MAIN DISPLAY MESSAGES

When idle, the main LCD will show the switch soft label (Name) and its IP address. If the Ring Protect feature is enabled, it
will also display status of the Ring.
If the switch has been set to Disable security features, it will show "
warning.
<Switch Name>
IP: X.X.X.X/Class
<Ring Protect Status/Security
warning if disabled>

USING THE FRONT PANEL UI

With the main screen (above) showing on the LCD, press in the encoder knob. The base configuration menu will be shown.
Turn the knob to scroll up or down the menu. The currently selected menu item is shown in
knob to enter sub-menus. Top-level menu entries are shown above.
For all menus and submenus, the current selection will be highlighted in
further options, or to select the currently selected item. If choosing from a list of options, the currently enabled option will be
shown with asterisks on either side of it, e.g.
Some menus, such as Network Settings, require the user to scroll down to accept or discard any changes made. The <Back>
option will always move the menu up one level. The current menu will time out after approximately 30 seconds.
FRONT PANEL LOCKOUT
If using Pathscape, it is possible to enable the option Front Panel Lockout, which disables the ability to make any changes
to the switch from the front panel UI. You can still navigate the menus to review settings, but cannot change any properties.
The Front Panel Lockout is temporarily disabled for 30 seconds after the switch boots up. This window allows for changes to
be made when a Pathscape connection is not available.
NOTE: It is not possible to disable the Front Panel Lockout from the front panel itself; it must be done from
Pathscape.
July 2021
Security: Disabled by User
Base Configuration
Network Setup
Device Info/Status
Advanced Settings
Admin/Security
<Back>
*
Current Property Value
PWVIA RM P12 Ethernet Switches - Manual
RACK VIA
IP: 10.30.142.169/8
Ring Protect Master: OK
White on Black
White on Black
. Push the encoder knob to reach
*
.
" as a reminder and
. Push the