K23-SSI/USB/25B-C | A
ANGLE (angle measurement)
For angle measurement, the desired position or angle output value per revolution
can be specified using the "ROUND LOOP VALUE" parameter. This output value
is generated as soon as the distance traveled (e.g., circumference), which is set
as the reference quantity in the "CIRCUMFERENCE (in mm)" parameter, is
reached. The output value then starts again at 0 until the distance traveled is
reached again. (Round Loop function!)
Using existing scaling parameters (factor, divider, and additive value), this output
value can be rescaled if desired.
Interpretation of the measurement result for the angle measurement:
The default setting ("CIRCUMFERENCE [mm] = 100,000" and "ROUND LOOP
VALUE = 360," and "FACTOR = 1," "DIVIDER = 1" and "ADDITIVE VALUE = 0")
is an angle or position output of "0 ... 360" (e.g., degrees) every 100,000 mm.
SPEED (velocity measurement)
The velocity is detected and can be converted to another unit using existing
scaling parameters (factor, divider, and additive value), if desired.
Interpretation of the measurement result for the velocity measurement:
The default setting ("FACTOR = 1," "DIVIDER = 1" and "ADDITIVE VALUE = 0")
is a velocity output in meters per second [m/s].
Note
The parallel output and the linearization function always refer to the scaled
measuring result of the selected operational mode! (Measurement_Result)