General Menu - Pepperl+Fuchs K23-SSI/USB/25B-C Manual

Signal converter
Table of Contents

Advertisement

K23-SSI/USB/25B-C | O
Menu

4.1 General Menu

MODE (operating mode)
This parameter defines which measurement function (operating mode/mode) the
device should fulfill.
Value
0
1
2
3
4
ENCODER PROPERTIES
This parameter defines the characteristics of the incremental input.
(Note: Only relevant for MODE: "FREQUENCY" and MODE: "COUNTER")
Value
0
1
2
3
4
22
S
OS6.0
PERATING
OFTWARE
Designation
NOT DEFINED
FREQUENCY
COUNTER
SSI
START/STOP
Designation
RS422
HTL
DIFFERENTIAL
HTL PNP
HTL NPN
TTL PNP
Parameter
P1(Y)
P2(X)
P2(Y)
...
P23(X)
P23(Y)
P24(X)
P24(Y)
Function
Operating mode: Not defined, modulation and
measurement results are zero
Operating mode: Frequency converter,
incremental signals
Operating mode: Counter, incremental signals
Operating mode: Absolute value converter, SSI
signals
Operating mode: Start/Stop interface converter
Function
RS422 standard
HTL differential
PNP (switching to +)
NPN (switching to -)
TTL PNP (switching to +)