Air Supply And Ventilation - Dean D20 Series Installation & Operation Manual

Decathlon series gas fryers
Table of Contents

Advertisement

2.5 Pre-Installation (cont.)
3.
Combustible construction with a minimum clearance of 15-cm (6-inch) side and 15-cm (6-
inch) rear, and equipped with factory-supplied 15-cm (6-inch) adjustable legs or 13-cm (5-
inch) casters.
Local building codes prohibit a fryer with its open tank of hot oil from being installed
beside an open flame of any type, including those of broilers and ranges.
C. Installation Standards
1. CE/EXPORT STANDARDS: Fryer installation must conform with local codes, or in the absence
of local codes, to the appropriate national or European Community (CE) standards.

2.6 Air Supply and Ventilation

This appliance must be installed with sufficient ventilation to prevent the occurrence
of unacceptable concentrations of substances harmful to the health of personnel in
Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow as
well as for service and maintenance.
A. Do not connect this fryer to an exhaust duct.
B. Correct installation and adjustment will ensure adequate airflow to the fryer system.
C. A commercial, heavy-duty fryer must vent its combustion wastes to the outside of the
building. A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan
must be provided in the wall above the unit, as exhaust gas temperatures are approximately
427-538°C (800-1000°F). Check air movement during installation. Strong exhaust fans in
the exhaust hood or in the overall air conditioning system can produce slight air drafts in the
room.
D. Do not place the fryer's flue outlet directly into the plenum of the hood, as it will affect the
gas combustion of the fryer.
E. Never use the interior of the fryer cabinet for storage or store items on shelving over or
behind the fryer. Exhaust temperatures can exceed 427ºC (800°F) and may damage or melt
items stored in or near the fryer.
DECATHLON SERIES GAS FRYERS (CE)
CHAPTER 2: IMPORTANT INFORMATION
DANGER
DANGER
the room in which it is installed.
2-4