Air Supply And Ventilation - Dean D20 Series Installation & Operation Manual

Decathlon series gas fryers (non-ce)
Table of Contents

Advertisement

2.5 Pre-Installation (cont.)
C. Installation Standards
1. U.S. installations must meet:
American National Standard Institute
ANSI Z83.11
American Gas Association
8501 E. Pleasant Valley Road
Cleveland, OH 44131
National Electrical Code
ANSI/NFPA #70
American National Standard Institute
1430 Broadway
New York, NY 10018
NFPA Standards #96 and #211
National Fire Protection Association
470 Atlantic Avenue
Boston, MA 02110

2.6 Air Supply and Ventilation

This appliance must be installed with sufficient ventilation to prevent the occurrence
of unacceptable concentrations of substances harmful to the health of personnel in
Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow as
well as for service and maintenance.
A. Do not connect this fryer to an exhaust duct.
B. Correct installation and adjustment will ensure adequate airflow to the fryer system.
C. A commercial, heavy-duty fryer must vent its combustion wastes to the outside of the
building. A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan
must be provided in the wall above the unit, as exhaust gas temperatures are approximately
800-1000°F (427-538°C). Check air movement during installation. Strong exhaust fans in
the exhaust hood or in the overall air conditioning system can produce slight air drafts in the
room.
DECATHLON SERIES GAS FRYERS (NON-CE)
CHAPTER 2: IMPORTANT INFORMATION
the room in which it is installed.
2. Canadian installations must meet:
CAN 1-B149 Installation Codes
Canadian Gas Association
55 Scarsdale Road
Don Mills, ONT, M3B 2R3
Canadian Electric Code c22.1, part 1
Canadian Standards Association
178 Rexdale Blvd.
Rexdale, ONT, M9W 1R3
DANGER