4.8 Command Menu

INPUT 1 ACTION (function input 1)
This parameter determines the control function of the input "Ctrl. In 1."
(s) = stat. switching characteristics (level modulation)  INPUT CONFIG must be
set to ACTIVE LOW/HIGH.
(d) = dyn. switching characteristics (edge modulation)  INPUT CONFIG must
be set to RISING/FALLING EDGE.
Value Designation
0
1
2
3
4
44
S
OS6.0
PERATING
OFTWARE
DATASTABLE &
/ERROR
/DATASTABLE
& ERROR
/DATASTABLE
& /ERROR
DATASTABLE &
/DATASTABLE
NO
RESET/SET
VALUE
FREEZE
SSI ZERO
POSITION
RESET/SET
COUNTER A
Function
Pin 25 : Datastable output (Active High)
Pin 24: Error output (Active Low)
Pin 25 : Datastable output (Active Low)
Pin 24: Error output (Active High)
Pin 25 : Datastable output (Active Low)
Pin 24: Error output (Active Low)
Pin 25 : Datastable output (Active High)
Pin 24: Datastable output (Active Low)
Function
No function.
Mode "SSI": Transfer of the currently
detected position value (after bit
suppression and possibly performed
encoder zero offset shift) into the
parameter "SSI offset" (display offset)
Mode "Counter": Reset / set of both
counter values (channel A and B) to the set
values in SET VALUE A u. B
Mode "Start/Stop": Power-failure-proof
stored transfer of the current position or
angle measurement to the "Offset"
parameter.
Freezing of the current measurement
result / of the parallel output
Mode "SSI": Transfer of the current SSI
position to the "SSI-Zero" parameter
(encoder zero offset).
Mode "Counter": Reset / Set the counter
value of channel A to the set value in SET
VALUE A.
(d)
(s)
(s)
(d)
(s)
(d)
(s)