Delta Electronics AC Motor Drive VFD-G User Manual page 68

Vfd-g series specific ac motor drives for plastic molding and air compressors machinery
Table of Contents

Advertisement

Group 10 PID Control Parameters
Parameter
Functions
10-00
Input Terminal for PID
Feedback
10-01
PID Control Detection
Signal Reference
10-02
PID Feedback Control
Method
10-03
Proportional Gain (P)
10-04
Integral Time (I)
10-05
Differential Time (D)
10-06
Upper Bound for
Integral Control
10-07
Primary Low Pass
Filter Time
10-08
PID Feedback Signal
Range
10-09
PID Feedback Signal
Fault Treatment Time
10-10
PID Feedback Signal
Fault Treatment
10-11
V/F Curve Selection
Revision July 2008, EG03, SW V1.06
Settings
00: Disabled
01: Input via AI1
02: Input via AI2
03: Input via External Reference
1.0-6550.0
00: Normal (Err=SP-FB)
01: Inverse (Err=FB-SP)
0.0~10.0
0.00~100.00 Sec
0.00~1.00 Sec
00~200%
0.0~2.5 Sec
0.01 to 10-01
0. 0~3600.0 Sec
0.0: Disabled
00: Warn and RAMP stop
01: Warn and COAST stop
02: Warn and keep operating
00: Determined by group 01
01: 1.5 power curve
02: 1.7 power curve
03: 2 power curve
04: 3 power curve
Chapter 4 Parameters|
Factory
Setting
00
1000.0
00
1.0
1.00
0.00
100
0.0
600.0
0.0
01
00
Customer
4-17

Advertisement

Table of Contents
loading

Table of Contents