You are not protected during the single cut.
Level 3: Maximum safety, the user cannot operate the “momentary” and “continuous” stop functions. Moreover, if a safety system malfunction is detected, the pruning shear cannot be used. These three safety levels can be activated using your Infaco dealer’s reading interface. DSES fault indication...
Page 16
The DSES LED is steady red and the user has not momentarily or permanently disabled the system: there is a fault. Check that the tab is properly fixed to the hook and loop on the conductor glove. Check the DSES wire condition. Restart your pruning shear and check the DSES operation using the procedure (“Checking correct operation”...
Very important For the DSES system to operate correctly, it is essential to wear the INFACO CONDUCTOR GLOVE. If the conductor glove is too worn or damaged, it must be replaced. It is our duty to remind you of the instructions for use.
Page 18
Do not work with the tool if you are tired or feeling unwell. It is strictly prohibited to modify or repair the glove structure (stitching, adding parts, etc.). INFACO cannot be held liable for failures caused by alterations to the gloves. see page 11)
Page 20
w w w . i n f a c o . c o m User guide - DSES SAFETY SYSTEM NOT_DSES_F3020_US_02_22...