Vapormed Volcano MEDIC 2 Instructions For Use Manual

Vapormed Volcano MEDIC 2 Instructions For Use Manual

Hide thumbs Also See for Volcano MEDIC 2:
Table of Contents

Advertisement

Quick Links

Manufacturer and Distributor:
S T O R Z & B I C K E L G M B H & C O. K G
In Grubenäcker 5-9 · 78532 Tuttlingen / Germany
Phone +49-74 61- 96 9707- 0 · Fax +49 -74 61-96 97 07- 7
e-mail: info@vapormed.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Volcano MEDIC 2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vapormed Volcano MEDIC 2

  • Page 1 S T O R Z & B I C K E L G M B H & C O. K G In Grubenäcker 5-9 · 78532 Tuttlingen / Germany Phone +49-74 61- 96 9707- 0 · Fax +49 -74 61-96 97 07- 7 e-mail: info@vapormed.com...
  • Page 2 INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions.
  • Page 3: Table Of Contents

    Operating Conditions .............. 22 7.3. MEDIC VALVE Balloon..............39 4.2. Storage and Transport Conditions ........22 7.3.1. Application..............40 5. The VOLCANO MEDIC 2 Hot Air Generator........23 7.3.2. Inhalation ..............42 5.1. Unpacking .................. 23 7.4. Application Part: Tube Kit............44 5.2.
  • Page 4 10.4. In Case of Problems ............... 58 9.1. General ..................49 10.5. Disposal ..................58 9.2. Material Resistance of the VOLCANO MEDIC 2 Vaporization System ..............49 10.6. Troubleshooting ............... 59 9.3. Filling Chamber as well as Tube Flexer 10.7. Technical Specifications of the VOLCANO MEDIC 2 and Mouthpiece of the Tube Kit..........50...
  • Page 5: Product Overview, Scope Of Delivery

    1. PRODUCT OVERVIEW, SCOPE OF DELIVERY, SERVICE 1. PRODUCT OVERVIEW, SCOPE OF DELIVERY, SERVICE 1.1. Product Overview VOLCANO MEDIC 2 Hot Air Generator Filling Chamber Cap Ring Normal Screen Set (Ø 30 mm) Application Part: Tube Kit ((1 m) with Tube Flexer and Mouthpiece)
  • Page 6: Volcano Medic 2 Hot Air Generator Functional Elements

    1. PRODUCT OVERVIEW, SCOPE OF DELIVERY, SERVICE 1. PRODUCT OVERVIEW, SCOPE OF DELIVERY, SERVICE 1.2. VOLCANO MEDIC 2 Hot Air Generator Functional Elements 1.3. Scope of Delivery VOLCANO MEDIC 2 Vaporization System 1 pc. VOLCANO MEDIC 2 Hot Air Generator 1 pc.
  • Page 7: Service

    Instructions for Use for the user. VOLCANO MEDIC 2 Vaporization Tel.: +49-74 61-96 97 07-0 · e-mail: info@vapormed.com These instructions given in this In- System on www.vapormed.com For repairs, warranty claims, or disposal, please send the device to the...
  • Page 8 Safety tested and production monitored by TUEV SUED Product Service GmbH according to IEC 60601-1. Caution! Hot surfaces! Never leave Filling Chamber on VOLCANO MEDIC 2 Hot Air Generator. Protect from direct sunlight. Protect against moisture and humidity.
  • Page 9: Warnings

    2 . E X P L A N AT I O N O F S Y M B O L S , WA N R I N G S A N D 2 . E X P L A N AT I O N O F S Y M B O L S , WA N R I N G S A N D S A F E T Y R E C O M M E N D AT I O N S S A F E T Y R E C O M M E N D AT I O N S or dissolved in an alcohol solu-...
  • Page 10: Intended Use

    3 . I N T E N D E D U S E S A F E T Y R E C O M M E N D AT I O N S The VOLCANO MEDIC 2 Vaporization System is intended for vaporizing and...
  • Page 11: Important Remarks

    VOLCANO MEDIC 2 Vaporiza- The application and inhalation are Use only dronabinol (THC) or me- tion System. described in Chapters 6.2. and 7.3.
  • Page 12: Operating Conditions

    Do not store or transport any parts of mains supply data. pression acc. to EN 60601-1-2 (see the VOLCANO MEDIC 2 Vaporization All parts of the electrical system must Chapter 10. “Hot Air Generator”, page System in direct sunlight, wet rooms comply with currently applicable offi- 57).
  • Page 13: Commissioning

    5 . T H E VOLCA NO M E DIC 2 H O T A I R G E N E R AT O R 5 . T H E VOLCA NO M E DIC 2 H O T A I R G E N E R AT O R 5.4.
  • Page 14: Keys Combination

    The Drip Pad is inserted in the Filling prescription (generally 2.5% THC) for Chamber instead of the lower Screen. Key command Result inhalation with the VOLCANO MEDIC 2 Vaporization System. Press the touch button Switching on the heating ‚HEAT‘ 6.1. Preparation...
  • Page 15 6 . T H E U S E O F D R O N A B I N O L 6 . T H E U S E O F D R O N A B I N O L The Dosing Capsule Adapter, Please make sure to not over- available as an accessory, is...
  • Page 16: Medic Valve Balloon

    6 . T H E U S E O F D R O N A B I N O L 6 . T H E U S E O F D R O N A B I N O L 6.2.
  • Page 17: Inhalation

    Press Mouthpiece against lips to inhale dense on the interior surface of the VOLCANO MEDIC 2 when the heater is Balloon in time (a few hours). switched on – except for separating...
  • Page 18: Application Part: Tube Kit

    6 . T H E U S E O F D R O N A B I N O L 6 . T H E U S E O F D R O N A B I N O L Slowly inhale the vapor from the Tube 6.3.
  • Page 19: The Efficiency Of Cannabinoids Vaporized From Hemp Flowers (Cannabis Flos)

    7. T H E U S E O F H E M P F L O W E R S 7. T H E U S E O F H E M P F L O W E R S Use only standardized, medicinal temperatures cause a lower can- 7.2.
  • Page 20: Medic Valve Balloon

    7. T H E U S E O F H E M P F L O W E R S 7. T H E U S E O F H E M P F L O W E R S Take care that the Screens are 7.3.
  • Page 21: Application

    Do not leave the Filling Cham- The Valve Balloon will now fill with the ber on the hot air outlet of the cannabis aerosol. VOLCANO MEDIC 2 when the heat is Remove Valve Balloon with Filling Chamber switched on – except for filling the Valve Balloon. Caution! Hot surface!
  • Page 22: Inhalation

    7. T H E U S E O F H E M P F L O W E R S 7. T H E U S E O F H E M P F L O W E R S 7.3.2.
  • Page 23: Application Part: Tube Kit

    Do not leave the Filling Chamber on the card the used plant material. with Cap on the Hot Air Generator and hot air outlet of the VOLCANO MEDIC 2 rotate clockwise as far as possible. Put when the heat is switched on – except the Tube Kit on the Filling Chamber and for inhalation from the Tube Unit.
  • Page 24: Dosing Capsules

    8. DO S I N G CA P S U L E S 8. DO S I N G CA P S U L E S 8.1.1. Filling the Dosing Capsules 8.1. Dosing Capsules with ground Hemp Flowers (for single use) and Magazin Currently, patients in practically all countries, which allow the use of hemp flowers for medical purposes, get a...
  • Page 25: Inserting The Dosing Capsules

    First, the Dosing Capsule Adapter, that If the VOLCANO MEDIC 2 Vaporization age bacterial growth. Please note is available as an accessory as well, The Filling Set for 40 Dosing Capsules System is to be used by other people Chapter 9.2.
  • Page 26: Filling Chamber As Well As Tube Flexer And Mouthpiece Of The Tube Kit

    9. H Y G I E N E 9. H Y G I E N E phenol derivatives, amin com- day straight after the last applica- Possible alternative: alternatively, all Use a soft brush (bottle brush) pounds (in high concentrations) tion.
  • Page 27: Inspecting/Maintenance

    9. H Y G I E N E 9. H Y G I E N E 9.3.6. Reusability of the Valve 9.4. Disassembly and Assembly of 9.4.2. Disassembly of the Filling 9.3.3. Inspecting/Maintenance Balloon and/or Tube the Filling Chamber Chamber Cap After the cleaning, check all individual parts for surface damage, cracks, sof- Use, e.g., the handle of the Cleaning...
  • Page 28: Disassembly Of The Filling Chamber

    9. H Y G I E N E 9. H Y G I E N E The upper Screen has to be 9.4.3. Disassembly of the Filling 9.4.5. Assembly of the Filling Lower Screen placed carefully into the in- Chamber Chamber Cap tended notch.
  • Page 29: Disassembly And Assembly Of The Tube Kit

    9. H Y G I E N E 10. H O T A I R G E N E R AT O R 9.5.2. Drying 10.1. Cleaning If a cleaning spray is being 9.5. Disassembly and Assembly of used, it should be applied the Tube Kit The Tube Flexer and Mouthpiece must Before maintenance, the device has...
  • Page 30: Storage

    If the Hot Air Generator is irreparably be activated. internal fuse may have been triggered. damaged, please do not simply throw In this case, send the VOLCANO MEDIC 2 Hot Air it away. Generator to our Service Center. As it is made of high quality, complete-...
  • Page 31: Technical Specifications Of The Volcano Medic

    110-120 V / 50-60 Hz) In Grubenäcker 5-9, The voltage specification is located 78532 Tuttlingen, Germany on the bottom side of the VOLCANO MEDIC 2 Hot Air Generator. Power consumption: 270 VA Air pump output: 10 VA Air temperature: adjustable between approx. 40 - 210°C (104 - 410°F) Air flow: approx. 12 l/min...
  • Page 32: Essential Performance

    30 %. Emission test Emissions test Compliance Electromagnetic environment - Guidance Group 1 RF emissions The VOLCANO MEDIC 2 Vaporization Electrical fast 5/50 ns, 5/50 ns, Mains power quality CISPR 11 System uses RF energy only for its internal transient/burst 100 kHz, ±2 kV...
  • Page 33 30 cm (12 inches) 80 % AM at 1 80 % AM at 1 recommended that the to any part of the VOLCANO MEDIC 2 VOLCANO MEDIC 2 Vaporization System is Vaporization System, operated from an including cables, speci- uninterruptible power fied by the manufacturer.
  • Page 34: Spare Parts And Accessories

    REF 01 01 M VOLCANO MEDIC 2 Immunity test Compliance Electromagnetic (1 pc. VOLCANO MEDIC 2 Hot Air Generator, 1 pc. Power Cord, IEC 60601 test level level environment – Guidance 4 pcs. MEDIC VALVE Balloon with Mouthpiece, 1 pc. Tube System, 1 pc.
  • Page 35 Cleaning Brush Set (3 pcs. Cleaning Brush) (1 pc. Magazine, 8 pcs. Dosing Capsule) REF 09 33 M Dosing Capsule Set, 40 pcs. All spare parts and accessories) may be ordered from www.vapormed.com. REF 09 34 M Dosing Capsule Set, 400 pcs. REF 09 40 Capsule Caddy (1 pc.
  • Page 36: Compliance With Legal And Normative Requirements

    In addition, we guar- Please send the complete defective Storz & Bickel GmbH & Co. KG TÜV SÜD Product Service GmbH antee that the VOLCANO MEDIC 2 will item to us, not disassembled, with in- Ridlerstrasse 65 In Grubenäcker 5-9, be free from defects for a period of voice.
  • Page 37: Repair Service

    13. WARR ANT Y, LIABILIT Y, REPAIR SERVICE 13.3. Repair Service In addition to our warranty obligations, we offer competent repair service to our customers. We will promptly repair any defective products made by us after we have informed the customer of estimated costs and obtained cus- tomer approval.