Pepperl+Fuchs K23-SSI/USB/25B-C Manual page 45

Signal converter
Table of Contents

Advertisement

Value Designation
5
RESET/SET
COUNTER B
6
LOCK COUNTER
A
7
LOCK COUNTER
B
8
RESET MIN/MAX
9
FACTORY
SETTINGS
INPUT 1 CONFIG
This parameter determines the switching characteristics for "Ctrl. In 1."
Value Designation
0
ACTIVE LOW
1
ACTIVE HIGH
2
RISING EDGE
3
FALLING EDGE
INPUT 2 ACTION
This parameter determines the control function of the input "Ctrl. In 2"
See function assignment for parameter INPUT 1 ACTION
INPUT 2 CONFIG
This parameter determines the switching characteristics for "Ctrl. In 2."
See activation assignment for parameter INPUT 1 CONFIG
INPUT 3 ACTION (FACTORY SETTINGS)
This parameter is preset to "Factory Settings" (resets device to factory settings)
and cannot be changed.
INPUT 3 CONFIG (RISING EDGE)
This parameter is preset to "Rising Edge" and cannot be changed.
K23-SSI/USB/25B-C | O
Function
Mode "Counter": Reset / Set the counter
value of channel B to the set value in SET
VALUE B.
Mode „Counter": Counter (channel A) is
locked and does not count any further
pulses as long as this command is present.
Mode „Counter": Counter (channel B) is
locked and does not count any further
pulses as long as this command is present.
Resetting the minimum / maximum value
Device is reset to factory settings (pulse
must be applied for at least one second!)
Function
Activates at "LOW" (static)
Activates at "HIGH" (static)
Activates at rising edge (dynamic)
Activates at falling edge (dynamic)
S
OS6.0
PERATING
OFTWARE
(d)
(s)
(s)
(s)
(d)
(s)
(s)
45