Ssi Mode - Pepperl+Fuchs K23-SSI/USB/25B-C Manual

Signal converter
Table of Contents

Advertisement

K23-SSI/USB/25B-C | O
ROUND LOOP VALUE
Defines the number of encoder steps if a concentricity function is desired. (Only
for COUNT MODE: A SINGLE and A/B x 90)
Value
0
...
99999999

4.4 SSI Mode

In this menu, the operation is defined as an absolute value converter (SSI
signals).
SSI MODE
SSI setting of the operating mode: Managing or managed
Depending on the SSI MODE, different terminals must be used for the SSI CLK:
Managing operation: Terminal X2—pins 1 and 2
Managed operation: Terminal X2—pins 5 and 6)
Value Designation
0
1
ENCODER RESOLUTION
Resolution of the SSI rotary encoder (total number of all bits)
Value
10
25
32
DATA FORMAT
Setting of the SSI code (binary or gray)
Value Designation
0
1
32
S
OS6.0
PERATING
OFTWARE
Function
No concentricity
Number of steps for the concentricity function
PRIMARY
SECONDARY
Function
Smallest value
Default value
Largest value
GRAY CODE
BINARY CODE
Function
Managing operation: Clock pulse for SSI rotary
encoder is generated by the device.
Managed operation: Clock pulse for SSI rotary
encoder comes from external control.
Function
Gray SSI code
Binary SSI code

Advertisement