If you choose Wipe All Configuration it will completely restore the device to the same state as it left the factory. This will erase
any Device Restore Point saved on the unit.
You can also choose Keep Restore Point to preserve any saved Restore Point, but be aware that the restore point could have
saved properties that are the cause of the communication loss, and recalling that restore point could cause the same issues.
The device will then reboot, having reset itself to the Factory settings. Before configuration can be restored, the unit must be
secured (either by adding to a Security Domain, or enabling Local Security).

FRONT PANEL LOCKOUT

If the device has Front Panel Lockout enabled, you will not be able to make changes from the front panel. To address this,
there is a 30-second delay before the LCD Lockout takes effect, after the switch boots up.
First, hard reboot the device (unplug and re-plug the AC power source), and then within 30 seconds after the device has
booted up, perform the above action. After 30 seconds, the front panel UI will be locked out again.
54
PWVIA RM P12 Ethernet Switches - Manual
July 2021