  • Page 1 INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions.
  • Page 2: Table Of Contents

    3. Intended Use ................13 4. Important Remarks ..............14 4.1. Operating Conditions, ........... 16 4.2. Storage and Transport Conditions ....... 16 5. The VOLCANO MEDIC Hot Air Generator ......17 5.1. Unpacking ..............17 5.2. Installation ..............17 5.3. Operation ..............17 5.4.
  • Page 3 INSTRUCTIONS FOR USE ENGLISH INSTRUCTIONS FOR USE ENGLISH Table of Contents Table of Contents ............Page ............Page 7. The Use of Hemp Flowers (Cannabis Flos) ......27 10. Hot Air Generator ..............45 7.1. The Efficiency of Cannabinoids vaporized 10.1.
  • Page 4: Product Overview, Scope Of Delivery, Service

    1. PRODUCT OVERVIEW, SCOPE OF DELIVERY, SERVICE 1. PRODUCT OVERVIEW, SCOPE OF DELIVERY, SERVICE Product Overview Delivery includes VOLCANO MEDIC Vaporization System: 1 pc. VOLCANO MEDIC Hot Air Generator Hot Air Outlet 1 pc. Herb Mill (not shown) Actual Temperature 1 pc.
  • Page 5: Explanation Of Symbols, Safety Recommendations

    VOLCANO MEDIC Vaporization These instructions given in this In- Tel.: +49-74 61-96 97 07-0 · e-mail: info@vapormed.com System on www.vapormed.com structions for Use must be strictly For repairs, warranty claims, or disposal, please send the device to the observed as they are extremely following address: Storz &...
  • Page 6 Therefore, make Caution! Hot surfaces! devices that are connected. sure that you always keep the Hot Air Never leave Filling Chamber on the VOLCANO MEDIC Hot Air If you have any concerns, ask a Generator and accessories out of the Generator.
  • Page 7: Intended Use

    The VOLCANO MEDIC Vaporization Do not put any objects into the open- The Hot Air Generator must not be System is intended for vaporizing ings of the device.
  • Page 8: Important Remarks

    4. IMPORTANT REMARKS 4. IMPORTANT REMARKS The VOLCANO MEDIC Va- At a certain dosage, cannabis For application, a distinction must be porization System ensures have psychotropic made between the vaporization of the highly effective, safe, and (mind-altering) effect. dronabinol (THC) dissolved in alcohol...
  • Page 9: Operating Conditions

    Do not store or transport any parts of Before installing the Hot Air Gen- Allow the device to cool down before it pression acc. to EN 60601-1-2 (see the VOLCANO MEDIC Vaporization erator make sure that the information is packed away. Chapter 10. “Hot Air Generator”, page...
  • Page 10: Commissioning

    5. THE VOLCANO MED IC HOT AIR GENER ATOR 5. THE VOLCANO MED IC HOT AIR GENER ATOR 5.4. Commissioning 5.6. Temperature Setting shows the actual temperature in the Filling Chamber with the air pump Do not leave the device unat- switched on, and the lower, green tended while it is being opera- Actual temperature...
  • Page 11: The Use Of Dronabinol (Thc)

    (see Chapter 9.3. “Disposable MED- prescription (generally 2.5% THC) for nol is approximately 40%. IC VALVE Lip Piece for Hygienic Use”, 6.3. Application inhalation with the VOLCANO MEDIC page 39) For comparison: The systemic bio- Turn the Filling Chamber upside down Vaporization System.
  • Page 12 6. THE USE OF DRONABINOL 6. THE USE OF DRONABINOL Please make sure to not overfill the and then the Valve Balloon on and al- Liquid Pad. It can contain up to 5 low them to click in place. This opens drops.
  • Page 13: Inhalation From The Valve Balloon

    6. THE USE OF DRONABINOL 6. THE USE OF DRONABINOL 6.4. Inhalation from the When the Valve Balloon is filled, press so, the Valve opens and the aerosol the “AIR” button and shut off the air Valve Balloon can be inhaled from the Valve Balloon. pump and remove the Valve Balloon Attach the Mouthpiece with attached As soon as you remove the pressure...
  • Page 14: The Use Of Hemp Flowers (Cannabis Flos)

    6. THE USE OF DRONABINOL 7. THE USE OF HEMP FLOWERS Breathing Technique Use only standardized, medicinal Temperature - Higher vaporiza- hemp flowers (cannabis flos) that tion temperatures cause a higher Inhale only half as much as possible. have been tested by licensed produc- cannbinoid concentration in the Hold your breath a few seconds and ers for authenticity, purity, and patho-...
  • Page 15 7. THE USE OF HEMP FLOWERS 7. THE USE OF HEMP FLOWERS When observing the Instructions for Use and with a vaporization temperature of 210°C (410°F) the following reference values are validated in studies: Cannabinoid concentration per Balloon Filling at 185°C (365°F) with 500 mg filling quantity Drug (Filling Cannabinoid Cannabinoid con-...
  • Page 16: Preparation

    7. THE USE OF HEMP FLOWERS 7. THE USE OF HEMP FLOWERS 7.2. Preparation For consistent and reproduci- Take care that the Screens ture is equal to the set temperature ble dosage with e. g. 100 mg, are not obstructed with plant put the Filling Chamber with Cap on Make sure to use the Mouth- use each Filling Chamber...
  • Page 17: Inhalation From The Valve Balloon

    7. THE USE OF HEMP FLOWERS 7. THE USE OF HEMP FLOWERS 7.4. Inhalation from the Valve When the Valve Balloon is filled, As soon as you remove the pressure switch off the air pump and remove Balloon from the Mouthpiece, the Valve auto- the Valve Balloon together with the matically closes.
  • Page 18: Accessories: Dosing Capsules And Magazine

    7. THE USE OF HEMP FLOWERS 8. ACCESSORIES: DOSING CAPSULES AND MAGAZINE Breathing Technique When the content of the Valve ground and have to be portioned and Balloon is almost emptied, weight out by the patient according Inhale only half as much air as pos- you can empty the Balloon to the doctor‘s directive.
  • Page 19: Filling The Dosing Capsules With Dronabinol

    8. ACCESSORIES: DOSING CAPSULES AND MAGAZINE 8. ACCESSORIES: DOSING CAPSULES AND MAGAZINE 8.3. Inserting the Dosing Capsules First, the Filling Chamber Reducer, that is available as an accessory as well, is to be inserted instead of the Filling Chamber Cylinder (see Chapter 9.5.
  • Page 20: Hygiene

    VOLCANO MEDIC Vaporiza- The Lip Piece is equipped piece, slid until stop and is then ready tion System The VOLCANO MEDIC Vaporization with a check valve. This for operation. System is intended for multiple use. Please ensure that the Mouthpiece,...
  • Page 21: Filling Chamber And Valve Balloon

    9. HYGIENE 9. HYGIENE 9.4. Filling Chamber and Valve Allow the liquid inside to run out Put the component parts of The Filling Chamber must be cleaned: Balloon completely and shake any remain- the Filling Chamber in a suit- if there is residue (condensate) on ing water out of the parts.
  • Page 22: Disassembly And Assembly

    9. HYGIENE 9. HYGIENE Storage Disassembling the Filling Cham- Disassembling the Filling Chamber Drying ber Cap Store Filling Chamber, Mouthpiece, Lip Push the lower Screen or the Liquid All component parts of the Filling Piece and Valve Balloon in a dry, dust- Use, e.g., the handle of the Cleaning Pad upwards out of the Filling Cham- Chamber must be completely dry be-...
  • Page 23: Hot Air Generator

    9. HYGIENE 10. HOT AIR GENER ATOR 10.1. Cleaning 10.2. Care and Maintenance Filling Chamber Cap Ring Cylinder Before any maintenance work is done, Before maintenance, the device has Filling to be switched off and the power plug the device has to be switched off and Chamber has to be unplugged.
  • Page 24: Storage

    If there are any faults in the electron- In this case, send the VOLCANO MEDIC Hot Air Generator ics of the Hot Air Generator VOLCA- to our Service Center. NO MEDIC, you can perform a reset by pulling out the power plug and No aerosol is formed.
  • Page 25: Periodic Safety Checks

    Do not try to remedy the defect your- Hot Air Generator. The VOLCANO MEDIC Vaporization System is intended for use in the electro- self. Contact directly our Service magnetic environment specified below. The customer or the user of the VOL- Power consumption: 120 VA Center.
  • Page 26 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity test level level environment – guidance The VOLCANO MEDIC Vaporization System is intended for use in the electro- magnetic environment specified below. The customer or the user of the VOL- Voltage dips, <5 % Uτ...
  • Page 27 – guidance The VOLCANO MEDIC Vaporization System is intended for use in the electro- magnetic environment specified below. The customer or the user of the VOL- Where P is the maximum CANO MEDIC Vaporization System should assure that it is used in such an en- output power rating of the vironment.
  • Page 28 RF disturbances are controlled. The customer flection from structures, objects and or the user of the VOLCANO MEDIC Hot Air Generator can help prevent electro- people. magnetic interference by maintaining a minimum distance between portable and...
  • Page 29: Spare Parts And Accessories

    11. SPARE PARTS / ACCESSORIES 12. DECL AR ATION OF CE CONFORMIT Y The devices fulfill the requirements of the following directives and standards: REF 01 00 M ........VOLCANO MEDIC Vaporization System Medical products: 93/42/EWG UL medical safety testing: REF 05 01 M ...........
  • Page 30: Warranty, Liability, Repair Service

    13. WARR ANT Y, LIABILIT Y, REPAIR SERVICE 13. WARRANTY, LIABILITY, REPAIR SERVICE Warranty Repair Service Storz & Bickel GmbH & Co. KG as covered to warranty law through re- In addition to our warranty obligations, seller hereby guarantees the cus- pair or by delivering a new product to we offer competent repair service to tomer that the product will be free...
  • Page 31: Proof Of The Annual Safety Checks

    13. WARRANTY, LIABILITY, REPAIR SERVICE 14. PROOF OF THE ANNUAL SAFET Y CHECKS ( SC ) Date SC Finding Comments Signature Name / Title not OK not OK not OK not OK not OK not OK not OK not OK not OK not OK not OK...
  • Page 32 Manufacturer and Distributor: STORZ & BICKEL GMBH & CO. KG In Grubenäcker 5-9 · 78532 Tuttlingen/Germany Phone +49-7461-969707-0 · Fax +49-7461-969707-7 E-Mail: info@vapormed.com...