IQ S
ENSOR
MIQ/CHV PLUS
VALVE MODULE FOR COMPRESSED AIR-OPERATED SENSOR CLEANING HEADS
All manuals and user guides at all-guides.com
O K
e r
!
P o w
N
ET
OPERATING MANUAL
ba75539e03 03/2018

Advertisement

Table of Contents
loading

Summary of Contents for Xylem WTW MIQ/CHV PLUS

  • Page 1 All manuals and user guides at all-guides.com OPERATING MANUAL ba75539e03 03/2018 P o w IQ S ENSOR MIQ/CHV PLUS VALVE MODULE FOR COMPRESSED AIR-OPERATED SENSOR CLEANING HEADS...
  • Page 2 All manuals and user guides at all-guides.com MIQ/CHV PLUS © Copyright 2018 Xylem Analytics Germany GmbH Printed in Germany. ba75539d03 03/2018...
  • Page 3: Table Of Contents

    All manuals and user guides at all-guides.com MIQ/CHV PLUS List of contents MIQ/CHV PLUS - List of contents Overview ........5 How to use this component operating manual .
  • Page 4 All manuals and user guides at all-guides.com List of contents MIQ/CHV PLUS Accessories and options ......23 ba75539e03 03/2018...
  • Page 5: Overview

    All manuals and user guides at all-guides.com MIQ/CHV PLUS Overview Overview How to use this component operating manual Structure of the IQ Sensor Net Operating Manual IQ S ENSOR operating manual System Operating Manual (Ring Binder) Operating Operating Operating Manual Manual Manual IQ Sensor...
  • Page 6: General Characteristics

    All manuals and user guides at all-guides.com Overview MIQ/CHV PLUS General characteristics The MIQ/CHV PLUS valve module provides a switchable compressed air valve for the operation of sensor cleaning heads. The MIQ/CHV PLUS valve module registers on the IQ S system as ENSOR an output (V).
  • Page 7 All manuals and user guides at all-guides.com MIQ/CHV PLUS Overview Power supply When used in the IQ S , the valve module is supplied with voltage by ENSOR the IQ S ENSOR IQ S The MIQ/CHV PLUS can be fully integrated in the IQ S using the ENSOR ENSOR...
  • Page 8: Safety Instructions

    All manuals and user guides at all-guides.com Safety instructions MIQ/CHV PLUS Safety instructions Safety information 2.1.1 Safety information in the operating manual This operating manual provides important information on the safe operation of the product. Read this operating manual thoroughly and make yourself familiar with the product before putting it into operation or working with it.
  • Page 9: Safe Operation

    All manuals and user guides at all-guides.com MIQ/CHV PLUS Safety instructions Safe operation 2.2.1 Authorized use The authorized use of the MIQ/CHV PLUS consists of providing a control valve for compressed air-operated sensor cleaning heads in the IQ S . Only ENSOR the operation according to the instructions and technical specifications given in this operating manual is authorized (see chapter 7 T...
  • Page 10: Installation

    All manuals and user guides at all-guides.com Installation MIQ/CHV PLUS Installation Scope of delivery The following parts are included in the scope of delivery of the MIQ/CHV PLUS:  MIQ/CHV PLUS  Accessory set, including: – 2 x screwed cable glands with seals and blind plugs –...
  • Page 11 All manuals and user guides at all-guides.com MIQ/CHV PLUS Installation  Small, clamping range 4.5 to 10 mm. This cable gland is suitable for all IQ S sensor cables. ENSOR sealing ring 20 x 15 x 1 mm cable gland M16 blind plug ...
  • Page 12: Connecting The Valve Control Line

    All manuals and user guides at all-guides.com Installation MIQ/CHV PLUS Connecting the valve control line The valve control line must be connected if the valve is not controlled via the IQ S system. ENSOR General instal- Observe the following instructions when attaching connecting wires to the termi- lation instructions nal strip: ...
  • Page 13 All manuals and user guides at all-guides.com MIQ/CHV PLUS Installation Connecting the Open the module. control line to the terminal strip Valve SENSORNET 2 SENSORNET 1 Valve Fig. 3-1 Clamping termination for the valve control line Screw the cable gland (pos. 1 in Fig. 3-1) with the sealing ring (pos. 2) into the left connection opening.
  • Page 14: Connecting The Compressed Air Hoses

    All manuals and user guides at all-guides.com Installation MIQ/CHV PLUS WARNING No free wires must be allowed to project into the enclo- sure. Otherwise, there is a danger that areas safe to con- tact could come into contact with dangerous voltages. This could result in life threatening electric shock when working with the IQ S .
  • Page 15: Function Check

    All manuals and user guides at all-guides.com MIQ/CHV PLUS Installation Function check General This check is also suitable for the troubleshooting of malfunctions. instructions If the valve is not controlled via the IQ S system, the valve control line ENSOR must be connected.
  • Page 16: Settings

    All manuals and user guides at all-guides.com Settings MIQ/CHV PLUS Settings The MIQ/CHV PLUS module has a valve output. The MIQ/CHV PLUS valve module registers on the IQ S system as ENSOR a valve output (V) and appears in the list of outputs. On an IQ S terminal, you can ENSOR...
  • Page 17: Maintenance And Cleaning

    All manuals and user guides at all-guides.com MIQ/CHV PLUS Maintenance and cleaning Maintenance and cleaning Maintenance The MIQ/CHV PLUS requires no special maintenance. Cleaning The cleaning of IQ S components is described in the IQ S ENSOR ENSOR system operating manual. ba75539d03 03/2018...
  • Page 18: What To Do If

    All manuals and user guides at all-guides.com What to do if ... MIQ/CHV PLUS What to do if ... No compressed air Cause Remedy at the output – Compressed air supply inter- – Check the compressed air supply rupted or too weak –...
  • Page 19: Technical Data

    All manuals and user guides at all-guides.com MIQ/CHV PLUS Technical data Technical data General data Dimensions 144.0 52.2 Front view: Lateral view: 115.0 11.0 Rear view: 70.0 16.5 137.0 Stack mounting: Fig. 7-1 Dimension drawing of the MIQ/CHV PLUS (dimensions in mm) Mechanical Maximum number of construction...
  • Page 20 All manuals and user guides at all-guides.com Technical data MIQ/CHV PLUS Weight Approx. 0.5 kg Type of protection IP 66 (not suitable for conduit connection) Ambient Temperature conditions Operation 0 °C ... + 55 °C (32 ... 131 °F) Storage - 25 °C ...
  • Page 21: Miq/Chv Plus

    All manuals and user guides at all-guides.com MIQ/CHV PLUS Technical data MIQ/CHV PLUS Electrical data Nominal voltage Max. 24 VDC via a separate power supply module. IQ S ENSOR For details, see chapter T of the ECHNICAL DATA IQ S system operating manual ENSOR Suitable power supply modules:...
  • Page 22: Indexes

    All manuals and user guides at all-guides.com Indexes MIQ/CHV PLUS Indexes Explanation of the messages In this chapter you will find a list with all the message codes and corresponding message texts that may occur in the log book of the IQ S system for ENSOR the MIQ/CHV PLUS output module.
  • Page 23 All manuals and user guides at all-guides.com MIQ/CHV PLUS Accessories and options Accessories and options Description Model Order no. Cleaning head for online sensors with 40 mm 900 107 diameter Tubing set, comprising: CH/Epack 900 111 – 15 m compressed-air hose –...
  • Page 24 All manuals and user guides at all-guides.com Accessories and options MIQ/CHV PLUS ba75539d03 03/2018...
  • Page 25 All manuals and user guides at all-guides.com...
  • Page 26 For more information on how Xylem can help you, go to xyleminc.com. ® Service address: Xylem Analytics Germany Sales GmbH &...

Table of Contents