Figure 59. Yellow/Green/Blue Wire To Connect To R52, The 25K Rit Pot In The Color Order Shown; Figure 60. Connect The 25K Rit Pot To The R52 Header In The Color Order Shown. Also Attach A Spdt - NORCAL NC2030 Manual

Low power, high performance 20m or 30m dc transceiver
Table of Contents

Advertisement

L5 - 6.8 uH
X1 - 13.065 MHz Crystal
Attach R52 (25K panel mounted pot) to the front panel RIT control, and connect to the R52 connections
on the board. Use 3" of Yellow/Green/Blue ribbon wire to make this connection. The 25K should have
a center detent position, which is where the RIT control is normally set. As the 25K pot is tuned across
its entire range, check for the center detent.
see update below

Figure 59. Yellow/Green/Blue wire to connect to R52, the 25k RIT pot in the color order shown (

).
Update: the RIT pot in figure 59 above seems to tune backwards. To fix
this, reverse the yellow and blue wires from that shown above.
Use one of the two SPST panel mounted switches to connect to the S1 connections on the board.
Connect using 3" of the Grey-Violet pair as shown.
Figure 60. Connect the 25K RIT pot to the R52 header in the color order shown. Also attach a SPDT switch to S1
This VXO section of the rig will be tested after the completing the next section.