Download Print this page

SMC Networks PF2W720-N04-67 Manual

Digital flow switch (integrated display type)

Advertisement

Quick Links

No.PF※※-OMO0012-E
PRODUCT NAME
Digital Flow Switch
(Integrated display type)
MODEL / Series / Product Number
PF2W7##

Advertisement

loading
Need help?

Need help?

Do you have a question about the PF2W720-N04-67 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks PF2W720-N04-67

  • Page 1 No.PF※※-OMO0012-E PRODUCT NAME Digital Flow Switch (Integrated display type) MODEL / Series / Product Number PF2W7##...
  • Page 2: Table Of Contents

    Table of Contents Safety Instructions Model Indication and How to Order Summary of Product parts Definition and terminology Mounting and Installation Installation Piping Wiring Outline of setting List of outputs Initialize mode Setting procedure of initialize mode Function selection mode F_1 Input procedure of the Set value of instantaneous output F_2 Input procedure of the Set value of instantaneous output (Auto-preset) F_3 Input procedure of the Set value of accumulated output...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
  • Page 4: Limited Warranty And Disclaimer/Compliance Requirements

    Safety Instructions Caution 1.The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 5 Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
  • Page 6 Caution ■Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result. ■Do not touch the piping or its connected parts when the fluid is at high temperature. It may lead to burnt.
  • Page 7 ●Product handling Installation Tighten to the specified tightening torque. If the tightening torque is exceeded the mounting screws and brackets may damaged. If the tightening torque is insufficient, the product may be displaced and the mounting screws may come loose. (Refer to page "Mounting and Installation".) Ensure that the FG terminal is connected to ground when using a commercially available switch-mode...
  • Page 8 Wiring Do not pull the lead wires. In particular, never lift a product equipped with fitting and piping by holding the lead wires. Otherwise damage to the internal parts can result, causing malfunction or disconnection of the connector. Avoid repeatedly bending or stretching the lead wire, or placing heavy loads on it. Repeated bending stress or tensile stress can cause damage to the sheath, or breakage of the wires.
  • Page 9 Environment Do not use the product in an environment that is constantly exposed to the splash of water. Otherwise failure or malfunction can result. Take measures such as using a cover. Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result.
  • Page 10 Adjustment and Operation Connect load before turning on the power. Do not short-circuit the load. Although an error is displayed when the product load is short circuited, excess current may cause damage to the product. Do not press the setting buttons with a sharp pointed object. This may damage the setting buttons.
  • Page 11: Model Indication And How To Order

    Model indication and How to Order -10- No.PF※※-OMO0012-E...
  • Page 12 Lead wire with lead wire and connector without lead wire (Straight, 3 m) : Lead wire is not assembled with the product, but shipped together. Made to order Model indication Content Page PF2W7 -28 - -X560 Output specification: NPN (1 output) + Analogue (1 to 5 V) PF2W7 -29 - -X560 Output specification: NPN (1 output) + Analogue (4 to 20 mA)
  • Page 13: Summary Of Product Parts

    Summary of Product parts Body Connector pin numbers (On the product) DC(+) OUT2 DC(-) OUT1 Item Description Monitor part See below. Piping port Connected to the fluid inlet at IN side and to the fluid outlet at OUT side. Body The body of the product.
  • Page 14: Definition And Terminology

    ■Definition and terminology Terms Meaning The total amount of fluid that has passed through the device. If an instantaneous flow of Accumulated flow 10 L/min continues for 5 minutes, the accumulated flow will be 10 x 5 = 50 L. Accumulated pulse A type of output where a pulse is generated every time a predefined accumulated flow output...
  • Page 15 Terms Meaning Part in contact with A part that comes into physical contact with the fluid. fluid Pressure The amount of variation in the analogue output or display value when the supply characteristics pressure is changed. Proof pressure The pressure beyond which the flow switch will be damaged. Rated flow range The flow range within which the product will meet all published specifications.
  • Page 16: Mounting And Installation

    Mounting and Installation ■Installation Never mount the product in a location that will be used as a foothold. The rotation angle of the monitor is 270 , in steps of 90 . Rotating the display part with excessive force will damage the end stop.
  • Page 17: Piping

    ■Piping Use the product within the specified operating pressure range and temperature range. Proof pressure is 1.5 MPa. Connect the piping to the fittings. Mount the product so that the fluid direction is the same as the arrow indicated on the product. Never mount the product upside down.
  • Page 18 ●Connecting the piping Ensure that the metal piping attachments are tightened to the required torque (refer to the table below). If the tightening torque is exceeded, the product can be broken. If the tightening torque is insufficient, the fittings may become loose. When connecting piping to the product, a spanner should be used on the metal piping attachment only.
  • Page 19: Wiring

    ■Wiring Connections should only be made with the power supply turned off. Use separate routes for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise. Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply.
  • Page 20 ●Internal circuit and wiring example When the lead wire with connector designated for the PF2W7 is used, the wire colours will apply as shown in the diagram. NPN (2 outputs) type PF2W7 -27 - Max. 30 V, 80 mA Internal voltage drop: 1 V or less PNP (2 outputs) type PF2W7 -67 -...
  • Page 21: Outline Of Setting

    Outline of setting Power is supplied The output will not operate for 3 seconds after supplying power. The identification code of the product is displayed. Measurement mode The mode in which the flow is detected and displayed, and the switch function is operating. This is the basic operating mode;...
  • Page 22: List Of Outputs

    ■List of outputs Find the diagram of the output required in the table below. Perform settings following the Set value column on the right. Characters in ( ) are for OUT2. Switch Switch output diagram Output mode Set value operation Set point 2 Set point 1 2z...
  • Page 23: Initialize Mode

    Initialize mode ●Default settings Item Default settings Page Selection of display mode [d_1] Display instantaneous flow  Unit selection function [U_1] L/min Page Selection of output mode (OUT1) [o10] Instantaneous output mode Selection of output mode (OUT2) [o20] Instantaneous output mode Selection of switch operation (OUT1) [1_n] Reverse output Page...
  • Page 24: Setting Procedure Of Initialize Mode

    ■Setting procedure of initialize mode <Operation> Press the button for 2 seconds or longer during measurement mode. Selection of display mode Select the display of instantaneous flow or accumulated flow. Press the button to select. [d_1]: display instantaneous flow [d_2]: display accumulated flow The product with unit selection function Press the button.
  • Page 25 Selection of switch operation (OUT1) Select the switch operation required referring to the list of outputs (page 21). Press the button to select. [1_n]: Reverse output [1_P]: Non-Reverse output Press the button. Selection of switch operation (OUT2) Select the switch operation required referring to the list of outputs (page 21). Press the button to select.
  • Page 26 Flow specification when [U_2] is selected by the unit selection function Model PF2W704(T) PF2W720(T) PF2W740(T) PF2W711 0.13 to 1.06 0.55 to 4.25 1.3 to 10.6 2.6 to 26.4 Rated flow range gal(US)/min gal(US)/min gal(US)/min gal(US)/min Setting/display flow 0.10 to 1.16 0.40 to 4.75 1.0 to 11.6 2.0 to 28.4...
  • Page 27: Function Selection Mode

    Function selection mode Function selection mode In measurement mode, press the button, to display [F_ ]. This [F_ ] indicates the mode for changing each functional setting. : When OUT1 or OUT2 is assigned to be instantaneous output mode during initialize mode, [F_1] and [F_2] are displayed. When OUT1 or OUT2 is assigned to be accumulated output mode, [F_3] is displayed.
  • Page 28: F_1 Input Procedure Of The Set Value Of Instantaneous Output

    ■[F_1] Input procedure of the Set value of instantaneous output The Set point of the switch output can be set manually. <Operation> Press the button in function selection mode to display [F_1]. (When OUT1 or OUT2 is assigned to be accumulated output mode, [F_3] is displayed.) Press the button.
  • Page 29: F_2 Input Procedure Of The Set Value Of Instantaneous Output (Auto-Preset)

    ■[F_2] Input procedure of the Set value of instantaneous output (Auto-preset) The Set point of the switch output can be automatically set referring to actual air flow. <Operation> Press the button in function selection mode to display [F_2]. (When OUT1 or OUT2 is assigned to be accumulated output mode, [F_2] is displayed.) Press the button.
  • Page 30: F_3 Input Procedure Of The Set Value Of Accumulated Output

    ■[F_3] Input procedure of the Set value of accumulated output The Set point of the switch output can be manually set. Accumulated flow rate is displayed by the lower 3 digits and upper 3 digits separately. Setting is performed separately. <Operation>...
  • Page 31 [F_3] Input procedure of the Set value of accumulated output is completed. Return to measurement mode. Starting of accumulation Check that the display of accumulated flow rate is selected as the display mode. Press the buttons simultaneously in measurement mode. [-] flashes and accumulation starts.
  • Page 32: Key-Lock Function

    Key-lock function This function is used to prevent errors occurring due to unintentional changes of the Set values. <Operation - How to lock> 1. Press the button for 3 seconds or longer in measurement mode. The display will change from [F_ ] to [d_ ] to [unL].
  • Page 33: Maintenance

    Maintenance How to reset the product after a power cut or forcible de-energizing The setting of the product will be retained as it was before a power cut or de-energizing. The output condition is also basically recovered to that before a power cut or de-energizing, but may change depending on the operating environment.
  • Page 34: Troubleshooting

    Troubleshooting Troubleshooting If an operation failure occurs with the product, use the table below to find out the cause of the problem. If none of the countermeasures seem to be applicable, or a replacement product operates normally when installed, the product may be faulty. A product can be damaged by the operating environment (system configuration etc).
  • Page 35 Fault Probable cause Recommended action Wiring failure. Correct the wiring. There is no output. Connector loose. Check the connector. Set up filter (approx.40 mesh) at IN side of product. Foreign matter inside. If there is foreign matter stuck to the mesh, remove it completely, taking care not to damage the product.
  • Page 36: Error Indication

    ■Error indication Error Name Error Display Error Type Troubleshooting Method Excessive Flow has exceeded the upper limit of the Reduce the flow. instantaneous flow display flow range. OUT1 The switch output load current is more over current error than 80 mA (OUT1). Turn the power off and remove the cause of the over current.
  • Page 37: Specification

    Specification ■Specifications Model PF2W704(T) PF2W720(T) PF2W740(T) PF2W711 1 Water and ethylene glycol solution (viscosity of 3 mPa・s (3 cP) or less) Applicable fluid 0 to 50 C Without T: 0 to 50 C (no condensation or freezing) Fluid temperature (no condensation With T: 0 to 90 C (no condensation or freezing) or freezing) 0.5 to 4.0...
  • Page 38 Model PF2W704(T) PF2W720(T) PF2W740(T) PF2W711 Enclosure IP65 Operation: 0 to 50 C, Storage: -25 to 85 C (no condensation or freezing) Operating temperature range Operation, Storage: 35 to 85%R.H. (no condensation) Operating humidity range ±5%F.S. max. (0 to 90 C, 25 C reference) Temperature characteristics Withstand voltage 1000 VAC, for 1 minute between the external terminals and case...
  • Page 39: Characteristics Data

    ■Characteristics data ●Flow characteristics (pressure loss) Model Graph a (L/min) b (L/min) PF2W704(T) PF2W720(T) PF2W740(T) PF2W711 ●Measurable range of ethylene glycol aqueous solution (Reference value) : The product with operating fluid temperature specification [0 to 50 C] is not suitable for fluids with a temperature greater than 50 -38- No.PF※※-OMO0012-E...
  • Page 40: Dimensions

    ■Dimensions (in mm) PF2W704/720 Model PF2W704 100 mm PF2W720 106 mm -39- No.PF※※-OMO0012-E...
  • Page 41 PF2W740 -40- No.PF※※-OMO0012-E...
  • Page 42 PF2W711 -41- No.PF※※-OMO0012-E...
  • Page 43 PF2W704T/720T/740T -42- No.PF※※-OMO0012-E...
  • Page 44 Lead wire and connector (Straight): ZS-37-A Lead wire and connector (Right angle): ZS-37-B Dimensions of rotating monitor part -43- No.PF※※-OMO0012-E...
  • Page 45 Bracket (PF2W704/720): ZS-29-T Bracket (PF2W740/7 T): ZS-29-V Bracket (PF2W711): ZS-29-W -44- No.PF※※-OMO0012-E...
  • Page 46: Made To Order

    Made to Order ●Model Indication and How to Order Refer to page for details of model indication and how to order. ●Internal circuit and wiring example When the lead wire with connector designated for PF2W7 is used, the wire colours will apply as shown on the circuit diagram.
  • Page 47 ●Specifications PF2W7 -28 - -X560 PF2W7 -29 - -X560 Model PF2W7 -68 - -X560 PF2W7 -69 - -X560 Voltage output (1 to 5 V) Current output (4 to 20 mA) Load impedance Output impedance Power supply voltage 12 V: 300 Ω Impedance Analogue approx.
  • Page 48 Revision history A: Contents revised in several places. B: Revision. (kPa  MPa (page 38)) C: Contents revised in several places. D: Contents revised in several places. [July 2018] E: Revision. [January 2019] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.